
The CBP-TRN2 CalBench is a dual user workstation for instrumentation test and training work. Students can work side by side to practice various applications relating to commissioning, calibration and maintenance of the typical devices used for measurement in process and oil & gas industries.
The CalBench console is configured with 2 sets of identical modules fitted to each side. This makes a combined solution for two students to work on tasks at the same time. 8060 modules provide source, simulation and measurement of process signals, HART communication and 24 V loop power. Each features a PC control centre with 12.1" touch screen display, running the calibrator control application. EasyCal software is available as an option, to enable automated calibration and test management.
For pressure, regulated pneumatic modules with digital gauges are used for 0 to 7 bar (100 psi) controlled output. Additional modules include two variable DC power supplies and two dual AC power socket modules situated and each end of the console.
The package has various extras to aid training applications and create an ergonomic workspace. These include perfo panel hooks, document holder, and shelves. Calibration accessories include an adaptors/fittings kit, and an instrumentation test stand with manifold, vice and transmitter bracket.
Features
- Dual user test & trainer CalBench package
- For 2 students, side by side operation
- 2 x process calibrator/control centres
- 2 x variable DC power supply modules
- 2 x regulated pressure calibrator modules
- Accessories for UUT connections & setup
- Perfo options for storage, document holders
- Comprehensive pressure fittings/adaptors kits
- Configurable instrumentation test stands
- Mobile storage cabinet included

Process and Temperature Calibration
The CBP-TRN2 package features two 8060 process calibrator modules for test and calibration of process instrumentation. With a simple operation touch screen interface, users can source and measure mV, mA, ohms, frequency, and pulses. Simulate and measure thermocouples and RTDs. Calibrate various products including:
- Sensors, indicators, thermometers, recorders
- RTD & thermocouple transmitters, controllers
- Process calibrators, loop current devices
- Add a dry block calibrator for temperature sourcing

Pressure Calibration
Each student has a regulated calibrator module covering 0 to 7 bar (100 psi). These situate next to to the 8060 process calibrator on either side of the console. Practice pressure instrumentation testing of devices such as:
- Analogue and digital gauges, indicators, manometers
- Calibrators, sensors, transducers, transmitters
- Switches, valves, controllers, chart recorders

Turnkey Training Centres
The CBP-TRN2 is a system suitable for use in training centres, workshops and classrooms. We can design and supply complete facilities featuring CalBenches for the technical education workload. Additional requirements for storage or specific applications can be included.
- Complete facility design and supply service
- Consultation on requirements, create drawings and documentation
- Integrate CalBenches like the CBP-TRN2 for a multi-user setup
- CBP-TRN1 CalBench package for teachers
EasyCal Calibration Software
The CBP-TRN2 features two 8060 process calibrator and control centre modules. EasyCal software is available as an option to enhance the system and enable software driven testing to be performed.
Produce calibration certificates and test reports. Students can practice the complete calibration process to help gain an understanding of traceability, automation and document control.

Details
Downloads
File Name | File Size | Language | Format |
---|---|---|---|
890 kB |
EN |
|
11.5 MB |
EN |
|
Request a quote
CBP-TRN2 CalBench Package
- Product Ranges
- Decade Boxes
- Portable Voltage & Current Calibrators
- Electrical Multifunction Calibrators
- ATE / Bench Calibrators & Multimeters
- Electrical Test Equipment Calibrators
- Process Calibration Instruments
- Pressure Calibration Instruments
- Calibration Benches
- Calibration Software
- Accessories
- Discontinued Products
- Products by Function
- Calibration Benches
- Industries
- Services
- Resources
- About
- Contact