5077 Power Calibrator

5077 Power Calibrator
  • 5077 Power calibrator
  • 5077 Power calibrator with virtual control software

Features

  • Single-phase power simulation
  • Simultaneous supply of V and I
  • Up to 1050 V AC/DC
  • Up to 22 A AC/DC
  • Up to 22 kVA or 22 kW
  • Phase angle ± 90°, PF 0.00 to 1.00
  • 40 to 400 Hz in 0.01 Hz steps

5077 Images

  • A high accuracy AC and DC power calibrator suitable for calibrating single-phase watt-meters, power meters, and kW-Hr meters. The 5077 is a practical solution to precision power simulation, providing a simultaneous supply of voltage and current with phase control. The unit is operated via a virtual control software application allowing the user full control via laptop or PC.

    The 5077 voltage range is 20 mV to 1050 V, with current from 20 mA to 22 A. Frequency can be set in 0.01 Hz steps from 40 to 400 Hz, and phase in 0.1° steps. Alternatively power factor (PF) can be set in steps of 0.01. The output can be displayed as VA or Watts. The wide current and voltage ranges enable verification of power meters on either the primary side of the of the CT / VT or directly connected to the meter (secondary side).

    The standard maximum AC current output (22 A) can be extended to 100 A by using an optional 100 A current transformer. This extends the maximum power to 0.1 MW/MVA. A single and 50-turn current clamp adaptor is available for clamp sensor and meter calibration up to 1100 A.

    PC/Laptop Virtual Control Panel
    A simple user interface application that enables the operator to control the 5077. Select functions, set and output values as required.

    EasyCal Calibration Software
    The 5077 can be controlled via Time Electronics EasyCal software to automate the calibration process. This provides increased speed of calibration and consistency of results. Produce traceable calibration certificates and test reports for quality standards with additional uncertainty information for ISO 17025 conformance.
     

  • Technical Specifications

    Specifications apply to 5077 models that feature both low and high current terminals (year 2020 onwards).
    Accuracy specifications are shown as ±(% of output + floor). Specifications apply at 23 °C ± 5 °C. All values are relative to calibration standards.

    DC Voltage
    Range Accuracy 1 year Output Resistance Max Output Current Resolution
    20 to 2 mV 0.01 % + 125 μV 10 Ω - 1 μV
    0.02 to 2 V 0.01 % + 250 μV < 0.5 Ω 20 mA 1 μV
    2 to 20 V 0.01 % + 500 μV < 0.5 Ω 20 mA 10 μV
    20 to 200 V 0.02 % + 30 mV < 5 Ω 20 mA 100 μV

    200 to 1050 V

    0.05 % + 50 mV

    < 10 Ω

    10 mA

    1 mV

    DC Current
    Range Accuracy 1 year Compliance Voltage Resolution
    2 to 20 mA 0.015 % + 10 μA 10 V 1 μA
    20 to 200 mA 0.15 % + 100 μA 10 V 10 μA
    0.2 to 2 A 0.03 % + 500 μA 5 V 100 μA
    2 to 22 A 0.05 % + 6 mA 4 V 1 mA
    AC Voltage (40.00 Hz to 400.00 Hz, 0.02 % accuracy)
    Range Accuracy 1 year Output Resistance Max Output Current Resolution
    20 to 200 mV 0.03  % + 250 μV 10 Ω - 100 μV
    0.2 to 2 V 0.03 % + 500 μV < 0.5 Ω 20 mA 100 μV
    2 to 20 V 0.03 % + 2 mV < 1 Ω 20 mA 1 mV
    20 to 200 V 0.06 % + 30 mV < 5 Ω 20 mA 10 mV
    200 to 300 V 0.06 % + 30 mV < 5 Ω 10 mA 10 mV

    300 to 1050 V

    0.08 % + 90 mV

    < 10 Ω

    10 mA

    100 mV

    AC Current (40.00 Hz to 400.00 Hz 0.02 % Accuracy)
    Range Accuracy 1 year Compliance Voltage Resolution
    2 to 20 mA 0.1 % + 20 μA 10 V 1 μA
    20 to 200 mA 0.1 % + 200 μA 10 V 10 μA
    0.2 to 2 A 0.1 % + 2 mA 3.5 V 100 μA
    2 to 22 A 0.1 % + 20 mA 3 V 1 mA
    Phase Angle
    Frequency Range Accuracy 1 year Resolution
    40 to 99.99 Hz –90.0 to 90.0° ± 0.3° 0.1°
    100 Hz to 400 Hz –90.0 to 90.0° ± 1° 0.1°
    Power Factor
    Frequency Range Resolution
    40 to 400 Hz 0.00 to 1.00 0.01

