5080 PAT Calibrator

5080 PAT Calibrator
  • 5080 PAT calibrator

Features

  • Calibrate PAT Testers
  • Calibrate VDE0701 testers
  • Battery powered
  • LCD display of voltage & current
  • Safety interlock feature
  • Earth bond currents up to 50A AC
  • Load test currents up to 13A AC

5080 Images

  • A precision calibrator designed to provide rapid high accuracy calibration of portable appliance testers and insulation/continuity testers.
    The 5080 PAT calibrator has functions for earth bond, insulation, leakage, touch leakage, and load test.  

    Housed in a robust safety case the 5080 is easily portable and ideal for field calibration work. It is battery powered, which ensures isolation and prevents inaccuracies due to stray leakage. Features include safety interlock that prevents contact with earth bond studs during insulation and leakage tests, and an LCD display for voltage and current.

    The 5080 is a dedicated solution for PAT testers and part of the electrical testing calibration range from Time Electronics. Other models include the 5030 electrical tester calibrator for RCD, loop, insulation, earth testers and multifunction installation testers. For insulation testers the 5069 InsCal is a portable instrument with resistance up to 100GOhm, and 10kV operation.

  • Technical Specifications

    Earth Bond: Calibrated low value resistive loads

    Values / Accuracy

    20mΩ, accuracy 5%
    190mΩ, 210mΩ, 950mΩ, 1.050mΩ, 1.08Ω, 2Ω, 10Ω, 18Ω, accuracy 1%

    Open circuit voltage measurement

    Range: 0 to 20V
    Accuracy: 0.25% of full scale

    High current AC measurement

    Range: 0 to 50A AC
    Accuracy: 0.5% of reading +/- 0.2A

    Low current AC measurement

    Range: 0 to 2A AC
    Accuracy: 0.5% of reading +/- 2mA

    Low current DC measurement

    Range: 0 to 2A DC
    Accuracy: 1% of reading +/- 2mA

    Insulation: Calibrated high value resistive loads

    Values / Accuracy

    95kΩ, 105kΩ, 500kΩ, 950kΩ, 1.05MΩ, 5MΩ, 10MΩ, accuracy 0.1%
    20MΩ, 50MΩ, 100MΩ, accuracy 1.0%

    Open circuit voltage measurement

    Range: 0 to 1kV DC
    Accuracy: 0.25% of full scale

    Current measurement Range: 0 to 20mA DC. Accuracy: 0.25% of full scale
    Leakage: Resistive loads for leakage current
    Nominal Leakage Currents At 230V AC of 0.5, 1, 2, 5, 10, 15mA

    Mains voltage measurement

    Range: 0 to 500V AC
    Accuracy 0.25% of full scale

    Leakage current measurement

    Range: 0 to 20mA AC
    Accuracy 0.25% of full scale

    Touch Leakage: Constant current source for touch leakage meters
    Current 1.9mA AC 50 +/-5 Hz, into 2K2 maximum load resistance
    Current measurement Range: 0 to 2mA AC. Accuracy: 0.25% of full scale
    Load Test: Connection of external load via an IEC connector

    Mains voltage measurement

    Range: 0 to 500V AC
    Accuracy: 0.25% of full scale

    Load current measurement

    Range: 0 to 13A AC
    Accuracy: 0.5% of full scale


    General Specifications

    Power Internal battery 6V re-chargeable NiCad, >200 hrs between charges.
    Dimensions W406 x H175 x D330mm
    Weight 5.5kg
    Supplied With 4mm terminal box adaptor, 110V adaptor, IEC connector (for external load), battery charger, and user manual.
    Optional Extras Calibration certificates traceable NPL and UKAS
    Country of Origin UK
  • Models

    5080

    PATCAL – Portable Appliance Tester Calibrator

    Options
    C188 Factory Calibration Certificate (NPL traceable)
    C135 UKAS Calibration Certificate (ISO 17025)
  • PDF Downloads
    File Name File Size Language

    5080 Data Sheet

    225kB

    EN

  • Request for Quotation

    5080 PAT Calibrator

    Product Options
    1.20

Related Products

  • 5030 Electrical Tester Calibrator

    • RCD: 3 - 2500mA, 10 - 2000ms
    • Loop 50mΩ to 1.8kΩ
    • Insulation up to 2GΩ / 1kV
    • Continuity 0.1Ω to 10kΩ
    • RS-232 / USB Control
    • Fast and intuitive user interface
    • EasyCal software compatible
    View 5030
  • 5068 Insulation Tester Calibrator

    • 100KΩ to 10GΩ
    • Basic accuracy 1%
    • Up to 2.5kV operation
    • Battery operation
    • Fully shrouded safety connectors
    • Display of open circuit voltage
    • Display of short circuit current
    View 5068
  • 5069 Insulation Tester Calibrator

    • 100 kΩ to 100 GΩ
    • Basic accuracy 1 %
    • Up to 10 kV operation
    • Portable with battery operation
    • Fully shrouded safety connectors
    • Display of open circuit voltage
    • Display of short circuit current
    View 5069
  • 5070 Micro-ohm Meter Calibrator

    • Calibrate ductor testers
    • Calibrate micro-ohm meters
    • 0.2, 2, 20, 200, 2000mΩ
    • 5 cal points: 0/25/50/75/100%
    • Gold plated terminals
    • Low thermal emf connection
    • Portable robust carrying case
    View 5070