Products commonly used in this industry

  • Automotive

    5075 7.5 digit Multimeter

    • 7.5 digit resolution
    • AC/DC voltage and current
    • Resistance and temperature
    • Capacitance
    • Frequency
    • 18 ppm best accuracy
    • 10 channel scanner option
    View 5075
  • Automotive

    5025E Multifunction Calibrator

    • 40 ppm precision calibrator
    • 0 to 1050 V AC/DC voltage
    • 0 to 22 A AC/DC current
    • Resistance and capacitance
    • Thermocouple and Pt100 simulation
    • Clamp meter and power calibration
    • Optional oscilloscope calibration
    View 5025E
  • Automotive

    5025C Multifunction Calibrator

    • 15 ppm precision calibrator
    • 0 to 1050 V AC/DC voltage
    • 0 to 22 A AC/DC current
    • 1 Ω to 1.1 GΩ variable resistance
    • Thermocouple and Pt100 simulation
    • Clamp meter and power calibration
    • Capacitance and inductance
    View 5025C
  • Automotive

    1044 Voltage and Current Calibrator

    • Measure voltage and current
    • Source voltage and current
    • 3 voltage ranges 0 to 20 V
    • 3 current ranges 0 to 20 mA
    • Accuracy 0.05 %
    • 4.5 digit LCD display
    • Portable with 28 hours typical battery life
    View 1044
  • Automotive

    1051 Resistance Decade Box

    • 0.01 Ω to 1 MΩ
    • High accuracy and stability
    • Simple operation with clear visual indication
    • Suitable for Pt100 simulation
    • Low temperature coefficient
    • Safety terminals
    • Removable protective cover
    View 1051
  • Automotive

    1040 Resistance Decade Box

    • 1 Ω to 100 MΩ
    • High accuracy
    • Clear visual indication
    • High stability
    • Safety terminals
    • Low temperature coefficient
    • Supplied with protective cover
    View 1040
  • Automotive

    1049 Pt100 Simulator

    • –200 °C to +800 °C
    • ± 0.3 °C accuracy
    • Based on ITS 90 EN 60751
    • 23 set points
    • Exceeds class A
    • Good temperature stability
    • Passive resistance source
    View 1049
  • Automotive

    5018 Programmable DC/AC V/I Calibrator

    • 0 - 22 V DC (30 V DC optional)
    • 0 - 22 V AC, 220 V & 1 kV DC options
    • Optional 0 - 220 mA AC/DC
    • Ramping feature
    • GPIB / RS-232 / USB interfaces
    • Ideal for ATE applications
    • EasyCal Software compatible
    View 5018
  • Automotive

    5030 Electrical Tester Calibrator

    • RCD: 3 to 2500 mA, 10 to 2000 ms
    • Loop 50 mΩ to 1.8 kΩ
    • Insulation up to 2 GΩ / 1 kV
    • Continuity 0.1 Ω to 10 kΩ
    • RS-232 / USB Control
    • Fast and intuitive user interface
    • Regional test sockets available
    View 5030
  • Automotive

    5051Plus Multifunction Calibration System

    • Combined calibrator/multimeter/PC
    • 0 to 1050 V & 0 to 22 A (AC/DC)
    • Source up to 1 GΩ resistance
    • Thermocouple simulate & measure
    • Pt100 simulate & measure
    • Capacitance and inductance
    • Oscilloscope calibration
    View 5051Plus
  • Automotive

    5065 6.5 digit Multimeter

    • DC V to 1000 V, AC V to 750 V
    • AC/DC current to 3 A
    • Two and four wire resistance
    • Frequency from 3 Hz to 300 kHz
    • Period and diode measurement
    • Temperature measurements
    • USB interface, optional GPIB
    View 5065
  • Automotive

    5069 Insulation Tester Calibrator

    • 100 kΩ to 100 GΩ
    • Basic accuracy 1 %
    • Up to 10 kV operation
    • Portable with battery operation
    • Fully shrouded safety connectors
    • Display of open circuit voltage
    • Display of short circuit current
    View 5069