  • The 5065B is a high performance, versatile 6½ digit multimeter module with 19 measurement functions. Low cost, simple operation, stability, and high accuracy make the 5065B an ideal DMM for a variety of applications. In addition high speed means both the sampling rate and the data transfer rate can achieve 2000 readings per second.

    The comprehensive range of features makes the 5065B suitable for test engineers, R&D, service, and calibration technicians. The front panel features a two-line, colour-coded display for easy to read measurements and functions. Control is simple, with common functions selected from a single button press. The 5065 measures AC/DC voltage, AC/DC current, 2 and 4 wire resistance, frequency, period, diode, continuity, thermocouples and RTD. In addition to standard functions many other capabilities such as Min/Max, Ratio/% and Null are included. Memory functions with up to 2000 readings can be stored and recalled. Limit testing with an external output can be configured to signal pass or fail.

    The module features a USB interface enables connectivity to a PC or CalBench control centre. When the 5065B is fitted into a console that features a control centre (CC12, 8060 modules for example), the internal connectivity is configured in the factory prior to delivery. This enable users to work with EasyCal software to control and read back from the multimeter. Optional multi channel signal scanning is possible via the 7085A temperature distribution and scanner module. This is commonly used for multi signal measurements for thermocouples. Further options include test lead sets, GPIB interface, and an RTD probe adaptor.

    Applications
    The 5065B is ideal for applications ranging from testing and calibration to education. In R&D and production environments it can be used to check and test electronic devices, circuitry and components. It can also be utilised to make automated measurements for product validation. In calibration the 5065B is an accurate multimeter for testing electrical and electronic sources. It can also be used for signal measurements on process instrumentation such as transmitters, RTDs and thermocouples. Further applications include repair and service work, and experimental testing work in education and engineering.

    EasyCal Calibration Software
    The 5065B can be controlled via Time Electronics EasyCal software to automate the calibration process. This provides increased speed of calibration and consistency of results. Produce traceable calibration certificates and test reports for quality standards with additional uncertainty information for ISO 17025 conformance.

  • Technical Specifications

    DC Voltage
    Range Resolution Input Resistance Accuracy
    100.0000 mV 0.1 μV > 10 GΩ 0.0050 + 0.0035
    1.000000 V 1.0 μV > 10 GΩ 0.0040 + 0.0007
    10.00000 V 10 μV > 10 GΩ 0.0035 + 0.0005
    100.0000 V 100 μV 10 MΩ 0.0045 + 0.0006
    1000.000 V 1mV 10 MΩ 0.0045 + 0.0010
    DC Current
    Range Resolution Shunt Resistance Accuracy
    10.00000 mA 10 nA 5.1 Ω 0.05 + 0.02
    100.0000 mA 100 nA 5.1 Ω 0.05 + 0.005
    1.000000 A 1 μA 0.1 Ω 0.1 + 0.01
    3.00000 A 10 μA 0.1 Ω 0.12 + 0.02
    AC Voltage
    Range Resolution Frequency (Hz) Accuracy

    100.0000 mV

    0.1 μV

    3 to 5
    5 to 10
    10 to 20 k
    20 k to 50 k
    50 k to 100 k
    100 k to 300 k

    1.00 + 0.04
    0.35 + 0.04
    0.06 + 0.04
    0.12 + 0.05
    0.60 + 0.08
    4.00 + 0.50

    1.000000 V
    to
    750.000 V

    1.0 μV to 1 mV

    3 to 5
    5 to 10
    10 to 20 k
    20 k to 50 k
    50 k to 100 k
    100 k to 300 k

    1.00 + 0.03
    0.35 + 0.03
    0.06 + 0.03
    0.12 + 0.05
    0.60 + 0.08
    4.00 + 0.50

    750 V AC range is limited to 100 kHz.
    AC Current
    Range Resolution Frequency (Hz) Accuracy

    1.000000 A

    1 μA

    3 to 5
    5 to 10
    10 to 5 k

    1.00 + 0.04
    0.30 + 0.04
    0.10 + 0.04

    3.000000 A

    10 μA

    3 to 5
    5 to 10
    10 to 5 k

    1.10 + 0.06
    0.35 + 0.06
    0.15 + 0.06

    Resistance
    Range Resolution Test Current Accuracy
    100.0000 Ω 100 μΩ 1 mA 0.01 + 0.005
    1.000000 kΩ 1 mΩ 1 mA 0.01 + 0.002
    10.00000 kΩ 10 mΩ 100 μA 0.01 + 0.002
    100.0000 kΩ 100 mΩ 10 μA 0.01 + 0.002
    1.000000 MΩ 1 Ω 5 μA 0.01 + 0.002
    10.00000 MΩ 10 Ω 500 nA 0.04 + 0.002
    100.0000 MΩ 100 Ω 500 nA 0.8 + 0.02
    Specification applies to 4 wire mode. 2 wire specifications are x2 the stated accuracy and do not include external lead resistance.

    Diode Test
    1.0000 V


    10 μV


    1 mA


    0.01 + 0.02

           

    Continuity
    1000.00 kΩ


    10 mΩ


    1 mA


    0.01 + 0.03

    Frequency and Period
    Range Frequency (Hz) Accuracy (% of reading)

    100 mV to 750 V

    3 to 5
    5 to 10
    10 to 40
    40 to 300 k

    0.1
    0.05
    0.03
    0.01

    Temperature
    RTD Types Pt100, D100, F100, Pt385 or Pt3916. (Best Accuracy ± 0.08 °C )
    Thermocouple Types J, K, N, T and E (Accuracy ± 0.5 °C ). R & S (Accuracy ± 5 °C )


    General Specifications

    Standard Interfaces RS-232 and USB (GPIB optional)
    Line Power As per CalBench ordered
    Dimensions W295 x H201mm (primary console fitting only).
  • Module

    5065B

    Digital Multimeter Module

    Options
    9714 10 Channel Scanner card
    9715 GPIB Interface (replaces standard fitted RS232 interface)
    9717 RTD Probe Adaptor

    9541

    Basic Test Lead Set

    9796

    Premium Test Lead Set

    C173 Factory Calibration Certificate (NPL traceable)
    C117 UKAS Calibration Certificate (ISO 17025)

    ECFLA

    EasyCal Full License - when purchased with multifunction calibrator/DMM: Discounted full license with 1 year support. 
    For further licenses and EasyCal add-ons see the Easycal web page or PDF brochure

  • PDF Downloads
    File Name File Size Language

    5065B Data Sheet

    600 kB

    EN