Products commonly used in this industry

  • Education

    1044 Voltage and Current Calibrator

    • Measure voltage and current
    • Source voltage and current
    • 3 voltage ranges 0 to 20 V
    • 3 current ranges 0 to 20 mA
    • Accuracy 0.05 %
    • 4.5 digit LCD display
    • Portable with 28 hours typical battery life
    View 1044
  • Education

    1051 Resistance Decade Box

    • 0.01 Ω to 1 MΩ
    • High accuracy and stability
    • Simple operation with clear visual indication
    • Suitable for Pt100 simulation
    • Low temperature coefficient
    • Safety terminals
    • Removable protective cover
    View 1051
  • Education

    1040 Resistance Decade Box

    • 1 Ω to 100 MΩ
    • High accuracy
    • Clear visual indication
    • High stability
    • Safety terminals
    • Low temperature coefficient
    • Supplied with protective cover
    View 1040
  • Education

    1041 Resistance Decade Box

    • 0.01 Ω to 1 kΩ
    • 10 mΩ resolution
    • Ideal for PRT and RTD
    • High stability
    • Safety terminals
    • Low temperature coefficient
    • Supplied with protective cover
    View 1041
  • Education

    1049 Pt100 Simulator

    • –200 °C to +800 °C
    • ± 0.3 °C accuracy
    • Based on ITS 90 EN 60751
    • 23 set points
    • Exceeds class A
    • Good temperature stability
    • Passive resistance source
    View 1049
  • Education

    1053 Inductance Decade Box

    • 1 mH to 10 H
    • In-line readout
    • 3 % accuracy
    • High stability
    • Safety terminals
    • Fully screened
    • Robust and portable
    View 1053
  • Education

    1061 Resistance Decade Box

    • 1 Ω to 1.2 MΩ
    • In-line readout
    • Stable metal film resistors
    • Mechanically and electrically robust
    • Ideal for education and electronics
    • Safety terminals
    • Fully screened
    View 1061
  • Education

    1071 Capacitance Decade Box

    • 10 pF to 100 μF
    • 1 % accuracy
    • In-line readout
    • Colour coded digits
    • Safety terminals
    • Bi-polar working
    • Supplied with protective cover
    View 1071
  • Education

    5018 Programmable DC/AC V/I Calibrator

    • 0 to 22 V DC
    • 220 V and 1 kV DC options
    • 0 to 220 mA AC/DC options
    • 0 to 22 V AC option
    • Ramping feature
    • GPIB / RS-232 / USB interfaces
    • Ideal for ATE applications
    View 5018
  • Education

    5065 6.5 digit Multimeter

    • DC V to 1000 V, AC V to 750 V
    • AC/DC current to 3 A
    • Two and four wire resistance
    • Frequency from 3 Hz to 300 kHz
    • Period and diode measurement
    • Temperature measurements
    • USB interface, optional GPIB
    View 5065
  • Education

    CalBench Calibration Benches

    • Universal calibration systems
    • Electrical/pressure/process
    • Power supplies, DMMs & scopes
    • Multifunction calibrator modules
    • Ideal for on-site test facilities
    • Automatic or manual calibration
    • Complete lab design service
    View CalBench
  • Education

    7006 Loop Simulator & Source

    • 4 to 20 mA or 0 to 10 V loops
    • 7 calibration set-points
    • Accuracy 0.1 %
    • TxSim and RxTest modes
    • Autostep output - adjustable rate
    • Battery powered PP3
    • Internal loop drive supply
    View 7006
  • Education

    7040 Digital Pressure/Current Calibrator

    • Vacuum to 20 bar versions
    • 0.04 % accuracy
    • Loop current calibration
    • 9 engineering units
    • Min / Max function
    • Leak rate function
    • RS-232 serial interface
    View 7040
  • Education

    7090 Pneumatic Calibration Pump

    • Pressure to 40 bar (600 psi)
    • Vacuum to -950 mbar
    • Oversized check valve
    • Contoured cushioned handles
    • Protective caging for vent valve
    • Hose, fittings, & carry case supplied
    • Optional digital gauges
    View 7090
  • Education

    8100 Instrumentation Test Stand

    • Multi-purpose test stand
    • For process & pressure instrumentation
    • Configurable solution for workshop use
    • 2 transmitter poles for U-bolt connections
    • Pressure manifold with quick connect port
    • Quick-vice with sliding jaw
    • Retort rod for RTDs and thermocouples
    View 8100