  • Integral Calibrator, DMM, Touch Screen PC
  • 0 to 22V AC/DC V / 0 to 220mA AC/DC I
  • 1Ω to1GΩ decade resistance
  • 10MHz digital frequency
  • RTD and thermocouple simulation/measure
  • High voltage/current option: 1kV/22A AC/DC
  • Oscilloscope calibration option
  • Module control software - EasyCal

7051 Images

  • Universal calibration and system control
    Mounted centrally in the primary console the 7051 combines a precision multifunction calibrator, 6½ digit multimeter, and touch screen PC.
    It is the principle module for on-site facilities that require high performance calibration and maximum functionality.

    Calibrator (source)
    Provides a wide range of calibrated outputs for AC/DC voltage and current, RTD and thermocouple simulation, plus a range of resistance and frequency functions. Internal options can be added for increased capabilities. These include high voltage/current, capacitance/inductance, and oscilloscope calibration. Further enhancements can be made by additional side modules, adaptors, and benchtop instruments.

    Digital Multimeter (measure)
    The integral 6½ digit multimeter that can measure DC voltages to 1000V, AC voltages to 750V, resistance to 100MΩ, and frequency to 300kHz.

    PC Control Centre
    The 7051 control centre is a PC with a 64 bit quad core processor, running Windows 8.1, with a 10.4” capacitive touch screen display. An optional PC upgrade with 12.1” display is also available. The calibrator/multimeter control software allows the wide range of functions to be easily selected using mouse, keyboard, or touch screen. 

    EasyCal Software
    EasyCal calibration software is pre-loaded on the 7051 and enables automatic calibration to increase speed and efficiency of work. In addition EasyCal has features to manage and administrate both inventory and quality control. To complement the system a printer and connectivity kit is supplied as standard, for generation of certificates and reports.

    Using EasyCal the operator can read back from compatible electrical, temperature, pressure, and loop modules within the bench. Furthermore the software can be used with external instruments such as dry block calibrators and portable test instruments. 

    The 7051 Plus Package
    A comprehensive package including specific options to cover the calibration requirements for electrical and process applications. As a package it incorporates the full internal capabilities of the 7051, and is complemented by external adaptors for increased functionality. It is suitable for users in need of rapid multi product testing with automated test runs using EasyCal software. Further supplied accessories include a bar code reader for quick identification of devices in EasyCal, and label printer for creating ‘Calibrated’ labels to be placed on instruments.

  • Technical Specifications

    Standard Features - Calibrator (Source)
    Function Range Best 1 year Specification

    Voltage DC

    0 to ± 22V

    ± 15ppm of setting

    Current DC

    0 to ± 220mA

    ± 80ppm of setting

    Voltage AC

    1mV to 22V (10Hz to 20kHz, sine-wave)

    ± 300ppm of setting

    Current AC

    10μA to 220mA (20Hz to 1kHz, sine-wave)

    ± 0.05% of setting

    Decade Resistance

    1Ω to 1GΩ (Fixed values, decade steps)

    ± 20ppm of setting

    Simulated Resistance 10Ω to 40MΩ ± 0.02% of setting
    Conductance 1s to 1ns (Fixed values, decade steps) ± 20ppm of setting
    Thermocouple Simulation -270 to 1800°C (Type J, K, R, T, S, B, E, N) ± 0.15°C

    PT100 Simulation

    -180 to 850°C

    ± 0.2°C

    10MHz Digital Frequency/Period 0.1Hz to 10MHz / 100ns to 10s ± 20ppm of setting
    Standard Features - Internal DMM 6.5 Digit (Measure)
    Function Range Best 1 year Specification
    Voltage DC 0 to 1000V 35ppm of rdg + 6ppm of rng
    Current DC 0 to 3A 500ppm of rdg + 50ppm of rng
    Voltage AC 0 to 750V 0.06% of rdg + 0.04% of rng
    Current AC 0 to 3A 0.1% of rdg + 0.04% of rng
    Resistance 0 to 100MΩ 100ppm of rdg + 50ppm of rng
    Frequency 3Hz to 300kHz 0.01% of rdg
    Thermocouple -270 to 1800°C (Type J, K, R, T, S, B, E, N) ± 0.5°C
    PT100 -180 to 850°C ± 0.08°C
    Standard Features - Internal PC Specifications / Details
    Processor 64 bit, quad core (or equivalent)
    RAM 4GB (or higher)
    Hard Drive 60GB Solid State (or higher)
    Ports 4 x USB, 1 x Fast Ethernet
    Display 10.4” Capacitive Touch Screen LCD
    Operating System Windows 8.1

    Pre-loaded Software

    Calibrator/Multimeter control programs and EasyCal calibration software suite.

    Upgrade Option CC12A: Upgraded integral PC (16GB RAM, 120GB hard drive) and 12.1” touch screen
    Supplied With USB keyboard, Printer, DVD-RW, 4 port USB hub, Numeric key pad, USB Stick

    Internal Calbrator Options / Specifications

    Option (code in brackets) Range / Values Best 1 year Specification

    High Voltage/Current (9782*)

    22V to 1050V AC/DC
    220mA to 22A AC/DC

    DCV: 50ppm. ACV: 0.08%.
    DCI: 250ppm. ACI: 0.2%.

