MENU
UK
  • EN
  • FR
  • ES
Search
Tel: +441732355993

1006 DC Millivolt Source

1006 DC Millivolt Source & Calibrator
  • 1006 DC mV Source

Features

  • 3 ranges up to 1 V
  • 0.02 % accuracy
  • 20 mA output current
  • Short circuit/overload protection
  • Safety terminals
  • 100 hours typical battery life
  • Supplied with protective cover

1006 Images

  • The 1006 is an accurate handheld millivolt source suitable for voltage injection applications. Three output ranges are provided to give adjustable output values from 1 µV to 1 V with a basic 0.02 % accuracy. For signal injection, the operator needs to switch on, check the battery condition, select the range, and set the required voltage using the thumbwheel switches. The 1006 uses a precision reference diode and low temperature coefficient resistors to give a highly stable output.

    Power is provided by 6 AA batteries. Battery life is several months, depending on usage. The battery condition is monitored by an indicator mounted on the top of the unit. The 1006 has up to 20 mA drive current and is short circuit and overload protected. An off/normal/reverse output polarity switch is provided.

    Safety Terminals
    Fitted as standard and fully compatible with 4 mm shrouded plugs, as well as standard plugs, bare wires, and spade terminals.

    Added Protection
    The 1006 comes fitted with an ergonomic rubber cover providing increased protection and durability. It has a textured grip for comfortable handling and openings at the top and bottom to allow access to the battery meter and a position to place labels if required. It is easy to remove if the user prefers a stand-alone unit or to house the 1006 in the 9027 carry case.

    Applications
    As an accurate millivolt source, the 1006 can be used for many applications including thermocouple simulation (using appropriate lookup table), chart recorder calibration, A/D converter and DMM calibration, and as a stable voltage for backing off DC offsets.

    The 1006 is an easy to use calibration instrument designed for accuracy and reliability. As part of the Time Electronics portable test equipment range it is ideal for use in the lab or field. 

  • Technical Specifications

    Output

    0 to 999.9mV in 3 ranges:
    1 V range: 0 to 999.9 mV in 0.1 mV steps.
    100 mV range: 0 to 99.99 mV in 10 μV steps.
    10 mV range: 0 to 9.999 mV in 1 μV steps.

    Accuracy

    ± (0.02 % of setting + 0.02 % of range + 1 μV).

    Output Resistance

    Less than 0.2 Ω on 1 V and 100 mV ranges. 1 Ω on 10 mV range.

    Maximum Output Current

    1 V and 100 mV ranges: 20 mA. 10 mV range: Up to short circuit value although it should be noted that loads of less than 1 kΩ will give greater than 0.1 % error.

    Output Voltage Stability

    Less than 60 ppm/°C.  Less than 100 ppm per 3 months (non-cumulative).

    Output Polarity

    Positive or negative switch selected.  A centre ‘off’ position is also provided.

    Output Noise Level

    Less than 30 ppm of full scale

    Reference Source

    Precision zener diode, selected for stability and low temperature coefficient.

    Maximum Overload

    The instrument can withstand continuous short circuit on the output for all ranges.

    Power Supply

    6-AA size (51 x 14 mm) batteries. A battery condition display indicates when the batteries should be changed.
    An alternative power source is 6 NiMH cells of the same dimensions. These can be recharged via a socket on the top of the unit. The 6 rechargeable batteries and mains recharger are available as an optional extra.


    General Specifications

    Operating Temperature

    –10 °C to 60 °C

    Dimensions

    H 200 x W 75 x D 110 mm (H 215 x W 100 x D 120 mm including protective boot)

    Weight

    0.75 kg (1.1 kg including protective boot)

    Supplied With

    Protective cover (fitted), 6 x AA batteries (installed), and user manual

    Optional Extras

    Carry case, rechargeable battery pack (240 V or 110 V mains), traceable and accredited calibration certificates

    Country of Origin UK
  • Models

    1006

    DC MilliVolt Source

    Options

    9027

    Leather carry case

    9529

    Rechargeable battery pack - (6 NiMH cells + 230 V mains charger)

    9528 Rechargeable battery pack (6 NiMH cells + 110 V mains charger)

    C150

    Traceable calibration certificate (Factory)

    C100 Accredited calibration certificate (ISO 17025)

    Also available: 1007 DC Millivolt Potentiometer and Source

  • PDF Downloads
    File Name Language

    1006 Data Sheet

    EN

    1006 & 1007 User Manual

    EN

    Carry Case Option Data Sheet EN
  • Request for Quotation

    1006 DC Millivolt Source

    Product Options
    1.20

Related Products

  • 1007 DC Millivolt Potentiometer & Calibrator

    • 3 ranges up to 1V
    • 0.02% accuracy
    • 20mA output current
    • Short circuit/overload protection
    • LED null measuring facility
    • 100 hours typical battery life
    • Portable with protective cover
    View 1007
  • 1010 DC Voltage Calibrator

    • 0.01μV to 10V in 5 ranges
    • 0.02% accuracy
    • Battery or mains operation
    • 30mA output current
    • 10ppm/hr stability
    • Battery level indicator
    • Safety terminals
    View 1010
  • 1017 Voltage / Current / Resistance Calibrator

    • DC Volts 10 nV to 100 V
    • DC Current 100 nA to 100 mA
    • Resistance 10 mΩ to 10 kΩ
    • 0.005 % (50 ppm) accuracy
    • 1 ppm setting resolution
    • Noise < 2 ppm (0.1 to 1 Hz)
    • Stability <5ppm/day, <25ppm/yr
    View 1017
  • 1044 Voltage and Current Calibrator

    • Measure voltage and current
    • Source voltage and current
    • 0.05% accuracy
    • 0 to 20V in 3 ranges
    • 0 to 20mA in 3 ranges
    • Battery power 9V PP3
    • Portable with carry case
    View 1044