A selection of modules for electrical and electronic testing work on the CalBench. Multimeters provide precision measurement and can be used for a wide range of applications from process to R&D and repairs. Additionally the 7051Plus and 8060Plus calibrator modules feature internal 6.5 digit multimeters that operate via the control centre.
Electrical tester calibrator modules are equivalent to our benchtop models. The 5030B is for RCD and multifunction installation testers, and 5068B for insulation testers. Further modules include the 7033 LCR meter typically used to measure the impedance of a circuit or a device. The 8029 electronic load is for DC power supply testing.
-
5065B Digital Multimeter
- DC V to 1000 V, AC V to 750 V
- AC/DC current to 3 A
- Two and four wire resistance
- Frequency from 3 Hz to 300 kHz
- Period and diode measurement
- Temperature measurements
- EasyCal software compatible
View Data Sheet -
5075B Digital Multimeter
- 7½ digit resolution
- AC/DC voltage & current
- Resistance & temperature
- Capacitance & frequency
- 18 ppm/year accuracy
- 10 channel scanner option
- EasyCal software compatible
View Data Sheet -
5030B Electrical Tester Calibrator
- Test RCD, loop, insulation, installation testers
- RCD 3 mA to 2500 mA, 10 ms to 2000 ms
- Loop 50 mΩ to 1.8 kΩ
- Insulation up to 2 GΩ / 1 kV
- Continuity 0.1 Ω to 10 kΩ
- Fast and intuitive user interface
- Control via EasyCal software
View Data Sheet -
5068B Insulation Tester Calibrator
- 100 kΩ to 10 GΩ
- Basic accuracy 1 %
- Up to 2.5 kV operation
- Fully shrouded safety connectors
- Continuous connection - no arcing
- Display of open circuit voltage
- Display of short circuit current
View Data Sheet -
7033 LCR Meter
- Test Frequency: 10 Hz to 200 kHz
- 3.5 " colour LCD display
- Consecutive test frequency
- Basic accuracy 0.05 %
- Measuring speed up to maximum 25 ms
- Full frequency range or spot Open/Short
- 16 parameter measurement combinations
View Data Sheet -
8029 DC Electronic Load
- Suitable for testing DC power supplies
- 0 to 80 V and 0 to 80 A
- Constant V, I, R and power modes
- 400 W continuous dissipation at 28 °C
- 360 W continuous dissipation at 40 °C
- High resolution & accuracy for level setting
- Built-in transient generator with variable slew
View Data Sheet
EN
- Product Ranges
- Decade Boxes
- Portable Voltage & Current Calibrators
- Electrical Multifunction Calibrators
- ATE / Bench Calibrators & Multimeters
- Electrical Test Equipment Calibrators
- Process Calibration Instruments
- Pressure Calibration Instruments
- Calibration Benches
- Calibration Software
- Accessories
- Discontinued Products
- Products by Function
- Calibration Benches
- Industries
- Services
- Resources
- About
- Contact
