MENU
UK
  • EN
  • FR
  • ES
Search
Tel: +441732355993

5025C Multifunction Calibrator

5025C Multi Product Calibrator
  • 5025C Multifunction Calibrator
  • 5025C multimeter calibrator
  • 5025C Calibrator Front Panel Controls
  • 5025C Calibrator - Manual Operation
  • 5025C Calibrator - Terminals
  • 5025C Multifunction Calibrator - Deviation Control
  • 5025C Multifunction Calibrator - Front Panel & Display
  • 5025C Multifunction Calibrator - Manual Control Mode
  • 5025C Multifunction Calibrator - Deviation Control
  • 5025C Multifunction Calibrator - Deviation Control
  • 5025C Multifunction Calibrator - Deviation Control

Features

  • 15ppm precision calibrator
  • Calibrate up to 6.5 digit meters
  • 11 standard functions 
  • 0 - 1050V & 0 - 22A (AC/DC)
  • Resistance & capacitance
  • Thermocouple/PT100 simulation
  • Oscilloscope & power options

5025C Images

  • High Performance Calibration
    A precision multi-product calibrator designed to rapidly calibrate a wide range of test & measurement instruments. With over 11 standard functions the 5025C can accurately test and verify both traditional and new test equipment. It is ideal for companies requiring a calibrator that delivers high performance over wide conditions, with excellent capabilities, functionality, and features for ease of use.

    The 5025C multifunction calibrator is fitted with AC/DC voltage to 1050V, AC/DC current to 22A, digital frequency to 10MHz, decade resistance to 1GΩ, simulated variable resistance from 10Ω to 40kΩ, conductance, capacitance, thermocouple and PT100 simulation.

    An optional enhanced performance pack enables advanced calibration for up to 6.5 digit multimeters. It provides full range variable resistance to 120MΩ, extended temperature functions, extended capacitance, inductance, additional precision high DCV ranges and increased ACV frequency bandwidth. Also available are oscilloscope and power calibration options.

    External adaptors are available for clamp meter calibration (up to 1100A) and optical tachometer calibration. Also available is a power amplifier which increases the 5025C’s AC/DC voltage output drive capabilities to 100mA. This addition allows even the most demanding analogue instruments to be tested.

    Wide Workload Coverage
    The 5025C is designed for multifunction calibration of various instruments and devices; bench and handheld multimeters, frequency meters, ohm meters, AC/DC millivoltmeters, thermocouple and PT100 meters, clamp meters, and many other measurement devices. By adding internal options the 5025C can calibrate oscilloscopes, timer/counters, power meters and more. 

    For more information see the 5025 Series Calibration Capabilities Chart showing the DUT coverage of the 5025E and 5025C calibrators.

    Simple Operation
    Functions and ranges are easily accessed from the front panel. Increase and decrease keys per digit, are used to quickly set the output value. Deviation control then enables the user to finely adjust the output value as a percentage (+/- 9.999%). All this information is shown on a clear, easy to read LED display.

    Virtual Control Software
    The 5025C is supplied as standard with Time Electronics’ windows based Virtual Control Software. It allows quick and direct input of any value required. The remote SCPI command is displayed to help users develop custom applications.

    EasyCal Calibration Software
    Connect the 5025C to a PC/Laptop (via RS-232, USB or GPIB) installed with Time Electronics’ EasyCal software and automate the calibration process. This provides increased speed of calibration and consistency of results. Produce calibration certificates and reports to ISO 9001,ISO 17025, and other international quality standards.

  • Technical Specifications

    Standard Functions
    Function Range / Values Best 1 year Specification
    Voltage DC 0 to ± 1050V ± 15ppm of setting

    Current DC

    0 to ± 22A 
    1100A with clamp meter adaptor (option 9780)

    ± 60ppm of setting

    Voltage AC

    1mV to 1050V (20Hz to 100kHz sine-wave)

    ± 200ppm of setting

    Current AC

    10μA to 22A (20Hz to 5kHz sine-wave)
    100A with current transformer (option 9790)
    1100A with clamp meter adaptor (option 9780)

