• EN
  • FR
  • ES
Tel: +441732355993

1030 Voltage and Current Source

1030 Voltage and Current Source
  • 1030 Voltage and current source


  • 10mV, 100mV, 1V ranges
  • 10mA, 100mA ranges
  • 0.1% accuracy
  • 0 to 8V available
  • Precision 10-turn dial
  • Battery level indicator
  • Battery powered 9V PP3

1030 Images

  • The 1030 MicroCal is a portable voltage and current calibrator for general purpose signal injection. As part of our portable test equipment range, it is suitable for voltage and current loop signal simulation as well as thermocouple simulation. 

    Being both cost-effective and simple operation make the 1030 a popular instrument that is used in various applications across industries. The compact (115 x 62 x 55mm) and durable design makes it ideal for use in both the lab and field, with carry case supplied as standard. Typical battery life is 60 hours. An optional rechargeable battery pack is available, with mains charger that connects via a socket on the top of the unit. 

    The MicroCal is designed for traditional analogue control. The precision 10-turn dial provides a conventional feel to selecting the required output with a setting resolution of 1 part in a 1000 (0.1%).

    Three voltage ranges give an adjustable output from 10µV to 1V and two current ranges for 10µA to 100mA. An additional 0 to 8V output can be obtained by using a precision 1KΩ resistor that is supplied with the unit. The resistor is connected across the output terminals and the 10mA current range selected.  This allows the output to be set between 0 and +/- 8V with a 10mV resolution and an accuracy of  0.3% of full scale.

    The 1030 is simple to operate and does not require any standardisation prior to use.  The operator needs only to switch on, check the battery condition, and set the required range and output value.

    Accurate measurements of low ohm values, such as platinum resistance thermometers, can be performed by using the 1030 as a current source and measuring the voltage across the load with a digital voltmeter. The 10mV range is ideal for simulation of all types of thermocouple.

    The 1030 is a compact calibration tool, ideal for electrical engineers to test various measurement equipment, temperature controllers, and PLC analog input cards, with mV or mA inputs. As with all models in the Time Electronics handheld calibrator range it is designed for accuracy and reliability, whilst maintaining ease of use.

  • Technical Specifications

    Range Accuracy Resolution Max Output Current Output Resistance
    0 to 10mV 0.2% of full scale 10μV Limited by o/p resistance 10Ω
    0 to 100mV 0.1% of full scale 100μV 20mA 0.2Ω
    0 to 1V 0.1% of full scale 1mV 20mA 0.2Ω

    0 to 8V (using supplied 1kΩ resistor)

    0.3% of full scale


    Limited by o/p resistance


    Range Accuracy Resolution Max Output Voltage
    0 to 10mA 0.2% of full scale 10μA 8V
    0 to 100mA 0.2% of full scale 100μA 8V
    Linearity 0.15%
    Temperature Coefficient 150ppm of full scale per °C (Outside 18°C to 28°C )
    Noise 30ppm of full scale


    PP3 size, 9V. Approximately 60 hours life. An optional alternative power source is a NiMH rechargeable cell of the same type. This can be recharged via the socket on the top of the unit without removing the cell from the unit.

    Battery Condition Monitored by front panel indicator
    Output Polarity Positive or negative, switch selected. A centre ‘off ‘ position is also provided.
    Maximum Overload The 1030 can withstand continuous open circuit or short circuit on all ranges.

    General Specifications


    H115 x W62 x D55mm



    Supplied With

    Leatherette carry case, 1kΩ resistor, 9V PP3 battery (installed), and user manual.

    Optional Extras

    Rechargeable battery packs (240V or 110V mains). 
    Calibration certificates traceable to NPL and UKAS.

    Country of Origin UK
  • Models


    MicroCal - Voltage and Current Source



    Rechargeable Battery Pack (NiMH Battery and 240V Mains Charger)


    Rechargeable Battery Pack (NiMH Battery and 110V Mains Charger)


    Factory (NPL Traceable) Calibration Certificate

    C110 UKAS Calibration Certificate (ISO 17025)
  • PDF Downloads
    File Name File Size Language

    1030 Data Sheet



    1030 User Manual



  • Request for Quotation

    1030 Voltage and Current Source

    Product Options

Related Products

  • 1044 Voltage and Current Calibrator

    • Measure voltage and current
    • Source voltage and current
    • 0.05% accuracy
    • 0 to 20V in 3 ranges
    • 0 to 20mA in 3 ranges
    • Battery power 9V PP3
    • Portable with carry case
    View 1044
  • 1048 Voltage/Current/Loop Calibrator

    • Source/measure current & voltage
    • 3 Source ranges to 22mA or 22V
    • 3 Measure ranges to 70mA or 50V
    • Transmitter simulator/sink
    • Output steps and ramps
    • Fine adjustment (inching)
    • Accuracy 0.02% of span
    View 1048
  • 1077 Milliamp Transducer Simulator

    • 3 operating modes
    • 100mA source and load
    • 24V line mode
    • 0.02% accuracy
    • Safety terminals
    • Battery level indicator
    • Supplied with protective cover
    View 1077
  • 7005 Process Loop Calibrator

    • Loop source/measure - V or I
    • Measure 0 - 25V or 0 - 125mA
    • Source 0 - 21V or 0 - 50mA
    • Accuracy 0.01%
    • Resolution 1μA or 1mV
    • Programmable ranges
    • Manual step, auto-step & ramp
    View 7005