The CBP-PROC1 CalBench is a package that provides users with the capabilities to perform rapid calibration of process, temperature and pressure instrumentation. It is an ideal solution for instrument workshops that require a high performance workstation as the platform for calibration of plant devices and instruments.
The system features the 8060+ module situated centrally in the console for calibration and communication. It provides source, simulation and measurement of process signals, HART communication and 24 V loop power. It also includes an integral 6.5 digit multimeter, and a PC control centre with 12.1" touch screen display. The control centre has manual control applications and EasyCal software for automated calibration and test management. EasyCal communicates with pressure modules and dry block calibrators.
The modules and accompanying products work together to enable users to setup and run testing applications quickly and efficiently. In addition to wide workload coverage, the CalBench provides an organised workspace and a central system for calibration, quality control and management. It can also be utilised for training of instrumentation technicians and engineers. The package can be customised to match site requirements, change pressure ranges or exchange dry block calibrators for different models.
Features
- Advanced instrumentation calibration bench
- Process calibrator/multimeter/PC module
- Source/measure V, I , Ω, frequency & more
- Simulate & measure RTDs, thermocouples
- Calibrate pneumatic, DP, hydraulic pressure
- Includes 2 dry block calibrators
- Pumps, manifolds, fittings, UUT stand
- Fixed & variable DC power supply modules
- Temperature interface module for batch TC calibration
- Automated calibration using EasyCal software
Pressure Calibration
For pressure an automatic controller module is used for pneumatic calibration from vacuum to 20 bar. A selection of precision measurement modules providing range coverage to 700 bar. Additionally dedicated differential pressure modules enable low range DP calibration. Accompanying pneumatic and hydraulic pumps are supplied. Calibrate pressure instrumentation such as:
- Analogue and digital gauges, indicators, manometers
- Calibrators, sensors, transducers, transmitters
- Switches, valves, controllers, chart recorders
Temperature Calibration
The CBP-PROC1 enables users to perform efficient calibration of temperature instrumentation. EasyCal can control the supplied dry block calibrators whilst reading back the temperature measurement of the sensor under test on the 8060 module. Additionally the 7085A scanner module enables multi-channel measurements to be performed. Calibrate various products including:
- Sensors, transmitters, indicators, thermometers
- RTDs, thermocouples, recorders, controllers
- Process calibrators, PRTs, thermistors
Additional Applications
The CBP-PROC1 is a primarily a process instrumentation calibration system, but can also be used to check and verify functions on electrical test equipment and other devices. The CalBench is also ideal for training and can show a wide range of testing applications common to industries.
- Test process calibrators, mV/mA meters, decade boxes, flow totalizers
- Calibrate DP flow transmitters, pulse meters, tachometers, counters
- Train engineers & technicians instrumentation calibration
- Run a complete calibration program with EasyCal software
EasyCal Calibration Software
The CBP-PROC1 comes with EasyCal software on the 8060 control centre. This enables software driven testing procedures and provides increased speed of calibration and consistency of results.
Produce traceable calibration certificates and test reports for quality standards with additional uncertainty information for ISO 17025 conformance.

Details
Downloads
| File Name | File Size | Language | Format |
|---|---|---|---|
|
630 kB |
EN |
|
|
11.5 MB |
EN |
|
Request a price quote
CBP-PROC1 CalBench Package
- Product Ranges
- Decade Boxes
- Portable Voltage & Current Calibrators
- Electrical Multifunction Calibrators
- ATE / Bench Calibrators & Multimeters
- Electrical Test Equipment Calibrators
- Process Calibration Instruments
- Pressure Calibration Instruments
- Calibration Benches
- Calibration Software
- Accessories
- Discontinued Products
- Products by Function
- Calibration Benches
- Industries
- Services
- Resources
- About
- Contact




