Pressure Calibrators, Digital Gauges and Calibration Pumps
Time Electronics have a range of instruments for pressure calibration, generation and measurement. Products include portable pressure calibrators for use in the field, and pressure controllers for calibration labs and instrumentation workshops. For pressure generation the range of pneumatic pumps is for use up to 200bar, and hydraulic pumps for up to 700bar (2500bar available upon request). Products are designed to complement each other, with digital pressure gauges and pressure calibrators suitable for use with accompanying pressure pumps. Both lab and field pressure calibration work can be performed for instrumentation such as transmitters, switches, gauges and sensors.
-
7010 Single Channel Pressure Calibrator
- Vacuum to 600bar versions
- Accuracy 0.04% of full scale
- Pneumatic or hydraulic
- Over-pressure alarm
- Isolated 24/36V loop supply
- Loop current measure
- Mains / battery power
-
7015 Dual Channel Pressure Calibrator
- Vacuum to 600bar versions
- Accuracy 0.04% of full scale
- Pneumatic or hydraulic
- Over- pressure alarm
- Isolated 24/36V loop supply
- Loop current measure
- Mains / battery power
-
7016 Regulated Low Pressure Calibrator
- Regulated low pressure
- Vacuum to 10bar versions
- Accuracy 0.04% of full scale
- Pneumatic
- Isolated 24/36V loop supply
- Loop current measure
- Mains / battery power
-
7018 Differential Pressure Calibrator
- 0.2, 2, 5 & 10bar versions
- Accuracy 0.04% of full scale
- Pneumatic
- Over-pressure alarm
- Isolated 24/36V loop supply
- Loop current measure
- Mains or battery powered
-
7040 Digital Pressure/Current Calibrator
- Vacuum to 20bar versions
- 0.04% accuracy
- Loop current calibration
- 9 engineering units
- Min / Max function
- Leak rate function
- RS-232 serial interface
-
7078 Auto-Ranging Digital Pressure Gauge
- Vacuum to 200bar (3000psi)
- Accuracy 0.1% of reading
- 9 engineering units
- Silicone piezo resistive sensors
- Reads gauge & absolute pressure
- Easy to read backlit display
- Robust with protective rubber boot
-
7090 Handheld Pneumatic Pressure Calibration Pump
- Pressure to 40bar (600psi)
- Vacuum to -950mbar
- Oversized check valve
- Contoured cushioned handles
- Protective caging for vent valve
- Hose, fittings, & carry case supplied
- Optional digital gauges
-
7091 Digital Pressure Gauge
- Vacuum to 40bar (600psi)
- Accuracy 0.2% of full scale
- Easy-to-read display
- 5 digit resolution
- 3 times per second measure speed
- Analogue dial indicates % pressure
- Ideal for use with the 7090 pump
-
7093 Precision Loop and Dual Pressure Calibrator
- Vacuum to 600bar versions
- Pressure accuracy 0.04% of FS
- 0.025% high accuracy versions
- Pneumatic or hydraulic
- I measure: 125mA, Source: 50mA
- V measure: 25V, Source: 21V
- V/I accuracy 0.01%
-
7094 Digital Pressure Gauge
- 0 to 100bar (1500psi) pressure
- Accuracy 0.2% of full scale
- Easy-to-read display
- 5 digit resolution
- 3 times per second measure speed
- Analogue dial indicates % pressure
- Ideal for use with the 7194 pump
-
7095 Handheld Hydraulic Pressure Calibration Pump
- 0 to 700bar (10,000psi)
- Priming feature for fast air purge
- Oversized check valve
- Contoured cushioned handles
- Built-in pressure relief valve
- Hose, fittings, & carry case supplied
- Optional digital gauge
-
7096 Digital Pressure Gauge
- Pressure up to 700bar
- Accuracy 0.2% of full scale
- Up to 5000 hours battery life
- Easy-to-read display
- 5 digit resolution
- 3 times per second measure speed
- Ideal for use with the 7095 pump
-
7190 Benchtop Micro-Pressure Calibration Pump
- -0.4bar vacuum to 0.4bar (6psi)
- Double output manifold
- Resolution: 0.0001mbar (0.01Pa)
- Screw press for fine adjustment
- Bellows minimise leakage
- Isothermal chamber for stability
- Compact, lightweight design
-
7191 Benchtop Low Pressure Calibration Pump
- -0.95bar vacuum to 4bar (60psi)
- Double output manifold
- Resolution: 0.0001mbar (0.01Pa)
- Screw press for fine adjustment
- Bellows minimise leakage
- Isothermal chamber for stability
- Compact, lightweight design
-
7193 Benchtop Pneumatic Pressure Calibration Pump
- 0.95bar vacuum to 40bar (600psi)
- Pneumatic
- Double output manifold
- Ideal for use as gauge comparator
- High pressure resolution (0.1mbar)
- Screw press for fine adjustment
- Compact design ideal for field or lab
-
7194 Benchtop Pneumatic Pressure Calibration Pump
- 0.95bar vacuum to 140bar (2000psi)
- Double output manifold
- High pressure resolution
- High pressure stability
- Easy to use pressure lever/handle
- Free from humidity and dirt
- For reference calibration with gauge
-
7195 Benchtop Hydraulic Pressure Calibration Pump
- Vacuum to 700bar (10,000psi)
- Double output manifold
- High pressure resolution
- High pressure stability
- Smooth pressure generation
- Oil or deionized water
- For reference calibration with gauge
-
7198 Pressure Calibration Accessories Kit
- Adaptors/fittings/connectors/hoses
- Metric/BSP/parallel/NPT adaptors
- Coupling connectors
- Quick release & minimess hoses
- 10" adjustable spanner included
- Suitable for use with pumps
- Compact kit for labs & on-site work
-
TEG Digital Pressure Gauges
- Ranges to 2500bar (37500psi)
- 0.02, 0.05, 0.1, 0.2% FS accuracies
- Gauge/Absolute/Compound/Differential
- Unique self-protection capability
- 5 digit resolution
- Long working period & battery life
- 3 times per second measure speed