- Accueil
- Produits
- Calibrateurs de tension et de courant
- 7005 : Calibrateur tension / Courant / Boucle
7005 : Calibrateur tension / Courant / Boucle
Caractéristiques Principales
- Courant: 125mA
- Tension: 25V
- Simulation: 50mA ou 21V
- Précision : 0,01%
- Résolution 1μA ou 1mV
- Rampe et échelons programmables
- Changement gamme automatique
Instrument portable pour la calibration et la simulation de boucles de tension et courant. Le 7005, compact et de haute précision permet la mesure et la simulation.
Technical Specifications
Voltage Source Range Resolution Accuracy Output Current Output Resistance 0 to 21V 1mV ±0.01% of setting ±4mV 50mA < 1Ω Voltage Measure (0 to ±25V, Auto-ranging) Range Resolution Accuracy Measure Load 0 to 5V 0.1mV ±0.01% of reading ±0.4mV 10MΩ 5 to 25V 1mV ±0.01% of reading ±2mV 10MΩ Current Source Range Resolution Accuracy Output Voltage Loop Resistance 0 to 50mA 1μA ±0.01% of setting ±2μA 22V max 1100Ω @ 20mA max Current Measure (0 to ±125mA, Auto-ranging) Range Resolution Accuracy Measure Load 0 to 25mA 1μA ±0.01% of reading ±2μA 24.5Ω 25 to 125mA 10μA ±0.01% of reading ±20μA 24.5Ω Current Sink Range Resolution Accuracy Min external drive Max external drive 0 to 50mA 1μA ±0.01% of setting ±2μA 4V 40V
Summary of FunctionsSource Mode • User programmable ranges - any values between 0 and 50mA or 0 and 21V.
• Fixed ranges are available: 4 to 20mA, 0 to 20mA, sqrt 4 to 20mA, sqrt 0 to 20mA.
• Fine adjustment (inching) is available for precise deviation from the calibration point.
• Manual step output - five calibration points 0%, 25%, 50%, 75%, and 100%
• Automatic step output (up/down) - five cal points with programmable dwell period.
• Ramp output - programmable ramp rate (0 to 20mA/sec or 0 to 20V/sec) programmable dwell period (0 to 1000 seconds)
Measure Mode • Voltage and current measuring capability with 5 digit resolution.
• Ranges: 0 to ±5V and ±5 to ±25V, 0 to ±25mA and ±25 to ±125mA.
• Signal can also be measured as a % of span on ranges: 4 to 20mA, 0 to 20mA, square root 4 to 20mA, square root 0 to 20mA.
• For all measurements a Min/Max recording function is available on demand.
General SpecificationsDimensions
H165 x W90 x D45mm
Weight
0.42kg
Operating Temperature
-10 to 50°C
Storage Temperature -30 to 70°C Operating Humidity 0 to 90% non-condensing at 25°C Power
Internal rechargeable NiMH battery pack. Battery life typically 9 hours. Auto power-down feature can be enabled.
Full recharge from being exhausted will take approximately 16 hours with the unit switched off.Supplied With Battery charger, Mallette de Transport, and Manuel Optional Extras
Calibration certificates traceable to NPL and UKAS
Country of Origin UK Modèles 7005
Calibrateur Tension / Courant / Boucle
Options C184 Certificat de Calibration Usine C195 Certificat de Calibration UKAS (ISO 17025) Téléchargements PDF Nom du fichier Taille du fichier Langue 642kB
EN
Appel d'offre
7005 : Calibrateur tension / Courant / Boucle
Produits connexes
-
1030 : Source Tension / Courant
- Gammes de 10 mV, 100 mV et 1 V
- Gammes de 10 mA et 100 mA
- Précision à 0,1 %
- Tension disponible entre 0 et 8 V
- Cadran tournant de précision
- Alimentation par batterie 9 V PP3
- Indicateur de niveau de la batterie
-
1044 : Calibrateur Tension / Courant
- Mesure de tension et de courant
- Simulation de tension et courant
- Précision : 0,05%
- Tension de 0 à 20V
- Courant de 0 à 20mA
- Alimenté par batterie 9V
- Avec mallette de transport
-
1048 : Calibrateur de boucle
- Mesure de tension et de courant
- Simulation de tension et courant
- 0 à 22mA et 0 à 22V
- 0 à 70 mA et 0 à 50V
- Sortie échelons et rampe
- Ajustement fin
- Précision : 0,02%
-
7006 Loop-Mate 1 : Source et Simulateur de Boucles
- Gammes 4 à 20mA ou 0 à 10V
- 7 Points de réglags
- Précision : 0,1%
- Tx ou test Rx
- Mode de pas automatiques
- Alimenté par batterie 9V type PP
- Alimentation boucle interne