  • 0.01 Ω to 1 kΩ
  • 10 mΩ resolution
  • Ideal for PRT and RTD
  • High stability
  • Safety terminals
  • Low temperature coefficient
  • Supplied with protective cover

1041 Images

  • A precision low ohm resistance box designed for general laboratory work including platinum resistance thermometry.

    The 1041 decade box is compact and durable, housed in a robust metal case with removable protective rubber cover, making it ideal for use in either the laboratory or field. Excellent accuracy is achieved by using high stability metal film resistors. The 5 digit thumbwheel switch enables simple and precise setting with a clear indication of the resistance value.

    Switch Contacts
    Special attention has been given to the reliability of operation. A special multiple gold contact arrangement ensures low contact resistance and continued operation even if a contact fails.

    Clear Visual Indication
    To make selecting and reading the setting easy the 1041 incorporates colour coded digits: ohms - white, milliohms - yellow.

    Safety Terminals
    Compatible with 4 mm shrouded plugs, as well as standard plugs, bare wires, and spade terminals.

    Added Protection
    The 1041 comes fitted with an ergonomic rubber cover providing increased protection and durability. It has a textured grip for comfortable handling and side openings to place labels. It is easy to remove if the user prefers a stand-alone unit or to house the 1041 in the optional 9026 carry case.

    This low ohm resistance box is part of the Time Electronics well-proven decade box line. It can be used as a calibration standard for site and workshop use and is ideal for PT100 and other resistance input instrumentation. 

  • Technical Specifications

    Range

    0 to 1 kΩ

    Resolution 0.01 Ω steps
    Decade 0.01 Ω 0.1 Ω 1 Ω 10 Ω 100 Ω
    Accuracy ± 10 % ± 5% ± 1 % ± 0.5 % ± 0.1 %
    Max Current 1A 1A 1A 0.3A 0.1A
    Residual Resistance Less than 60 mΩ
    Power Rating 1 W per resistor
    Voltage Rating Maximum 100 V DC/AC RMS
    Temperature Coefficient 50 ppm/°C


    General Specifications

    Dimensions W 215 x H 100 x D 120 mm including protective cover (W 200 x H 75 x D 110 mm without)
    Weight 1kg including protective cover (0.6 kg without)
    Supplied With Protective cover (fitted) and user manual
    Optional Extras Leather carry case. Calibration certificates: Traceable (factory) and accredited (ISO 17025).
    Country of Origin UK
  • Models

    1041

    Low Ohm Resistance Decade Box

    Options
    9026 Leatherette Carry Case
    C161 Traceable calibration certificate (Factory)
    C114 Accredited calibration certificate (ISO 17025)
  • PDF Downloads
    File Name Language

    1041 Data Sheet

    EN

    1041 User Manual

    EN

    Carry Case Option Data Sheet EN
  • Request for Quotation

    1041 Decade Resistance Box

    Product Options
    1.20

Related Products

  • 1040 Resistance Decade Box

    • 1 Ω to 100 MΩ
    • High accuracy
    • Clear visual indication
    • High stability
    • Safety terminals
    • Low temperature coefficient
    • Supplied with protective cover
    View 1040
  • 1051 Resistance Decade Box

    • 0.01 Ω to 1 MΩ
    • High accuracy and stability
    • Clear visual indication
    • Safety terminals
    • Low temperature coefficient
    • Suitable for PRT/RTD
    • Supplied with protective cover
    View 1051
  • 1061 Resistance Decade Box

    • 1Ω to 1.2MΩ
    • In-line readout
    • Stable metal film resistors
    • Mechanically/electrically robust
    • Ideal for education & electronics
    • Safety terminals
    • Fully screened
    View 1061
  • 1067 Precision Resistance Decade Box

    • 10mΩ to 12kΩ
    • 0.01% accuracy
    • Precision PT100 simulation
    • 6 digit resolution
    • Better than 20ppm/year stability
    • Residual resistance < 10mΩ
    • Fully screened