Features

  • -200°C to + 800°C
  • ± 0.3°C accuracy
  • Based on ITS 90 EN60751
  • 23 set points
  • Exceeds class A
  • Good temperature stability
  • Passive resistance source

1049 Images

  • The 1049 is a handheld precision simulator for PT100 0.3850 platinum resistance elements used for accurate temperature measurement. 

    It follows the PT100 scale from -200°C to +800°C with 23 set points. High performance metal film resistors are used throughout which ensures a good temperature coefficient and long term stability.

    The specification is in accordance with DIN EN 60751 (ITS 90). Offering high accuracy across the full operating range of PT100 devices it exceeds the performance of Class A & B. The 1049 will be of particular interest to those operating in the -60 to +60°C range where a performance exceeding Class A (e.g. better than +/- 0.15°C at 0°C), is required.

    Since the 1049’s output is a purely passive resistance it will operate with all types of PT100 measuring equipment including the live systems using pulsed, or interrupted excitation current. The pocket sized design (112 x 61 x 55mm) makes it easily portable and ideal for lab or field use. The instrument is supplied as standard with a carry case.

    This 1049 is part of the Time Electronics portable testing equipment line. As a PT100 simulator for temperature measurement equipment it offers high stability and ease of use across applications.

  • Technical Specifications

    Set Points °C -200, -100, -50, -20, -10, 0, 10, 20, 30, 40, 50, 60, 80, 100, 150, 200, 250, 300, 400, 500, 600, 700, 800.
    Range -200 to -100°C -50 to +60°C +80 to +200°C +250 to +500°C +600 to +800°C
    Accuracy ± 0.3°C ± 0.15°C ± 0.3°C ± 0.5°C ± 0.65°C
    Temperature Coefficient Less than 30ppm/°C
    Maximum Current 50mA


    General Specifications

    Dimensions H112 x W61 x D55mm
    Weight 0.17kg
    Supplied With Carry case and user manual
    Optional Extras Calibration certificates traceable NPL and UKAS
    Country of Origin UK
  • Models
    1049 PT100 Simulator (°C)

    1050

    PT100 Simulator (°F) - View web page

    Options

    C161

    Factory Calibration Certificate (NPL traceable)

    C114 UKAS Calibration Certificate (ISO 17025)
  • PDF Downloads
    File Name File Size Language

    1049 Data Sheet

    178kB

    EN

    1049 User Manual

    277kB

    EN / FR / DE / IT

  • Request for Quotation

    1049 PT100 Simulator

    Product Options
    1.20

Related Products

  • 1050 PT100 Simulator

    • -100°F to + 1000°F
    • ± 0.5°F accuracy
    • Based on ITS 90 EN60751
    • 23 set points
    • Exceeds class A
    • Good temperature stability
    • Passive resistance source
    View 1050
  • 1051 Resistance Decade Box

    • 0.01 Ω to 1 MΩ
    • High accuracy and stability
    • Clear visual indication
    • Safety terminals
    • Low temperature coefficient
    • Suitable for PRT/RTD
    • Supplied with protective cover
    View 1051
  • 1067 Precision Resistance Decade Box

    • 10mΩ to 12kΩ
    • 0.01% accuracy
    • Precision PT100 simulation
    • 6 digit resolution
    • Better than 20ppm/year stability
    • Residual resistance < 10mΩ
    • Fully screened
    View 1067
  • 7000 RTD Temperature Calibrator

    • 0.05°C accuracy, 0.01°C resolution
    • 0.03Ω accuracy, 0.01Ω resolution
    • 2, 3 and 4 wire connections
    • Read and simulate °C, °F, °K, Ω
    • Ramp and step
    • PT100 plus 7 other RTD types
    • User programmable
    View 7000