    Wideband AC Voltage (9771*)

    20 to 200mV/300kHz. 0.2 to 2V/1MHz. 2 to 20V/100kHz

    ± 0.05% of setting

    Capacitance (9798*)

    1nF, 10nF, 100nF, 1μF, 10μF, 100μF

    ± 0.25% of setting

    Inductance (9798*)

    1,1.9,5,10,19,50,100,190, & 500mH, 1H, 10H

    ± 0.1% of setting

    Full Range Resistance (9787*)
    - PT100

    1Ω to 120MΩ (Variable)
    -200 to 850°C

    ± 100ppm of setting
    ± 0.2°C

    Oscilloscope Calibration (9770*)
    - Amplitude
    - Frequency/Period
    - Duty Cycle
    - Fast-Rise
    - Internal Freq Reference (9783*)
    - 2.2GHz Sweep (9769)

    6mV to 200V and 6mV to 2V 50Ω (square-wave or DC)
    0.1Hz to 100MHz / 10ns to 10s
    3 frequencies: 100Hz, 1kHz, 10kHz, settable from 0 to 100%
    <400ps. Bandwidth checking up to 400MHz
    0.1Hz to 10MHz / 100ns to 10s
    100MHz to 2.2GHz levelled sine-wave (0.5,1, 1.5V pk-pk)

    ± 0.05%
    ± 20ppm

    ± 0.1ppm
    Amplitude ± 1%, Frequency ± 20ppm

    * denotes options that are included in the 7051 Plus package

    Full details and data sheets on the available external options are shown in the 7051 Options tab.

    General Specifications

    Warm up 30 minutes to full accuracy
    Settling Time Less than 5 seconds
    Temp Performance Operating: 5 to 40°C, Full Spec: 22°C +/- 3°C, Storage: -10°C to 50°C
    Operating Humidity <80% non condensing
    Operating Altitude 0 to 3km. Non operating: 3km to 12km
    Line Power 100 to 230V AC 50/60 Hz. 200W maximum

    Module Width

    425mm (mounted centrally in primary console)

    Supplied With

    USB keyboard and mouse, printer and connectivity kit, premium test lead set, EasyCal calibration software, manual control software programs for calibrator and DMM, and user manuals.

  • Module


    Multifunction Calibrator and Control Centre - Features and included items:
    • Precision Multifunction Calibrator / Internal DMM – 6.5 Digit / Internal PC – 10.5" colour LCD/touch screen
    • Software: 7051 Calibrator/DMM Control software / EasyCal Calibration Software
    • Accessories: Printer and Connectivity kit / Premium Test Lead Set / User Manuals 


    7051 Plus Package - For Comprehensive Electrical and Process Calibration

    Includes all of the features & items listed above & selected options (*) shown below for maximum multi product calibration capabilities.

    Internal Options - Accuracies shown in the specifications tab


    High Voltage/Current option: AC/DC 1kV/22A (DMM calibration)


    Capacitance (1000pF - 100μF) / Inductance (1mH - 10H)


    Full Range Resistance (1Ω - 120MΩ) - including advanced PT100 Simulation


    Wideband AC Voltage (1MHz Max. 20mV - 20V)


    Oscilloscope Calibration (1mV - 200V, 0.1Hz - 100MHz)


    Oven-Controlled Frequency Reference (for timer/counters, increases accuracy to 0.1ppm from 0.1Hz to 10MHz). 9770 must be fitted

    9769 Scope 2.2GHz Levelled Sine Generator
    CC12A 7051 Control Centre Upgrade to CC12 PC with 12.1” touch screen
    External Options and Calibration Certificates


    Rubidium Frequency Reference (9770 Scope option must be fitted)  -  View data sheet


    Current Probe Calibration Adaptor (9770 Scope option must be fitted)  -  View data sheet


    Clamp Meter Adaptor (1 & 50 turn coil)  -  View data sheet


    Optical Tacho Adaptor  -  View data sheet

    TETRQ Torque Wrench Calibration Unit (module or benchtop with external transducers)
    7070 Dry Block Calibrator (-17 to 140°C)  -  View data sheet
    7071 Dry Block Calibrator (33 to 320°C)  -  View data sheet


    Dry Block Calibrator (33 to 650°C)  -  View data sheet


    Factory Calibration Certificate (NPL traceable)

    C134 UKAS Calibration Certificate (ISO 17025)
    EasyCal Software Accessories


    Bar Code Reader  -  View data sheet


    Cal and ID Label Printer  -  View data sheet


    Job and Address Label Printer  -  View data sheet

    EasyCal Additional Licenses, Add-ons, and Support Packages


    Additional EasyCal Full License 


    Additional EasyCal Work Station License: Allows Job Management, Cal Due Instrument Attachments / Cert History, Batch Instrument Edit and Procedure Wizards. Suitable for use in complete lab set-up.


    EasyAdmin - 2 Users: Security add-on that enables setting of user rights, access levels, and more.


    EasyAdmin - 5 Users: Security add-on that enables setting of user rights, access levels, and more.


    EasyAdmin - 10 Users: Security add-on that enables setting of user rights, access levels, and more.

    ESP1 EasyCal Support Package 1: 1 year email and telephone support. Minor upgrades.
    ESP2 EasyCal Support Package 2: 2 year email and telephone support. Minor upgrades.
    EOT1 EasyCal Online Training Session (Via Remote Desktop)
  • PDF Downloads
    File Name File Size Language

    7051 Data Sheet



    7051 Extended Specifications



    7051+ Extended Specifications 127kB EN

    7051 Brochure

    3MB (Low Resolution)


    7051 Brochure

    6.3MB (High Resolution)


    CalBench Brochure

    8.4MB (Low resolution)


    CalBench Brochure

    20MB (Higher resolution)