A PHP Error was encountered

Severity: Notice

Message: Undefined index: HTMLTitle

Filename: modulearea-site/modulearea-search_by_function.php

Line Number: 22

A PHP Error was encountered

Severity: Notice

Message: Undefined index: HTMLDescription

Filename: modulearea-site/modulearea-search_by_function.php

Line Number: 23

A PHP Error was encountered

Severity: Notice

Message: Undefined index: HTMLKeywords

Filename: modulearea-site/modulearea-search_by_function.php

Line Number: 24

Search Products by Function: Voltage

1006 DC Millivolt Source

1006 DC Millivolt Source
  • 3 ranges up to 1V
  • 0.02% accuracy
  • 20mA output current
  • Short circuit/overload protection
  • Safety terminals
  • 100 hours typical battery life
  • Supplied with protective cover

1007 DC Millivolt Potentiometer & Calibrator

1007 DC Millivolt Potentiometer & Calibrator
  • 3 ranges up to 1V
  • 0.02% accuracy
  • 20mA output current
  • Short circuit/overload protection
  • LED null measuring facility
  • 100 hours typical battery life
  • Portable with protective cover

1010 DC Voltage Calibrator

1010 DC Voltage Calibrator
  • 0.01μV to 10V in 5 ranges
  • 0.02% accuracy
  • Battery or mains operation
  • 30mA output current
  • 10ppm/hr stability
  • Battery level indicator
  • Safety terminals

1017 Voltage/Current/Resistance Calibrator

1017 Voltage/Current/Resistance Calibrator
  • DC Volts 10nV to 100V
  • DC Current 100nA to 100mA
  • Resistance 10mΩ to 10kΩ
  • 0.005% (50ppm) accuracy
  • 1 ppm setting resolution
  • Noise <2ppm (0.1 to 1Hz)
  • Stability <5ppm/day, <25ppm/yr

1030 Voltage and Current Source

1030 Voltage and Current Source
  • 10mV, 100mV, 1V ranges
  • 10mA, 100mA ranges
  • 0.1% accuracy
  • 0 to 8V available
  • Precision 10-turn dial
  • Battery level indicator
  • Battery powered 9V PP3

1044 Voltage and Current Calibrator

1044 Voltage and Current Calibrator
  • Measure voltage and current
  • Source voltage and current
  • 0.05% accuracy
  • 0 to 20V in 3 ranges
  • 0 to 20mA in 3 ranges
  • Battery power 9V PP3
  • Portable with carry case

1048 Voltage/Current/Loop Calibrator

1048 Voltage/Current/Loop Calibrator
  • Source/measure current & voltage
  • 3 Source ranges to 22mA or 22V
  • 3 Measure ranges to 70mA or 50V
  • Transmitter simulator/sink
  • Output steps and ramps
  • Fine adjustment (inching)
  • Accuracy 0.02% of span

1077 Milliamp Transducer Simulator

1077 Milliamp Transducer Simulator
  • 3 operating modes
  • 100mA source and load
  • 24V line mode
  • 0.02% accuracy
  • Safety terminals
  • Battery level indicator
  • Supplied with protective cover

5018 Programmable DC/AC V/I Calibrator

5018 Programmable DC/AC V/I Calibrator
  • 0 - 22V DCV (30V DC optional)
  • 0 - 22V AC, 220V & 1kV DC options
  • Optional 0 - 220mA AC/DC
  • Ramping feature
  • GPIB / RS-232 / USB interfaces
  • Ideal for ATE applications
  • EasyCal Software compatible

5025 Multifunction Calibrator

5025 Multifunction Calibrator
  • 0 - 1050V & 0 - 22A (AC/DC)
  • 1Ω to 1GΩ resistance
  • Thermocouple simulation
  • Oscilloscope calibration option
  • PT100, C & L, and power options
  • Clamp meter calibration
  • EasyCal software compatible

5025E Multifunction Calibrator

5025E Multifunction Calibrator
  • 0 - 1050V & 0 - 22A (AC/DC)
  • 10Ω to 1GΩ resistance
  • Thermocouple & PT100 simulation
  • Digital frequency
  • Optional clamp meter calibration
  • Scope and power options
  • EasyCal software compatible

5030 Electrical Tester Calibrator

5030 Electrical Tester Calibrator
  • RCD: 3 - 2500mA, 10 - 2000ms
  • Loop 50mΩ to 1.8kΩ
  • Insulation up to 2GΩ / 1kV
  • Continuity 0.1Ω to 10kΩ
  • RS-232 / USB Control
  • Fast and intuitive user interface
  • EasyCal software compatible

5033 3 Channel DC Power Source

5033 3 Channel DC Power Source
  • 3 independent channels
  • 0 to 20V DC 2A drive capability
  • 40 watts max per channel
  • 10μV resolution setting
  • Programmable via GPIB interface
  • Easy to use command language
  • 4 Terminal Output

5051Plus Multifunction Calibration System

5051Plus Multifunction Calibration System
  • Combined calibrator/DMM/PC
  • 0 - 1050V & 0 - 22A (AC/DC)
  • Source up to 1GΩ resistance
  • Thermocouple simulate/measure
  • PT100, C & L, scope calibration
  • Clamp meter calibration
  • EasyCal Software included

5065 6.5 digit Multimeter

5065 6.5 digit Multimeter
  • Resolution 6 1/2 digits
  • Accuracy: 0.005% DC voltage
  • USB interface
  • Optional GPIB interface
  • Temperature measurements
  • 10 channel scanner option
  • EasyCal software compatible

5075 7.5 digit Multimeter

5075 7.5 digit Multimeter
  • 7½ digit resolution
  • AC/DC voltage & current
  • Resistance & temperature
  • Capacitance & frequency
  • 18ppm/year accuracy
  • 10 channel scanner option
  • EasyCal software compatible

5077 Power Calibrator

5077 Power Calibrator
  • 20mA to 22A AC/DC
  • 100A AC I transformer option
  • 1mV to 1050V AC/DC
  • +90.0 deg to -90.0 deg
  • 0.00 to 1.00 Lead/Lag
  • 45 to 400 Hz in 0.1Hz steps
  • RS-232 / GPIB / USB interface

7005 Voltage/Current/Loop Calibrator

7005 Voltage/Current/Loop Calibrator
  • Loop source/measure - V or I
  • Measure 0 - 25V or 0 - 125mA
  • Source 0 - 21V or 0 - 50mA
  • Accuracy 0.01%
  • Resolution 1μA or 1mV
  • Programmable ranges
  • Manual step, auto-step & ramp