1067 Precision Resistance Decade Box

1067 Precision Resistance Substitution Box
  • 1067 Precision Resistance Decade Box

Features

  • 10mΩ to 12kΩ
  • 0.01% accuracy
  • Precision PT100 simulation
  • 6 digit resolution
  • Better than 20ppm/year stability
  • Residual resistance < 10mΩ
  • Fully screened

1067 Images

  • A precision resistance decade box suitable for a wide range of simulation work. High accuracy, long term stability, and low temperature coefficient make the 1067 ideal for simulating and calibrating precision PT100 sensors and temperature indicators/meters that use resistive sensors.

    Special care has been taken in the construction of this precision decade box to ensure that the residual end resistance is as low and as stable as possible. Multiple self-cleaning silver alloy contacts are used for each position to ensure outstanding performance and long life. 

    Housed in a robust metal case the 1067 is fully screened and low thermal emf terminals are used. The slim line design means it takes up minimum bench space and is easily transportable.

    Resistance is selected by dialling the value required using the rotary switches. This enables precise setting with a clear unambiguous indication.
    Each decade is scaled from 0 to 11 and therefore allows convenient overlap of the set values. The maximum value settable is 12,222.21 ohms.

  • Technical Specifications

    Range

    0 to 12kΩ

    Resolution

    10mΩ steps

    Number of Decades

    6, each decade settable from 0 to 11

    Accuracy

    ± 0.01% of setting ± 2mΩ, after deduction of residual end resistance ±1mΩ for residual variation. At calibration temperature of 22°C.

    Residual Resistance

    Less than 10mΩ. Less than 1mΩ variation

    Power Rating

    0.35 watt per resistor

    Voltage Rating

    Maximum 200V DC/AC RMS

    Stability

    20ppm/year (>1Ω), 100ppm/year (<1Ω)

    Current Rating

    10mΩ range: 3A, 100mΩ range: 2A, 1Ω range: 600mA, 10Ω range: 200mA, 100Ω range: 60mA, 1kΩ range: 20mA

    Insulation

    Case to resistance terminals 2kV / 50Hz maximum

    Temperature Coefficient

    Less than 10ppm/°C (> 1Ω). Less than 20ppm/°C (< 1Ω)

    Operating Torque

    Less than 0.1Nm

    Contacts

    Make before break – silver alloy


    General Specifications

    Dimensions

    W355 x H63 x D89mm

    Weight

    1.1kg

    Optional Extras

    Calibration certificates traceable to NPL and UKAS

    Country of Origin UK
  • Models

    1067

    Precision Resistance Decade Box

    Options

    C161

    Factory Calibration Certificate (NPL traceable)

    C114 UKAS Calibration Certificate (ISO 17025)
  • PDF Downloads
    File Name File Size Language

    1067 Data Sheet

    211kB

    EN

    1067 User Manual

    177kB

    EN

  • Request for Quotation

    1067 Precision Resistance Decade Box

    Product Options
    1.20

Related Products

  • 1040 Resistance Decade Box

    • 1 Ω to 100 MΩ
    • High accuracy
    • Clear visual indication
    • High stability
    • Safety terminals
    • Low temperature coefficient
    • Supplied with protective cover
    View 1040
  • 1041 Decade Resistance Box

    • 0.01 Ω to 1 kΩ
    • 10 mΩ resolution
    • Ideal for PRT and RTD
    • High stability
    • Safety terminals
    • Low temperature coefficient
    • Supplied with protective cover
    View 1041
  • 1051 Resistance Decade Box

    • 0.01 Ω to 1 MΩ
    • High accuracy and stability
    • Clear visual indication
    • Safety terminals
    • Low temperature coefficient
    • Suitable for PRT/RTD
    • Supplied with protective cover
    View 1051
  • 1061 Resistance Decade Box

    • 1Ω to 1.2MΩ
    • In-line readout
    • Stable metal film resistors
    • Mechanically/electrically robust
    • Ideal for education & electronics
    • Safety terminals
    • Fully screened
    View 1061