
The CBP-PRES1 CalBench is a package that provides users with the capabilities to perform rapid calibration of pressure instrumentation. It is an ideal solution for instrument workshops that require a high performance workstation as the platform for calibration of plant devices and instruments.
The CalBench features 8030B auto-pneumatic controller modules for calibration work to 200 bar (3000 psi). The low range controller covers pressure to 20 bar (300 psi) with a vacuum to 2 bar (30 psi) sub-range. The line pressure and vacuum to this module is via electric pumps, meaning no requirement for external supply. The high pressure controller has 2 ranges to 200 bar (3000 psi). Line pressure to this module is typically via a pressure cylinder, we supply a regulator kit for fitting and use. Both controllers have barometric reference sensors that enables switching from gauge to absolute pressure.
Additional pressure modules include differential and gauge measurement modules for pneumatic and hydraulic testing applications. They can be used with the supplied benchtop pumps. Manifolds, test stand, adaptors and fittings are also provided.
The 8060+ module situates centrally in the console, providing source, simulation and measurement of process signals, HART communication and 24 V loop power. It features an integral multimeter, and a PC control centre with 12.1” touch screen display. Pressure control and readback applications are included. EasyCal software communicates with pressure modules, and can be used for automated calibration and test management.
Features
- Advanced pressure calibration bench
- Auto-pneumatic pressure controller modules
- Pneumatic, hydraulic & DP measure modules
- Process calibrator/multimeter/PC module
- Source/measure V, I , Ω, Hz, temperature
- Line pressure & vacuum pumps included
- Fixed & variable DC power supply modules
- Regulator kit for cylinder fitting supplied
- Pumps, manifolds, fittings, UUT stand
- Environmental monitor/datalogger included
- Automated calibration using EasyCal software
- Customisable pressure ranges (pre-order)

Pressure Calibration
The two automatic controller modules are used for pneumatic calibration from vacuum to 200 bar (3000 psi). Additionally, precision measurement modules provide low range differential to high range hydraulic coverage. Calibrate instrumentation such as:
- Analogue and digital gauges, indicators, manometers
- Calibrators, sensors, transducers, transmitters
- Switches, valves, controllers, chart recorders

Line Pressure Solutions
The package includes two electric pumps and a regulator kit for use with a pressure cylinder. The pumps make the low range 8030B self-sufficient from vacuum to 20 bar, meaning quick setup and easy maintenance.
- 7165 electric pump: 24 bar (350 psi) to low range 8030B module
- 7149 electric vacuum pump: Vacuum to low range 8030B module
- XREG regulator kit: Used on a cylinder to high range 8030B module
- Manual operation pneumatic & hydraulic pumps also included

Additional Applications
The CBP-PRES1 is a primarily a pressure calibration system, but can also be used to check and verify functions on process instruments. It is also ideal for training to show a wide range of test and measurement applications.
- Test process calibrators, mV/mA meters, decade boxes, flow totalizers
- Add dry block calibrators for temperature calibration capabilities
- Train engineers & technicians instrumentation calibration
- Run a complete calibration program with EasyCal software
EasyCal Calibration Software
The CBP-PRES1 comes with EasyCal software on the 8060 control centre. This enables software driven testing procedures and provides increased speed of calibration and consistency of results.
Produce traceable calibration certificates and test reports for quality standards with additional uncertainty information for ISO 17025 conformance.

Details
Downloads
File Name | File Size | Language | Format |
---|---|---|---|
615 kB |
EN |
|
11.5 MB |
EN |
|
Request a quote
CBP-PRES1 CalBench Package
- Product Ranges
- Decade Boxes
- Portable Voltage & Current Calibrators
- Electrical Multifunction Calibrators
- ATE / Bench Calibrators & Multimeters
- Electrical Test Equipment Calibrators
- Process Calibration Instruments
- Pressure Calibration Instruments
- Calibration Benches
- Calibration Software
- Accessories
- Discontinued Products
- Products by Function
- Calibration Benches
- Industries
- Services
- Resources
- About
- Contact