5069 Insulation Tester Calibrator

5069 Insulation Tester Calibrator
  • 5069 Insulation Tester Calibrator
  • Insulation Tester Calibrator 5069 panel
  • Insulation Tester Calibrator 5069 typical connection

Features

  • 100 kΩ to 100 GΩ
  • Basic accuracy 1 %
  • Up to 10 kV operation
  • Portable with battery operation
  • Fully shrouded safety connectors
  • Display of open circuit voltage
  • Display of short circuit current

5069 Images

  • A precision instrument suitable for calibrating and testing general purpose insulation testers and megohmmeters with test voltages up to 10 kV.

    It is constructed in a high strength co-polymer plastic case and is powered by a rechargeable battery. This ensures full isolation from the mains and prevents stray leakage.

    The insulation tester being calibrated can be tested for open circuit voltage and short circuit current. These are displayed on the digital meter mounted on the front panel. The insulation resistance is provided by a precision 4 dial decade resistance bank which can be set to a maximum of 99.99 GΩ with additional resistance values of 100 kΩ, 200 kΩ, 500 kΩ, 1 MΩ, 2 MΩ and 5 MΩ which can be switched in as required.

    Rugged and portable, the 5069 is ideal for site calibration work. Also available is the 5068 InsCal Insulation Test Calibrator, 2.5 kV version, and for additional electrical testing capabilities the 5030 calibrator is an excellent solution.

  • Technical Specifications

    Resistance 10 GΩ, 1 GΩ, 100 MΩ, 10 MΩ decade ranges.
    Fixed Values 5 MΩ, 2 MΩ, 1 MΩ, 500 kΩ, 200 kΩ, 100 kΩ.
    Resistance Accuracy 100 kΩ to 5 MΩ = 1%. 10 MΩ to 10 GΩ = 1%. 10 GΩ to 100 GΩ = 5%.
    Resistance Temperature Coefficient Less than 250 ppm per °C
    Open Circuit Voltage Measure 0 to 2 kV range, accuracy 1 % FS. 0 to 10kV range, accuracy 2 % FS.
    Voltage Display 1.999 kV full scale, and 10 kV full scale.
    Short Circuit Current Measure 0 to 2 mA range and 0 to 20 mA range = 1 % FS accuracy.
    Current Display 1.999 mA full scale, and 19.99 mA full scale.


    General Specifications

    Power Internal battery, 6 V re-chargeable NiCad, > 150 hrs between charges.
    Dimensions W 406 x H 175 x D 330 mm
    Weight 4.4 kg
    Supplied With Safety connection leads with bare end to allow custom probes (10 kV rated), 4 mm 5 kV test lead set, pouch to carry test leads, and mains charger.
    Optional Extras Calibration certificates traceable NPL and UKAS
    Country of Origin UK
  • Models

    5069

    INSCAL: Insulation Tester Calibration System (100 kΩ to 100 GΩ, up to 10 kV operation)

    5068

    INSCAL: Insulation Tester Calibration System (100 kΩ to 10 GΩ, up to 2.5 kV operation). View web page

    Options

    C189

    Factory Calibration Certificate (NPL traceable)

    C112 UKAS Calibration Certificate (ISO 17025)
  • PDF Downloads
    File Name File Size Language

    5069 Data Sheet

    215kB

    EN

    5069 User Manual

    325kB

    EN

    5068 Data Sheet

    215kB

    EN

  • Request for Quotation

    5069 Insulation Tester Calibrator

    Product Options
    1.20

Related Products

  • 5025C Multifunction Calibrator

    • 15ppm precision calibrator
    • Calibrate up to 6.5 digit meters
    • 11 standard functions 
    • 0 - 1050V & 0 - 22A (AC/DC)
    • Resistance & capacitance
    • Thermocouple/PT100 simulation
    • Oscilloscope & power options
    View 5025C
  • 5068 Insulation Tester Calibrator

    • 100KΩ to 10GΩ
    • Basic accuracy 1%
    • Up to 2.5kV operation
    • Battery operation
    • Fully shrouded safety connectors
    • Display of open circuit voltage
    • Display of short circuit current
    View 5068
  • 5070 Micro-ohm Meter Calibrator

    • Calibrate ductor testers
    • Calibrate micro-ohm meters
    • 0.2, 2, 20, 200, 2000mΩ
    • 5 cal points: 0/25/50/75/100%
    • Gold plated terminals
    • Low thermal emf connection
    • Portable robust carrying case
    View 5070
  • 5080 PAT Calibrator

    • Calibrate PAT Testers
    • Calibrate VDE0701 testers
    • Battery powered
    • LCD display of voltage & current
    • Safety interlock feature
    • Earth bond currents up to 50A AC
    • Load test currents up to 13A AC