
A CalBench package that provides users with modules and extras for the calibration of electrical and electronic test tools, instruments and devices. It allows users to test and maintain a wide range of instruments commonly used by engineers in industrial plants, with a high level of automation to ensure rapid turnarounds.
The system features the 7051+ multifunction calibrator module with 12.1" control centre display. This module combines a high performance electrical calibrator (source) with a 6.5 digit multimeter (measure). It is supplied with a range of accessories for applications and EasyCal software for automated calibration, certificate creation and more.
Users can access the wide range of functions and features from one ergonomic and organised workspace. The control centre situates centrally in the console with communication to various modules. These include a 6 GHz frequency counter with power meter, and 100 MHz oscilloscope. These are operated via software applications on the control centre. Further modules include variable AC and DC power supplies, a 50 MHz function generator and the 5030B electrical tester calibrator.
Adding to the coverage of the modules is the 5069 insulation tester calibrator and a range of accompaniments for service work. A professional solder and re-work station, service tool kit, ESD mat and magnifying lamp are supplied.
Features
- Calibrate electrical & electronic test tools
- Source/measure V, I , Ω, frequency & more
- Electrical multifunction calibrator module
- Simulate & measure RTDs, thermocouples
- 12.1” touch screen control centre
- Control centre scope & frequency counter
- Variable AC and DC power supply modules
- 50 MHz Function/Arbitrary/Pulse Generator
- Electrical tester calibrator module
- Extras include solder and re-work station
- Service tool case and ESD workstation kit

Calibration Capabilities
The CBP-ELEC1 has automated testing capabilities, enabling users to calibrate a wide range of test equipment including:
- Multimeters, signal sources, clamp meters, data loggers
- Continuity testers, decade boxes, RCL meters
- RCD/loop/earth/ground testers, insulation testers, installation testers
- Oscilloscopes, frequency meters, frequency counters, timer counters
- Transmitters, RTDs, thermocouples (electrical simulation & measurement)

Service and Repair Applications
The CBP-ELEC1 has modules and extras suitable for electrical and electronic diagnostics and repair work. The oscilloscope module is suitable for signal analysis and variable AC and DC power supplies can be used for testing and checking electronic equipment and components.
In addition to module operations the package includes a high performance solder and re-work station, magnifying lamp, circuit board holder, ESD kit with matting, and service tool case. This equipment is used on the bench for service applications commonly required in test facilities performing calibration work.
EasyCal Calibration Software
The CBP-ELEC1 comes with EasyCal software on the 7051 control centre. This enables software driven testing procedures and provides increased speed of calibration and consistency of results.
Produce traceable calibration certificates and test reports for quality standards with additional uncertainty information for ISO 17025 conformance.

Details
Downloads
File Name | File Size | Language | Format |
---|---|---|---|
600 kB |
EN |
|
11.5 MB |
EN |
|
Request a quote
CBP-ELEC1 CalBench Package
- Product Ranges
- Decade Boxes
- Portable Voltage & Current Calibrators
- Electrical Multifunction Calibrators
- ATE / Bench Calibrators & Multimeters
- Electrical Test Equipment Calibrators
- Process Calibration Instruments
- Pressure Calibration Instruments
- Calibration Benches
- Calibration Software
- Accessories
- Discontinued Products
- Products by Function
- Calibration Benches
- Industries
- Services
- Resources
- About
- Contact