TEG Digital Pressure Gauges

TEG Digital Pressure Gauges
  • TEG Digital Pressure Gauges
  • TEG Digital Pressure Gauge with 7193 Pump
  • TEG Digital Pressure Gauge with 7194 Pump

Features

  • Ranges to 2500bar (37500psi)
  • 0.02, 0.05, 0.1, 0.2% FS accuracies
  • Gauge/Absolute/Compound/Differential
  • Unique self-protection capability
  • 5 digit resolution
  • Long working period & battery life
  • 3 times per second measure speed

TEG Images

  • The TEG range of digital pressure gauges provide high accuracy, resolution and stability. Their robust design means that each gauge can be used in critical environments where it is necessary to measure with accuracy, reproducibility, long-term stability and protection against dust.

    Gauges are available with accuracy up to 0.02% of full scale, with simple controls and various features for improved usability. An RS-232 port situated on the rear of the unit for software readback (EasyCal software from Time Electronics). Applications include lab and field pressure calibration when accompanied by a calibration pump for pressure generation. 

  • General Specifications

    Range

    Vacuum to 2500bar (see below for specific models and ranges)

    Pressure Types Gauge / Absolute / Differential / Compound

    Accuracy

    0.2% / 0.1% / 0.05% / 0.02% of full scale 

    Pressure Units

    Total of 11 pressure units possible: Pa, kPa MPa, Kgf/cm2, mmH2O, inH2O, mmHg, inHg, PSI, mbar, bar. Some units are not enabled depending on range. 

    Over Pressure Warning 120%

    Measure Speed

    Display rate: 3 readings per second (Default setting).  
    Adjustable from 10 readings per second to 1 reading every ten seconds

    Display

    LCD with backlight, pressure values displayed up to 5 digits with 16.5mm character height and analogue dial graph 25mm wide 

    Resolution

    5 digits

    Pressure Bar Graph In addition to the numeric pressure indication LCD display contains a circular fifty-one segment bar graph to provide the user with a quick visual estimation of pressure from 0 to 100% full scale output.

    Analogue Dial Graphic

    Includes pressure swing, % indication, low/high alarm

    Peak Detection

    Maximum and minimum peak values can be displayed. 

    Ambient Temperature Measurement 

    Measurement of ambient temperature, range -10°C to 50°C, resolution 0.1°C. 

    RS-232 Interface DB9. EasyCal software compatible (available from Time Electronics)
    Pressure Port ¼’’G BSP male thread, ½’’G BSP male thread (>1000bar) 0.156 inch (4mm) test hose for differential pressure (Other connections available per request)
    Environment Operating temperature: -10°C to 50°C (14°F to 122°F) / Compensation temperature: -10°C to 50°C (14°F to 122°F) / Storage Temperature: -20°C to 70°C (-4°F to 158°F) / Relative humidity: < 95%
    Power Battery: one 9V alkaline battery (included). Battery life: 300 hours (10 readings/sec), 6000 hours (1 reading/10sec), Power auto-off: 60 minutes power auto-off, can be disabled by user, 9V 5.5 x 2.1mm External power socket.
    Materials Case material: Aluminium alloy. Wetted parts: 316SS.
    Dimensions Display head only: 112mm×35mm, Total height: 178mm.
    Weight 580g


    Pressure Ranges

    Gauge Pressure
    Model # Range (bar) Range (psi) Available Accuracies (% FS)
    TEG-GVAC -1 to 0bar -15 to 0psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-G160mb 0 to 160mbar 0 to 2psi 0.05 / 0.1 / 0.2
    TEG-G350mb 0 to 350mbar 0 to 5psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-G700mb 0 to 700mbar 0 to 10psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-G1b* 0 to 1bar 0 to 15psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-G2b* 0 to 2bar 0 to 30psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-G3.5b 0 to 3.5bar 0 to 50psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-G7b 0 to 7bar 0 to 100psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-G10b 0 to 10bar 0 to 150psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-G20b 0 to 20bar 0 to 300psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-G35b 0 to 35bar 0 to 500psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-G40b 0 to 40bar 0 to 600psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-G70b 0 to 70bar 0 to 1000psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-G100b 0 to 100bar 0 to 1500psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-G140b 0 to 140bar 0 to 2000psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-G200b 0 to 200bar 0 to 3000psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-G350b 0 to 350bar 0 to 5000psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-G600b 0 to 600bar 0 to 8700psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-G700b 0 to 700bar 0 to 10000psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-G1000b 0 to 1000bar 0 to 15000psi 0.1 / 0.2
    TEG-G1600b 0 to 1600bar 0 to 25000psi 0.1 / 0.2
    TEG-G2000b 0 to 2000bar 0 to 30000psi 0.1 / 0.2
    TEG-G2500b 0 to 2500bar 0 to 36000psi 0.1 / 0.2

    Gauge Pressure Notes:
    The compensated temperature for 0.025% FS is 20°C ± 3°C. The compensated temperature for 0.05 / 0.1 /0.2% FS is 10°C to 50°C.
    Models above 70bar = Sealed Gauge Pressure
    Media: Gas only from vac to 700mbar. Gas or Liquid from 1bar to 2500bar.
    Burst Pressure: Vac to 350bar = 3x, 700 to 1000bar = 2x, 1600 to 2500bar = 1.5x. 
    * 0.025% FS for gas media only on these models. 

