5065B Digital Multimeter Module

  • The 5065B is a high performance, versatile 6½ digit multimeter module with 19 measurement functions. Simple operation, long term stability, and high accuracy make the 5065B an ideal DMM for a variety of applications. In addition high speed means both the sampling rate and the data transfer rate can achieve 2000 readings per second. The comprehensive range of features make it suitable for test engineers, R&D, service, and calibration technicians.

    The front panel features a two-line, colour-coded display for easy to read measurements and functions. Control is simple, with common functions selected from a single button press.

    The 5065B measures AC/DC voltage, AC/DC current, 2/4 wire resistance, frequency, period, diode, continuity, thermocouples and RTD. In addition to these standard functions many other capabilities such as Min/Max, Ratio/% and Null are included. Memory functions with up to 2000 readings can be stored and recalled. Limit testing with an external output can be configured to signal pass or fail.

    The USB interface enables connectivity to a PC. A basic setup and graphing application is supplied as standard. Add-in utilities for Microsoft Excel and Word allow simple data collection directly into a spreadsheet or document.

    An optional 10 channel scanner card is available which allows multiple inputs to be measured.Further options include test lead sets, GPIB interface, and an RTD probe adaptor. 

    EasyCal Software
    To automate the calibration process the 5065B can be controlled using Time Electronics' EasyCal software. This provides increased speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards.  

  • Technical Specifications

    DC Voltage
    Range Resolution Input Resistance Accuracy
    100.0000mV 0.1μV > 10GΩ 0.0050 + 0.0035
    1.000000V 1.0μV > 10GΩ 0.0040 + 0.0007
    10.00000V 10μV > 10GΩ 0.0035 + 0.0005
    100.0000V 100μV 10MΩ 0.0045 + 0.0006
    1000.000V 1μV 10MΩ 0.0045 + 0.0010
    DC Current
    Range Resolution Shunt Resistance Accuracy
    10.000000mA 10nA 5.1Ω 0.05 + 0.02
    100.00000mA 100nA 5.1Ω 0.05 + 0.005
    1.000000A 1μA 0.1Ω 0.1 + 0.01
    3.00000A 10μA 0.1Ω 0.12 + 0.02
    AC Voltage
    Range Resolution Frequency (Hz) Accuracy

    100.0000mV

    0.1μV

    3 to 5
    5 to 10
    10 to 20k
    20 to 50k
    50K to 100k
    100K to 300k

    1.00 + 0.04
    0.35 + 0.04
    0.06 + 0.04
    0.12 + 0.05
    0.60 + 0.08
    4.00 + 0.50

    1.000000V
    to
    750.000V

    1.0μV to 1mV

    3 to 5
    5 to 10
    10 to 20k
    20 to 50k
    50K to 100k
    100K to 300k

    1.00 + 0.03
    0.35 + 0.03
    0.06 + 0.03
    0.12 + 0.05
    0.60 + 0.08
    4.00 + 0.50

    AC Current
    Range Resolution Frequency (Hz) Accuracy

    1.000000A

    1μA

    3 to 5
    5 to 10
    10 to 5k

    1.00 + 0.04
    0.30 + 0.04
    0.10 + 0.04

    3.000000

    10μA

    3 to 5
    5 to 10
    10 to 5k

    1.10 + 0.06
    0.35 + 0.06
    0.15 + 0.06

    Resistance
    Range Resolution Test Current Accuracy
    100.0000Ω 100μΩ 1mA 0.01 + 0.004
    1.000000kΩ 1mΩ 1mA 0.01 + 0.001
    10.00000kΩ 10mΩ 100μA 0.01 + 0.001
    100.0000kΩ 100mΩ 10μA 0.01 + 0.001
    1.000000MΩ 5μA 0.01 + 0.001
    10.00000MΩ 10Ω 500nA 0.04 + 0.001
    100.0000MΩ 100Ω 500nA 0.8 + 0.01
           

    Diode Test
    1.0000V


    10μV


    1mA


    0.01 + 0.02

           

    Continuity
    1000.00KΩ


    10mΩ


    1mA


    0.01 + 0.03

    Frequency and Period
    Range Frequency (Hz) Accuracy (% of reading)

    100mV to 750V

    3 to 5
    5 to 10
    10 to 40
    40 to 300k

    0.1
    0.05
    0.03
    0.06

    Temperature
    RTD Types PT100, D100, F100, PT385 or PT3916. (Best Accuracy ±0.08°C )
    Thermocouple Types J, K & T (Accuracy ±0.5°C ). E (Accuracy ±0.6°C ). R, S & B (Accuracy ±5°C )


    General Specifications

    Standard Interfaces RS-232 and USB (GPIB optional)
    Line Power 100 - 230V AC 50/60Hz

    Module Width

    295mm (primary console fitting only) 

  • Module

    5065B

    Digital Multimeter Module

    Options
    9714 10 Channel Scanner card
    9715 GPIB Interface (replaces standard fitted RS232 interface)
    9717 RTD Probe Adaptor

    9541

    Basic Test Lead Set

    9796

    Premium Test Lead Set

    C173 Factory Calibration Certificate (NPL traceable)
    C117 UKAS Calibration Certificate (ISO 17025)

    ECFLA

    EasyCal Full License - when purchased with multifunction calibrator/DMM: Discounted full license with 1 year support. 
    For further licenses and EasyCal add-ons see the Easycal web page or PDF brochure

  • PDF Downloads
    File Name File Size Language

    5065B Data Sheet

    343kB

    EN