Products commonly used in this industry

  • Electronics

    5075 7.5 digit Multimeter

    • 7.5 digit resolution
    • AC/DC voltage and current
    • Resistance and temperature
    • Capacitance
    • Frequency
    • 18 ppm best accuracy
    • 10 channel scanner option
    View 5075
  • Electronics

    5025E Multifunction Calibrator

    • 40 ppm precision calibrator
    • 0 to 1050 V AC/DC voltage
    • 0 to 22 A AC/DC current
    • Resistance and capacitance
    • Thermocouple and Pt100 simulation
    • Clamp meter and power calibration
    • Optional oscilloscope calibration
    View 5025E
  • Electronics

    5025C Multifunction Calibrator

    • 15 ppm precision calibrator
    • 0 to 1050 V AC/DC voltage
    • 0 to 22 A AC/DC current
    • 1 Ω to 1.1 GΩ variable resistance
    • Thermocouple and Pt100 simulation
    • Clamp meter and power calibration
    • Capacitance and inductance
    View 5025C
  • Electronics

    1044 Voltage and Current Calibrator

    • Measure voltage and current
    • Source voltage and current
    • 3 voltage ranges 0 to 20 V
    • 3 current ranges 0 to 20 mA
    • Accuracy 0.05 %
    • 4.5 digit LCD display
    • Portable with 28 hours typical battery life
    View 1044
  • Electronics

    1051 Resistance Decade Box

    • 0.01 Ω to 1 MΩ
    • High accuracy and stability
    • Simple operation with clear visual indication
    • Suitable for Pt100 simulation
    • Low temperature coefficient
    • Safety terminals
    • Removable protective cover
    View 1051
  • Electronics

    1040 Resistance Decade Box

    • 1 Ω to 100 MΩ
    • High accuracy
    • Clear visual indication
    • High stability
    • Safety terminals
    • Low temperature coefficient
    • Supplied with protective cover
    View 1040
  • Electronics

    1041 Resistance Decade Box

    • 0.01 Ω to 1 kΩ
    • 10 mΩ resolution
    • Ideal for PRT and RTD
    • High stability
    • Safety terminals
    • Low temperature coefficient
    • Supplied with protective cover
    View 1041
  • Electronics

    1049 Pt100 Simulator

    • –200 °C to +800 °C
    • ± 0.3 °C accuracy
    • Based on ITS 90 EN 60751
    • 23 set points
    • Exceeds class A
    • Good temperature stability
    • Passive resistance source
    View 1049
  • Electronics

    1053 Inductance Decade Box

    • 1 mH to 10 H
    • In-line readout
    • 3 % accuracy
    • High stability
    • Safety terminals
    • Fully screened
    • Robust and portable
    View 1053
  • Electronics

    1061 Resistance Decade Box

    • 1 Ω to 1.2 MΩ
    • In-line readout
    • Stable metal film resistors
    • Mechanically and electrically robust
    • Ideal for education and electronics
    • Safety terminals
    • Fully screened
    View 1061
  • Electronics

    1065 Power Resistance Decade Box

    • 0.1 Ω to 120 kΩ
    • 1 % accuracy
    • 10 W per resistor dissipation
    • Residual resistance < 20 mΩ
    • In-line readout
    • Mechanically/electrically robust
    • Fully screened
    View 1065
  • Electronics

    1067 Precision Resistance Decade Box

    • 10 mΩ to 12 kΩ
    • 0.01 % accuracy
    • Precision Pt100 simulation
    • 6 digit resolution
    • Better than 20 ppm/year stability
    • Residual resistance < 10 mΩ
    • Fully screened
    View 1067
  • Electronics

    1071 Capacitance Decade Box

    • 10 pF to 100 μF
    • 1 % accuracy
    • In-line readout
    • Colour coded digits
    • Safety terminals
    • Bi-polar working
    • Supplied with protective cover
    View 1071
  • Electronics

    5018 Programmable DC/AC V/I Calibrator

    • 0 - 22 V DC (30 V DC optional)
    • 0 - 22 V AC, 220 V & 1 kV DC options
    • Optional 0 - 220 mA AC/DC
    • Ramping feature
    • GPIB / RS-232 / USB interfaces
    • Ideal for ATE applications
    • EasyCal Software compatible
    View 5018
  • Electronics

    5030 Electrical Tester Calibrator

    • RCD: 3 to 2500 mA, 10 to 2000 ms
    • Loop 50 mΩ to 1.8 kΩ
    • Insulation up to 2 GΩ / 1 kV
    • Continuity 0.1 Ω to 10 kΩ
    • RS-232 / USB Control
    • Fast and intuitive user interface
    • Regional test sockets available
    View 5030
  • Electronics

    5065 6.5 digit Multimeter

    • DC V to 1000 V, AC V to 750 V
    • AC/DC current to 3 A
    • Two and four wire resistance
    • Frequency from 3 Hz to 300 kHz
    • Period and diode measurement
    • Temperature measurements
    • USB interface, optional GPIB
    View 5065
  • Electronics

    5069 Insulation Tester Calibrator

    • 100 kΩ to 100 GΩ
    • Basic accuracy 1 %
    • Up to 10 kV operation
    • Portable with battery operation
    • Fully shrouded safety connectors
    • Display of open circuit voltage
    • Display of short circuit current
    View 5069
  • Electronics

    5077 Power Calibrator

    • Single-phase power simulation
    • Simultaneous supply of voltage & current
    • Up to 1050 V AC/DC, 22 A AC/DC
    • Up to 22 kVA or 22 kW
    • Phase angle ± 90°, PF 0.00 to 1.00
    • 40 to 400 Hz in 0.01 Hz steps
    • 100 A AC current transformer option
    View 5077