Products commonly used in this industry
- 
	
		
		5075 7.5 digit Multimeter
View 5075- 7.5 digit resolution
 - AC/DC voltage and current
 - Resistance and temperature
 - Capacitance
 - Frequency
 - 18 ppm best accuracy
 - 10 channel scanner option
 
 - 
	
		
		5025E Multifunction Calibrator
View 5025E- 40 ppm precision calibrator
 - 0 to 1050 V AC/DC voltage
 - 0 to 22 A AC/DC current
 - Resistance and capacitance
 - Thermocouple and Pt100 simulation
 - Clamp meter and power calibration
 - Optional oscilloscope calibration
 
 - 
	
		
		5025C Multifunction Calibrator
View 5025C- 15 ppm precision calibrator
 - 0 to 1050 V AC/DC voltage
 - 0 to 22 A AC/DC current
 - 1 Ω to 1.1 GΩ variable resistance
 - Thermocouple and Pt100 simulation
 - Clamp meter and power calibration
 - Capacitance and inductance
 
 - 
	
		
		1044 Voltage and Current Calibrator
View 1044- Measure voltage and current
 - Source voltage and current
 - 3 voltage ranges 0 to 20 V
 - 3 current ranges 0 to 20 mA
 - Accuracy 0.05 %
 - 3.5 digit LCD display
 - Portable with 28 hours typical battery life
 
 - 
	
		
		1051 Resistance Decade Box
View 1051- 0.01 Ω to 1 MΩ
 - High accuracy and stability
 - Simple operation with clear visual indication
 - Suitable for Pt100 simulation
 - Low temperature coefficient
 - Safety terminals
 - Removable protective cover
 
 - 
	
		
		1040 Resistance Decade Box
View 1040- 1 Ω to 100 MΩ
 - High accuracy
 - Clear visual indication
 - High stability
 - Safety terminals
 - Low temperature coefficient
 - Supplied with protective cover
 
 - 
	
		
		1049 Pt100 Simulator
View 1049- –200 °C to +800 °C
 - ± 0.3 °C accuracy
 - Based on ITS 90 EN 60751
 - 23 set points
 - Exceeds class A
 - Good temperature stability
 - Passive resistance source
 
 - 
	
		
		5018 Programmable DC/AC V/I Calibrator
View 5018- 0 to 22 V DC
 - 220 V and 1 kV DC options
 - 0 to 220 mA AC/DC options
 - 0 to 22 V AC option
 - Ramping feature
 - GPIB / RS-232 / USB interfaces
 - Ideal for ATE applications
 
 - 
	
		
		5030 Electrical Tester Calibrator
View 5030- RCD: 3 to 2500 mA, 10 to 2000 ms
 - Loop 50 mΩ to 1.8 kΩ
 - Insulation up to 2 GΩ / 1 kV
 - Continuity 0.1 Ω to 10 kΩ
 - RS-232 / USB Control
 - Fast and intuitive user interface
 - Regional test sockets available
 
 - 
	
		
		5051Plus Multifunction Calibration System
View 5051Plus- Combined calibrator/multimeter/PC
 - 0 to 1050 V & 0 to 22 A (AC/DC)
 - Source up to 1 GΩ resistance
 - Thermocouple simulate & measure
 - Pt100 simulate & measure
 - Capacitance and inductance
 - Oscilloscope calibration
 
 - 
	
		
		5065 6.5 digit Multimeter
View 5065- DC V to 1000 V, AC V to 750 V
 - AC/DC current to 3 A
 - Two and four wire resistance
 - Frequency from 3 Hz to 300 kHz
 - Period and diode measurement
 - Temperature measurements
 - USB interface, optional GPIB
 
 - 
	
		
		5069 Insulation Tester Calibrator
View 5069- 100 kΩ to 100 GΩ
 - Basic accuracy 1 %
 - Up to 10 kV operation
 - Portable with battery operation
 - Fully shrouded safety connectors
 - Display of open circuit voltage
 - Display of short circuit current
 
 - 
	
		
		CalBench Calibration Benches
View CalBench- Universal calibration systems
 - Electrical/pressure/process
 - Power supplies, DMMs & scopes
 - Multifunction calibrator modules
 - Ideal for on-site test facilities
 - Automatic or manual calibration
 - Complete lab design service