
Our range of pressure modules include low and high pressure calibrators, indicators, and controllers. Calibrator and controller modules receive line pressure to the rear of the consoles, with output via front panel ports. Indicator modules are digital gauges with input from the front of the bench.
For rapid testing of transmitters and gauges, automatic calibration can be performed with connectivity to the CalBench control centre running EasyCal software. All digital pressure modules are EasyCal compatible.
8030B controller modules provide the most automated method for pressure calibration, offering fast and precise setting of pressure for their dedicated applications. Then regulated modules (RMTEG) can be considered semi-automatic with line pressure input then user adjustment and setting.
Indicator modules are measurement only, and most commonly utilised with our range of pneumatic or hydraulic pumps for reference calibration. Hoses, fittings and adaptor kits are also available to complement the system.
-
8030B Automatic Pressure Controller
- Configurable pneumatic controller module
- Up to 3 internal sensors for -1 to 100 bar
- Dual sensor versions to 230 bar
- Accuracy per sensor: 0.01 % FS
- Touch screen user interface
- Virtual control app & EasyCal software
- Barometric reference option
View Data Sheet -
8030B-H Hydraulic Pressure Controller
- 400 bar, 600 , 700 & 1000 bar versions
- Under bench pressure cabinet included
- Control stability 0.005 % FS
- Accuracy 0.01 % FS
- Requires pneumatic drive pressure
- Touch screen user interface
- EasyCal software compatible
View Data Sheet -
8020B Precision Pressure Indicator
- Ranges from -1 to 5000 bar (70,000 psi)
- Configured to end user requirements
- Gauge, absolute, or differential sensors
- Up to 4 internal sensors, multiple external
- Pneumatic or hydraulic operation
- Touch screen interface or EasyCal software
- Accuracy 0.01 % FS (per integral sensor)
View Data Sheet -
RMTEG Digital Gauge with Regulator
- Ranges from vacuum to 300 bar (4350 psi)
- 0.02 % or 0.05 % FS accuracy available
- Pneumatic with regulator
- Gauge, Absolute or Compound versions
- Dual function with output or measurement
- 5 digit display resolution
- 3 times per second measure speed
View Data Sheet -
MTEG Digital Pressure Gauge
- Pressure ranges up to 700 bar (10,000 psi)
- 0.02 % or 0.05 % FS accuracy available
- Gauge, Absolute or Compound versions
- 5 digit resolution
- 3 times per second measure speed
- Fully temperature compensated accuracy
- EasyCal software compatible
View Data Sheet -
XTEG Control Centre Pressure Gauges
- Modules up to 700 bar (10,000 psi)
- Gauge, absolute or differential modules
- 0.02 % FS accuracy
- Interface on CalBench control centre
- EasyCal software compatible
- Fully temperature compensated accuracy
- 3 times per second measure speed
View Data Sheet -
7066 Differential Pressure Calibrator
- 0.2, 2, 5, or 10 bar versions
- Best accuracy 0.04 % of full scale
- Pneumatic
- Calibrate DP transmitters, gauges
- 4.5 digit display
- 5 selectable pressure units
- EasyCal software compatible
View Data Sheet -
7084 Line Pressure Controller
- Versions available up to 200 bar
- Pneumatic self-relieving regulator
- 63mm anti-shock analogue gauge
- Front panel output connection
- Needle isolation valve
- Rear output version for line control
- Simple operation
View Data Sheet
- Product Ranges
- Decade Boxes
- Portable Voltage & Current Calibrators
- Electrical Multifunction Calibrators
- ATE / Bench Calibrators & Multimeters
- Electrical Test Equipment Calibrators
- Process Calibration Instruments
- Pressure Calibration Instruments
- Calibration Benches
- Calibration Software
- Accessories
- Discontinued Products
- Products by Function
- Calibration Benches
- Industries
- Services
- Resources
- About
- Contact