    ± 0.05% of setting

    Thermocouple Simulation

    -210 to 1820°C. Type J, K, R, T, S, B, E, N

    ± 0.05°C

    Digital Frequency/Period

    0.1Hz to 10MHz / 100ns to 10s

    ± 20ppm of setting

    Conductance

    1s to 1ns (decade values)

    ± 20ppm of setting

    Decade Resistance

    1Ω to 1GΩ (decade values)

    ± 20ppm of setting

    Simulated Resistance 10Ω to 40MΩ (variable) ± 0.02% of setting
    PT100 Simulation -180°C to 850°C ± 0.2°C
    Capacitance 1nF, 10nF, 20nF, 50nF, 100nF, 200nF, 500nF, 1μF ± 0.25% of setting
    Option 9770: Oscilloscope Calibration
    Function Range / Values Best 1 year Specification

    Amplitude

    2mV to 200V and 1mV to 2V 50Ω (Square-wave or DC)

    ± 0.05%

    Frequency/Period

    0.1Hz to 100MHz / 10ns to 10s (fixed values 1, 2, 5 sequence)

    ± 20ppm

    Duty Cycle 3 frequencies: 100Hz, 1kHz, 10kHz, settable from 0 to 100%
    Fast-Rise < 400ps. Bandwidth checking up to 400MHz
         

    Option 9783: Frequency Reference
    For timer/counter calibration 

    0.1Hz to 10MHz enhanced frequency accuracy reference

    ± 0.1ppm

    Option 9769: 2.2GHz Sweep

    50MHz to 2.2GHz levelled sine-wave (0.5, 1, 1.5V pk-pk)

    Amplitude ± 1%, Frequency ± 20ppm

    Option 9797: Power Calibration
    Function Range / Values Best 1 year Specification

    Power

    22A, 1050V, 23kW, 45 to 400Hz

    ACV: 0.03%, DCV: 0.01%.
    ACI: 0.1%, DCI: 0.03%

    Phase/Power Factor ± 90°/ 0.00 to 1.00PF ± 0.3°
    Option 9701: Enhanced Performance Pack (added values/types shown in bold where applicable)
    Function Range / Values Best 1 year Specification
    Full Range Resistance 1Ω to 120MΩ (variable) ± 100ppm of setting

    RTD Simulation

    -180 to 850°C. Type PT100, PT200, PT500, PT1000

    ± 0.03°C

    Extended Thermocouple Simulation

    -210 to 2315°C. Type J, K, R, T, S, B, E, N, C, L, U

    ± 0.05°C

    Extended Capacitance

    1nF, 10nF, 20nF, 50nF, 100nF, 200nF, 500nF, 1μF, 10μF, 20μF, 50μF, 100μF

    ± 0.2% of setting

    Extended AC Voltage Frequency 1mV to 200mV/300kHz, 200mV to 2V/1MHz ± 0.05% of setting
    Enhanced DC High Voltage 20 to 200V and 100 to 1020V additional ranges ± 15ppm
    Inductance 1mH, 1.9mH, 5mH, 10mH, 19mH, 50mH, 100mH, 190mH, 500mH, 1H, 10H ± 0.1% of setting

    For external options please see the Models/Options tab.

    General Specifications

    Warm up 30 minutes to full accuracy
    Standard Interfaces GPIB (IEEE-488), RS-232, USB

    Temp Performance

    Operating: 5 to 45°C. Calibration: 15 to 28°C. Storage: -10 to 50°C

    Operating Humidity

    < 80% non condensing

    Operating Altitude 0 to 3km. Non operating: 3km to 12km
    Line Power 100 to 230V AC 50/60 Hz. 200W maximum
    Dimensions W455 x H155 x D480mm
    Weight 16.5kg
    Country of Origin UK
    Supplied With User manual, RS-232 cable, and USB adaptor/cable

    For a full list of options please see the Models/Options tab.
    For full specifications and further details please see the PDF Data Sheets in the Download tab. 