    The accuracy of the power is complex and is determined by using a formula, which combines the errors due to Voltage, Current, and Phase.
    Power Accuracy (%) = SqrRt (Voltage accuracy² + Current accuracy² + Phase Correction²).
    Where Phase Correction (%) = 100x(1-Cos(Phase+PhaseAcc)/Cos Phase).


    General Specifications

    Warm up 1 hour to full accuracy
    Settling Time Less than 5 seconds

    Standard Interfaces

    GPIB (IEEE-488), RS-232, USB

    Temp Performance Operating: 0 to 40 °C, Full Spec: 23 °C ± 5 °C, Storage: –10 °C to 50 °C
    Operating Humidity < 80 % non-condensing
    Operating Altitude 0 to 3 km. Non operating: 3 km to 12 km
    Line Power 100 to 230 V AC 50/60 Hz. Power Consumption 60 W typical, 80 W Max.

    Dimensions

    W 440 x H 198 x D 480 mm (17.6 x 7.8 x 32.8 ”)

    Weight 25 kg (36 lbs)
    Country of Origin UK

    Supplied With

    Virtual control software, user manual, RS-232 cable, and USB adaptor/cable

  • Models

    5077

    Power Calibrator

    Options

    9790

    100 Amp AC current transformer  -  View data sheet

    9780

    Clamp meter adaptor (Single/50 turn coil)  -  View data sheet

    9735 Test lead set
    C160 Traceable calibration certificate (Factory)
    C124 Accredited calibration certificate (ISO 17025)
    Calibration Software and Accessories

    ECFLA

    EasyCal Full License - when purchased with multifunction calibrator/DMM: Discounted full license with 1 year support.
    For further licenses and EasyCal add-ons see the Easycal web page or PDF brochure

    9795 Printer & connectivity kit (printer, 4 port USB hub, numeric key pad & USB memory stick)
    9777 Bar code reader
    9778 Cal and ID label printer
    9779 Job and address label printer
    9597 GPIB cable
    9743 PCI to GPIB interface card

    9794

    GPIB to USB adaptor

    ESP1

    EasyCal support package 1: 1 year email and telephone support. Minor upgrades. 

    ESP2 EasyCal support package 2: 2 year email and telephone support. Minor upgrades.
    EOT1 EasyCal online training session (Via remote desktop)
  • PDF Downloads
    File Name File Size Language

    5077 Data Sheet

    600 kB

    EN

    9790 AC Current Transformer Data Sheet

    235 kB

    EN

    9780 Clamp Meter Adaptor Data Sheet

    284 kB

    EN

    EasyCal Brochure

    4 MB (low resolution)

    EN

    EasyCal Brochure

    8 MB (Higher resolution)

    EN

  • Request for Quotation

    5077 Power Calibrator

    Product Options
    1.20

Related Products

  • 5018 Programmable DC/AC V/I Calibrator

    • 0 - 22V DCV (30V DC optional)
    • 0 - 22V AC, 220V & 1kV DC options
    • Optional 0 - 220mA AC/DC
    • Ramping feature
    • GPIB / RS-232 / USB interfaces
    • Ideal for ATE applications
    • EasyCal Software compatible
    View 5018
  • 5025C Multifunction Calibrator

    • 15ppm precision calibrator
    • Calibrate up to 6.5 digit meters
    • 11 standard functions 
    • 0 - 1050V & 0 - 22A (AC/DC)
    • Resistance & capacitance
    • Thermocouple/PT100 simulation
    • Oscilloscope & power options
    View 5025C
  • 5051+ Multifunction Calibration System

    • Combined calibrator/DMM/PC
    • 0 - 1050 V & 0 - 22 A (AC/DC)
    • Source up to 1 GΩ resistance
    • Thermocouple simulate/measure
    • PT100, C & L, scope calibration
    • Clamp meter calibration
    • EasyCal Software included
    View 5051+