7065 Pressure Indicator Module

  • The 7065 is a precision indicator module that can be used for pressure or vacuum calibration. It is a simple operation module ideal for calibrating and cross-checking pressure gauges, sensors, transmitters, transducers, indicators, switches, and many other devices. The following versions are available; 0.2, vacuum to 2, 5, 10, 20, 35, 70, 100, 200, 400, or 600bar.

    Features include a 4.5 digit LCD display, 5 pressure units, zeroing switch and pressure measurement input. Best accuracy is 0.04% of full scale. For input pressure Time Electronics have a range of pumps including the 7194 benchtop pneumatic pump (vacuum to 120bar) and 7195 hydraulic benchtop pump (vacuum to 600bar). Each pump features a double output manifold to enable connection to both the module and device under test. They can be used conveniently on the CalBench worktop to provide a precision pressure source to the 7065 and DUT, with a method that requires minimal user effort.

    The 7065 is fitted as standard with an RS-232 interface which is accessible on the rear of the CalBench console or internally connected to a 7051 calibrator/control centre. This enables communication and read back with EasyCal calibration software (supplied as standard with the 7051 multifunction calibrator/control centre module). With EasyCal the user can define and perform pressure calibration procedures as well as create and print traceable calibration certificates.

  • Technical Specifications

    Specifications are for 1 year at 23ºC ±5ºC. Accuracy includes linearity and long term effects.
    All accuracies are ±1 digit. For operation outside specified temperature range, apply 70ppm per °C
    Pressure
    Range (bar) 0 to 0.2 Vac to 2 0 to 5 0 to 10 0 to 20 0 to 35 0 to 70 0 to 100 0 to 200 0 to 400 0 to 600

    Accuracy (% of fs)

    0.1

    0.04

    0.04

    0.04

    0.04

    0.04

    0.04

    0.04

    0.1

    0.1

    0.1

    Resolution (bar) 0.01mb .0001 .0001 .0001 .0001 0.001 0.01 0.01 0.01 0.1 0.1

    Units

    0.2bar: mbar, PSI, kPa, kg/cm2, cmWg
    Vac to 2, 5, 10 & 20bar: bar, PSI, kPa, kg/cm2, cmWg
    35bar and above: bar, PSI, MPa, kg/cm2, Atm

    Maximum Pressure 2 x range, 1.5 x range for 20bar and above
    Sensor Piezo-resistive - stainless steel diaphragm
    Over pressure warning 1.2 x range full scale - audio and visual (on LCD) warning

    Fittings

    Quick Release (under 20 bar) and Minimess (over 20 bar)


    General Specifications

    Display

    4.5 digit LCD

    Interface

    RS-232 for readback (suitable for use with EasyCal and 7051 multifunction calibrator & control module)

    Module Width

    96mm (primary or secondary console fitting) 

    Optional Extras

    Benchtop pressure pumps, fittings/adaptors kits, EasyCal calibration software, and calibration certificates

    Country of Origin UK
  • Module

    7065

    Pressure Indicator Module (+ pressure range code shown below)

    Pressure Range Ordering Information
    Range (bar) 0.2 Vac to 2 5 10 20 35 70 100 200 400 600

    Range Code

    7100

    7101

    7102

    7103

    7104

    7105

    7106

    7107

    7108

    7109

    7110

    Options

    7193

    Benchtop Pneumatic Pressure Pump (vacuum to 40bar)

    7194

    Benchtop Pneumatic Pressure Pump (vacuum to 100bar) 

    7195

    Benchtop Hydraulic Pressure Pump (vacuum to 600bar)

    7198

    Pressure Adaptors and Fittings Kit

    ECFLA

    EasyCal Calibration Software (see Bench Software)

    C178

    Factory Calibration Certificate (NPL traceable)

    C190 UKAS Calibration Certificate (ISO 17025)
  • PDF Downloads
    File Name File Size Language

    7065 Data Sheet

    344kB

    EN

    7193 Benchtop Pressure Pump Data Sheet

    238kB

    EN

    7194 Benchtop Pneumatic Pump Data Sheet

    340kB

    EN

    7195 Benchtop Hydraulic Pump Data Sheet

    232kB

    EN

    7198 Pressure Adaptors & Fittings Kit Data Sheet

    564kB