7151 Vernier and Micrometer Calibration Kit

7151 Vernier and Micrometer Calibration Kit
  • 7151
  • 7151 Kit in carry cases

Features

  • Calibrate calipers, micrometers
  • Calibrate verniers, depth gauges
  • 47 piece grade 1 block set
  • 200 mm block holder
  • Cylindrical jaws
  • 4 optical flats
  • Compact granite surface plate

7151 Images

  • The 7151 is a comprehensive kit for dimensional calibration applications including verniers, calipers, micrometers, and depth gauges. The kit contains a 47 piece grade 1 metric gauge block set, with each gauge made of hardened alloy steel with a high quality surface finish. The set is housed in a fitted wooden case. A compact surface plate (305 x 230 x 50 mm) is included for precision depth measurements.

    For internal measurements a 200 mm gauge block holder and two cylindrical jaws is provided. Additionally 4 optical flats are supplied, for examining the flatness and parallelism of the measuring faces on external micrometers. Also supplied are a pair of cotton gloves, oil, wipes and leather chamois.

    The kit is supplied in two compact carry cases for storage and transport. A UKAS (ISO 17025) calibration certificate is supplied for the gauge block set, optical flats and surface plate.

  • 7151 Included Items

    Gauge Block Set

    47 piece grade 1 block set comprising of:

    - 21 pcs - 1 mm to 1.19 mm x .01 mm, (plus 1.005 mm)

    - 8 pcs - 1.2 mm to 1.9 mm x .1 mm

    - 8 pcs - 2 mm to 9 mm x 1 mm

    - 10 pcs - 10 mm to 100 mm x 10 mm

    Holder and Jaws2 00 mm gauge block holder and cylindrical jaws
    Optical Flats 4 optical flats (0 to 25 mm, grade 1)
    Surface Plate Compact granite surface plate: Size 305 x 230 x 50 mm, with a flatness of ±0.002 mm.
    Accessories Cotton gloves, inhibiting oil, lint free wipes, leather chamois
    Carry Cases 2 carry cases (W 450 x H 100 x D 380 mm each)
    Certification Calibration certificate supplied for all measurement items
  • Model and Description

    7151

    Vernier and Micrometer Calibration Kit

  • PDF Downloads
    File Name File Size Language

    7151 Data Sheet

    550 kB

    EN

  • Request for Quotation

    7151 Vernier and Micrometer Calibration Kit

    1.20

Related Products

  • 5051+ Multifunction Calibration System

    • Combined calibrator/DMM/PC
    • 0 - 1050 V & 0 - 22 A (AC/DC)
    • Source up to 1 GΩ resistance
    • Thermocouple simulate/measure
    • PT100, C & L, scope calibration
    • Clamp meter calibration
    • EasyCal Software included
    View 5051+
  • 7198 Pressure Calibration Accessories Kit

    • Adaptors/fittings/connectors/hoses
    • Metric/BSP/parallel/NPT adaptors
    • Coupling connectors
    • Quick release & minimess hoses
    • 10" adjustable spanner included 
    • Suitable for use with pumps
    • Compact kit for labs & on-site work
    View 7198
  • Calibration Benches

    • Universal calibration systems
    • Electrical/pressure/process
    • Power supplies, DMMs & scopes
    • Multifunction calibrator modules
    • Ideal for on-site test facilities
    • Automatic or manual calibration
    • Complete lab design service
    View CalBench
  • EasyCal Calibration Software

    • Automate the calibration process
    • Control TE calibrators & DMMs
    • Automated planning & scheduling
    • For use with multiple devices
    • 1200+ cal procedures included
    • Management/admin features
    • Easily produce certificates & reports
    View EasyCal