Products commonly used in this industry
-
5075 7.5 digit Multimeter
- 7.5 digit resolution
- AC/DC voltage and current
- Resistance and temperature
- Capacitance
- Frequency
- 18 ppm best accuracy
- 10 channel scanner option
-
5025E Multifunction Calibrator
- 40 ppm precision calibrator
- 0 to 1050 V AC/DC voltage
- 0 to 22 A AC/DC current
- Resistance and capacitance
- Thermocouple and Pt100 simulation
- Clamp meter and power calibration
- Optional oscilloscope calibration
-
5025C Multifunction Calibrator
- 15 ppm precision calibrator
- 0 to 1050 V AC/DC voltage
- 0 to 22 A AC/DC current
- 1 Ω to 1.1 GΩ variable resistance
- Thermocouple and Pt100 simulation
- Clamp meter and power calibration
- Capacitance and inductance
-
1044 Voltage and Current Calibrator
- Measure voltage and current
- Source voltage and current
- 3 voltage ranges 0 to 20 V
- 3 current ranges 0 to 20 mA
- Accuracy 0.05 %
- 3.5 digit LCD display
- Portable with 28 hours typical battery life
-
1051 Resistance Decade Box
- 0.01 Ω to 1 MΩ
- High accuracy and stability
- Simple operation with clear visual indication
- Suitable for Pt100 simulation
- Low temperature coefficient
- Safety terminals
- Removable protective cover
-
1040 Resistance Decade Box
- 1 Ω to 100 MΩ
- High accuracy
- Clear visual indication
- High stability
- Safety terminals
- Low temperature coefficient
- Supplied with protective cover
-
1067 Precision Resistance Decade Box
- 10 mΩ to 12 kΩ
- 0.01 % accuracy
- Precision Pt100 simulation
- 6 digit resolution
- Better than 20 ppm/year stability
- Residual resistance < 10 mΩ
- Fully screened
-
5018 Programmable DC/AC V/I Calibrator
- 0 to 22 V DC
- 220 V and 1 kV DC options
- 0 to 220 mA AC/DC options
- 0 to 22 V AC option
- Ramping feature
- GPIB / RS-232 / USB interfaces
- Ideal for ATE applications
-
5065 6.5 digit Multimeter
- DC V to 1000 V, AC V to 750 V
- AC/DC current to 3 A
- Two and four wire resistance
- Frequency from 3 Hz to 300 kHz
- Period and diode measurement
- Temperature measurements
- USB interface, optional GPIB
-
5069 Insulation Tester Calibrator
- 100 kΩ to 100 GΩ
- Basic accuracy 1 %
- Up to 10 kV operation
- Portable with battery operation
- Fully shrouded safety connectors
- Display of open circuit voltage
- Display of short circuit current
-
5070 Micro-Ohmmeter Calibrator
- Calibrate ductor testers
- Calibrate micro-ohmmeters
- 0.2, 2, 20, 200, 2000 mΩ
- 5 cal points: 0/25/50/75/100 %
- Gold plated terminals
- Low thermal EMF connection
- Portable robust carrying case
-
5077 Multifunction Power Calibrator
- 0 to 1050 V AC/DC voltage
- 0 to 22 A AC/DC current
- Single-phase power simulation
- Up to 23 kVA or 23 kW
- Phase angle ± 90.0°
- Power factor 0.00 to 1.00
- 40 to 500 Hz adjustable frequency
-
CalBench Calibration Benches
View CalBench- Universal calibration systems
- Electrical/pressure/process
- Power supplies, DMMs & scopes
- Multifunction calibrator modules
- Ideal for on-site test facilities
- Automatic or manual calibration
- Complete lab design service
-
7090 Pneumatic Calibration Pump
- Pressure to 40 bar (600 psi)
- Vacuum to -950 mbar
- Oversized check valve
- Contoured cushioned handles
- Protective caging for vent valve
- Hose, fittings, & carry case supplied
- Optional digital gauges
-
7095 Hydraulic Calibration Pump
- 0 to 700 bar (10,000 psi)
- Priming feature for fast air purge
- Oversized check valve
- Contoured cushioned handles
- Built-in pressure relief valve
- Hose, fittings, & carry case supplied
- Optional digital gauges