8030 Automatic Pressure Controller

  • Overview
  • Specifications
  • Downloads
  • Price request
8030 Automatic Pressure Calibrator

The 8030 is an advanced pressure controller/calibrator suitable for wide workload calibration of pressure devices such as transmitters, sensors and gauges. The standard unit can be configured for multiple ranges from vacuum to 100 bar (1500 psi), integrating up to three high accuracy reference sensors for maximum workload coverage. Additionally a barometric reference option enables absolute pressure emulation. High range dual sensor versions up to 230 bar (3350 psi) are also available.

Due to its fully configurable design, the 8030 offers the maximum flexibility to end user requirements. Accuracy is 0.01 % FS for each internal sensor fitted, and control stability is 0.005 % FS of the active sensor range. This provides the necessary coverage for applications with outstanding accuracy, control and speed for testing applications.

With up to three sensors integrated into the instrument the user is always offered an optimal calibration solution over a very wide pressure range. The 8030 is suitable as a high performance pressure standard in process plants, factories and calibration labs. Routine testing of pressure instrumentation is made quick and simple, whether using the 8030 touch screen display or via EasyCal calibration software.

Features

  • Configurable pneumatic controller
  • Up to 3 internal sensors for -1 to 100 bar
  • Dual sensor versions to 230 bar
  • Accuracy per sensor: 0.01 % FS
  • Touch screen user interface
  • Virtual control app & EasyCal software
  • Barometric reference option
  • Control stability per sensor: 0.005 % FS
  • Gauge, compound, absolute, differential
8030 Pressure Controller

Intuitive User Interface

The 8030 features a colour touch-screen interface with user-friendly menus designed for simple operation, enabling users to quickly learn and master the operation of the module. Manually specifying pressure set points is made simple with clearly defined controls on the display.

The 8030 auto-ranging capabilities enable each sensor to be actuated as pressure increase or decreases, providing optimal control and accuracy when performing applications

8030 Accompanying Products

Supplied Accessories and Options

The 8030 is supplied with a benchtop 2 port manifold (model 7161) and contamination trap (model 7115) as standard. Options include the 7165 compact compressor pumps that can supply pressure up to 70 bar. Vacuum pumps, UUT stands, adaptor kits, fittings and hoses are also available to optimise user set ups and applications.

The 8030 also comes with a virtual control panel software application that provides a simple user interface for remote operation on a laptop or PC. Set and output pressure, and use the primary front panel buttons as per the instrument display.

EasyCal Calibration Software

The 8030 can be controlled via Time Electronics EasyCal software to automate testing procedures. Software driven calibration enables users to perform rapid calibrations on instrumentation such as pressure gauges, sensors and transmitters. 

Produce traceable calibration certificates and test reports for quality standards with additional uncertainty information for ISO 17025 conformance.

EasyCal Calibration Software

Specifications

Technical Specification
General Specification
Options

Request a price quote

8030 Automatic Pressure Controller

Product Options
1.20
EN