Process Calibration Modules

Process Calibration Modules

Process modules for loop and temperature calibration

A range of CalBench modules that include temperature calibrators and simulators for RTD and Pt100 applications loop calibrators, process communicators and more. These modules are commonly used on the bench when testing transmitters, transducers and sensors.

These modules combine practicality with simple operation for instrumentation testing and diagnostics. For automated calibration the comprehensive 8060 multifunction calibrator and control centre provides the optimal solution for process signal source and measure on the CalBench.

  • Process Calibration Modules

    8060 Multifunction Process Calibrator and Control Centre

    • Source mV, mA, resistance & frequency
    • Measure mV, mA, resistance & frequency
    • Thermocouple simulate/measure (13 types)
    • RTD simulate and measure (11 types)
    • Touch screen control centre, 12.1” display
    • Integral 24 V loop power supply
    • Optional integral 6.5 digit multimeter
    View Data Sheet
    PDF
  • Process Calibration Modules

    7085A Temperature Distribution & Scanner

    • 10 channel scanner for bath T/C testing
    • Cold junction temperature display
    • Records min/max ambient temperatures
    • Interfaces with 8060+ or 7051+ modules
    • Can be used with 5065B multimeter module
    • Clear visual display of temperature (LCD)
    • Suitable for use with dry block calibrators
    View Data Sheet
    PDF
  • Process Calibration Modules

    7001 Pt100 Simulator

    • -200°C to +800°C
    • Accuracy ± 0.3°C
    • 23 set points
    • Temperature coefficient  <30ppm/°C
    • ITS-90 EN60751
    • Exceeds class A
    • Passive resistance source
    View Data Sheet
    PDF
  • Process Calibration Modules

    7067 Loop Calibrator

    • Loop source/measure to V or I
    • Measure 0 to 25 V or 0 to 125 mA
    • Source 0 to 21 V or 0 to 50 mA
    • Accuracy 0.01 %
    • Resolution 1 μA or 1 mV
    • Programmable ranges
    • Manual step, auto-step & ramp
    View Data Sheet
    PDF
  • Process Calibration Modules

    7068 RTD Temperature Calibrator

    • 0.05 °C accuracy, 0.01 °C resolution
    • 0.03 Ω accuracy, 0.01 Ω resolution
    • 2, 3 and 4 wire connections
    • Read and simulate °C, °F, °K, Ω
    • Ramp and step
    • Pt100 plus 7 other RTD types
    • User programmable
    View Data Sheet
    PDF
  • Process Calibration Modules

    7069 Voltage/Current/Loop Calibrator

    • Source/measure voltage & current
    • 3 source ranges to 22 mA or 22 V
    • 3 measure ranges to 70 mA or 50 V
    • Accuracy 0.02 % of span
    • Transmitter simulator/sink
    • Output steps and ramps
    • Fine adjustment (inching) 
    View Data Sheet
    PDF
  • Process Calibration Modules

    7077 Process Calibrator

    • Measure/simulate thermocouples
    • Measure/simulate Pt100
    • Measure/source (µV/mV/mA)
    • Display in °C and °F
    • Automatic CJC - selectable
    • 10 point memory recall
    • Process loops 4-20mA/0-50mA 
    View Data Sheet
    PDF
  • Process Calibration Modules

    7079 Loop Ancilliaries Calibrator

    • Loop measure 0 to 200 mA
    • 0.05 % accuracy, 10 μA resolution
    • 4.5 digit display
    • Continuity test
    • 24 V output, power 4 to 20 mA loops
    • Overload protection to loop
    • RS-232 interface
    View Data Sheet
    PDF
  • Process Calibration Modules

    7002-7003-7004 Hart & Fieldbus Modules

    • 7002 HART communication module
    • 7003 FF communication module
    • 7004 Combined HART & FF module
    • EasyCal applications for HART & FF
    • Smart device calibration & verification
    • Monitoring of primary values
    • Conditioned power
    View Data Sheet
    PDF

EN