5025 Series Calibration Capabilities Chart

The chart below shows the common DUT's covered by the 5025 series calibrators and accompanying products. For more information on the 5025 calibrators please download the PDF brochure.

In the list below software driven calibration relates to EasyCal Software being able to control the Time Electronics model for automated calibration procedures.

Instrument Type Time Electronics Solution Software Driven Calibration

3.5 Digit Multimeter

5025E / 5025C

Yes

4.5 Digit Multimeter

5025E / 5025C

Yes

5.5 Digit Multimeter

5025C

Yes

6.5 Digit Multimeter

5025C  - with option 9701 performance enhancement pack

Yes

Clamp Meter

5025E / 5025C - with option 9780 clamp meter adaptor

Yes

Ohm Meter

5025E / 5025C

Yes

Optical Tachometer

5025E / 5025C - with option 9773 optical tachometer adaptor

Yes

Volt / Continuity Tester

5025E / 5025C

Yes

Data Logger

5025E / 5025C

Yes

Frequency Meter

5025E / 5025C

Yes

Oscilloscope

5025E / 5025C - with option 9770 scope calibration (9769 2.2GHz sweep required for high range scopes)

Yes

Timer Counter

5025E / 5025C - with option 9770 scope calibration + 9783 timer/counter calibration

Yes

Current Probe

5025E / 5025C - with option 9770 scope calibration + 9764 current probe adaptor

Yes

Power Meter

5025E / 5025C - with option 9797 power calibration

Yes

Thermocouple Meter

5025E / 5025C

Yes

Insulation Tester

5069 Insulation Tester Calibrator

Manual Entry

Micro Ohm Meter

5070 Ductor Tester/ Micro-Ohmmeter Calibrator

Manual Entry

Decade Resistance Box

5065 Digital Multimeter

Yes

Temperature Calibrator

5065 Digital Multimeter

Yes

4-20mA Source Meter

5025E / 5025C and 5065 Digital Multimeter

Yes

Portable Appliance Tester

5080 PAT Calibrator

Manual Entry

RCD Tester

5030 Electrical Tester Calibrator

Yes

Loop Tester

5030 Electrical Tester Calibrator

Yes

Installation Tester

5030 Electrical Tester Calibrator

Yes

Earth Ground Tester

5030 Electrical Tester Calibrator

Yes

DC Power Supply

9758 DC Electronic Load

Manual Entry

Pressure Indicator

TE pressure pump and digital gauge (models by range and accuracy required)

Yes

Pressure Transmitter

TE pressure pump and digital gauge (models by range and accuracy required).
Power supply and 5065 Digital Multimeter for measure capabilities required

Yes

Pressure Gauge

TE pressure pump and digital gauge (models by range and accuracy required)

Yes

Instrument type is based on commonly used products, please check specifications to confirm your DUT is covered by the above TE models.