  • Models

    5025C

    Multifunction Calibrator

    Internal Options

    9701

    Enhanced Performance Pack (Full range variable resistance, extended temperature functions, extended capacitance, inductance, additional precision high DCV ranges and increased ACV frequency bandwidth)

    9797 Power Calibration (0 - 20KW AC and DC)
    9770 Oscilloscope Calibration (1mV - 200V, 0.1Hz - 100MHz)
    9769 Scope 2.2GHz Levelled Sine Generator

    9783

    Oven-Controlled High Stability Frequency Reference (increases frequency accuracy from 20ppm to 0.1ppm)

    External Options and Calibration Certificates

    9762

    Rubidium Frequency Reference (9770 Scope option must be fitted)  -  View data sheet

    9764

    Current Probe Calibration Adaptor (9770 Scope option must be fitted)  -  View data sheet

    5065

    6.5 Digit Bench Multimeter  -  View data sheet  /  View web page

    9780

    Clamp Meter Adaptor (1 & 50 turn coil)  -  View data sheet

    9773

    Optical Tacho Adaptor  -  View data sheet

    9790

    100 Amp AC Current Transformer  -  View data sheet

    9760

    Power Amplifier (60V AC, 90V DC - 100mA)  -  View data sheet

    9766

    External Low Noise Attenuator 1000:1  -  View data sheet

    9767

    External Low Noise Attenuator 100:1  -  View data sheet

    9085 Soft Carry Case for 5025

    9059

    Hard transit case for 5025  -  View data sheet

    9728 19” Universal Rack Mount Kit

    9796

    Premium Test Lead Set  -  View data sheet  (5025C supplied with basic test lead set as standard)

    C220

    Factory Calibration Certificate (NPL traceable)

    C225

    UKAS Calibration Certificate (ISO 17025)

    Calibration Software and Accessories

    ECFLA

    EasyCal Full License - when purchased with multifunction calibrator/DMM: Discounted full license with 1 year support. 
    For further licenses and EasyCal options see the Easycal web page or PDF brochure

    9795

    Printer & Connectivity Kit (Printer, DVD-RW, 4 Port USB Hub, Numeric Key Pad & USB Memory Stick)  -  View data sheet

    9777 Bar Code Reader  -  View data sheet
    9778 Cal and ID Label Printer  -  View data sheet

    9779

    Job and Address Label Printer  -  View data sheet

    9743 PCI - GPIB interface card
    9794 USB - GPIB Adaptor
    9597 GPIB Cable
    ESP1 EasyCal Support Package 1: 1 year email and telephone support. Minor upgrades.
    ESP2 EasyCal Support Package 2: 2 year email and telephone support. Minor upgrades.
    EOT1 EasyCal Online Training Session (Via Remote Desktop)
  • PDF Downloads
    File Name File Size Language

    5025C Data Sheet

    939kB

    EN

    5025C Extended Specifications

    145kB

    EN

    5025 Series Brochure

    5.6MB (Low resolution)

    EN

    5025 Series Brochure

    8.6MB (Higher resolution)

    EN

    EasyCal Brochure

    4MB (Low resolution)

    EN

    EasyCal Brochure

    8MB (Higher resolution)

    EN

    Data sheets for various external options shown in Models/Options tab

  • Request for Quotation

    5025C Multifunction Calibrator

    Product Options
    1.20

Related Products

  • 5025E Multifunction Calibrator

    • 40ppm entry level calibrator
    • Calibrate up to 4.5 digit meters
    • 11 standard functions 
    • 0 - 1050V & 0 - 22A (AC/DC)
    • Resistance & capacitance
    • Thermocouple/PT100 simulation
    • Oscilloscope & power options
    View 5025E
  • 5051+ Multifunction Calibration System

    • Combined calibrator/DMM/PC
    • 0 - 1050V & 0 - 22A (AC/DC)
    • Source up to 1GΩ resistance
    • Thermocouple simulate/measure
    • PT100, C & L, scope calibration
    • Clamp meter calibration
    • EasyCal Software included
    View 5051+
  • 5065 6.5 digit Multimeter

    • Resolution 6 1/2 digits
    • Accuracy: 0.005% DC voltage
    • USB interface
    • Optional GPIB interface
    • Temperature measurements
    • 10 channel scanner option
    • EasyCal software compatible
    View 5065
  • EasyCal Calibration Software

    • Automate the calibration process
    • Control TE calibrators & DMMs
    • Automated planning & scheduling
    • For use with multiple devices
    • 1200+ cal procedures included
    • Management/admin features
    • Easily produce certificates & reports
    View EasyCal