    Absolute Pressure
    Model # Range (bar) Range (psi) Available Accuracies (% FS)
    TEG-A350mb 0 to 350mbar 0 to 5psi 0.1 / 0.2
    TEG-A700mb 0 to 700mbar 0 to 10psi 0.1 / 0.2
    TEG-A1b 0 to 1bar 0 to 15psi 0.1 / 0.2
    TEG-A2b 0 to 2bar 0 to 30psi 0.1 / 0.2
    TEG-A3.5b 0 to 3.5bar 0 to 50psi 0.1 / 0.2
    TEG-A7b 0 to 7bar 0 to 100psi 0.05 / 0.1 / 0.2
    TEG-A10b 0 to 10bar 0 to 150psi 0.05 / 0.1 / 0.2
    TEG-A20b 0 to 20bar 0 to 300psi 0.05 / 0.1 / 0.2
    TEG-A35b 0 to 35bar 0 to 500psi 0.05 / 0.1 / 0.2
    TEG-A70b 0 to 70bar 0 to 1000psi 0.05 / 0.1 / 0.2
    TEG-A100b 0 to 100bar 0 to 1500psi 0.05 / 0.1 / 0.2
    TEG-A200b 0 to 200bar 0 to 3000psi 0.05 / 0.1 / 0.2
    TEG-A350b 0 to 350bar 0 to 5000psi 0.05 / 0.1 / 0.2

    Absolute Pressure Notes:
    Media = Gas only from 350mbar to 3.5bar. Gas or Liquid from 7bar to 350bar.
    Burst Pressure: 3x on all ranges. 

    Compound Pressure
    Model # Range (bar) Range (psi) Available Accuracies (% FS)
    TEG-C160mb 0 to ±160mbar 0 to ±2psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-C350mb 0 to ±350mbar 0 to ±5psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-C400mb 0 to ±400mbar 0 to ±6psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-C600mb 0 to ±600mbar 0 to ±9psi 0.02 / 0.05 / 0.1 / 0.2

    TEG-C1b

    0 to ±1bar

    0 to ±15psi

    0.02 / 0.05 / 0.1 / 0.2

    TEG-CV2b -1 to 2bar -15 to 30psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-CV4b -1 to 4bar -15 to 60psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-CV7b -1 to 7bar -15 to 100psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-CV10b -1 to 10bar -15 to 150psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-CV20b -1 to 20bar -15 to 300psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-CV25b -1 to 25bar -15 to 360psi 0.02 / 0.05 / 0.1 / 0.2
    TEG-CV40b -1 to 40bar -15 to 600psi 0.02 / 0.05 / 0.1 / 0.2

    Compound Pressure Notes:
    The compensated temperature for 0.02% FS is 20°C ± 3°C. The compensated temperature for 0.05 / 0.1 /0.2% FS is 10°C to 50°C.
    Media = Gas.
    Burst Pressure: 3x on all ranges. 

    Differential Pressure
    Model # Range (bar) Range (inH2O) Available Accuracies (% FS)
    TEG-DP2.5mb 0 to ±2.5mbar 0 to ±1inH2O 0.05
    TEG-DP5mb 0 to ±5mbar 0 to ±2inH2O 0.05

    TEG-DP10mb

    0 to ±10mbar

    0 to ±4inH2O

    0.05

    TEG-DP25mb 0 to ±25mbar 0 to ±10inH2O 0.05
    TEG-DP50mb 0 to ±50mbar 0 to ±20inH2O 0.05
    TEG-DP75mb 0 to ±75mbar 0 to ±30inH2O 0.05
    TEG-DP160mb 0 to ±160mbar 0 to ±50inH2O 0.05
    TEG-DP350mb 0 to ±350mbar 0 to ±150inH2O 0.02 / 0.05

    TEG-DP700mb

    0 to 700mbar

    0 to ±300inH2O

    0.02 / 0.05

    Differential Pressure Notes:
    The compensated temperature for 0.05% FS is 10°C to 50°C. The compensated temperature for 0.02% FS is 20°C ± 3°C. 
    Media = Gas.
    Burst Pressure: 2.5 & 5mb = 100x / 10mb = 50x / 25 to 75mb = 20x. 160 to 700mb = 3x. 

  • Models

    TEG Gauge

    Digital Pressure Gauge
    Model Number / Accuracy (eg. TEG-G1b/0.2) 

    Options

    C202

    Factory Calibration Certificate (NPL traceable)

    C203 UKAS Calibration Certificate (ISO 17025)
    9804 Carrying case for digital pressure gauge (up to 4 pc gauges) 
    9805 110V/220V external power adaptor (DC 9V) for digital pressure gauge
  • PDF Downloads
    File Name File Size Language

    TEG Digital Pressure Gauges Data Sheet

    400kB

    EN

  • Request for Quotation

    TEG Digital Pressure Gauges

    Product Options
    1.20

Related Products

  • 7090 Handheld Pneumatic Pressure Calibration Pump

    • Pressure to 40bar (600psi)
    • Vacuum to -950mbar
    • Oversized check valve
    • Contoured cushioned handles
    • Protective caging for vent valve
    • Hose, fittings, & carry case supplied
    • Optional digital gauges
    View 7090
  • 7095 Handheld Hydraulic Pressure Calibration Pump

    • 0 to 700bar (10,000psi) 
    • Priming feature for fast air purge 
    • Oversized check valve
    • Contoured cushioned handles
    • Built-in pressure relief valve  
    • Hose, fittings, & carry case supplied
    • Optional digital gauge
    View 7095