5077 Power Calibrator

5077 Power Calibrator

Features

  • 20mA to 22A AC/DC
  • 100A AC I transformer option
  • 1mV to 1050V AC/DC
  • +90.0 deg to -90.0 deg
  • 0.00 to 1.00 Lead/Lag
  • 45 to 400 Hz in 0.1Hz steps
  • RS-232 / GPIB / USB interface
 

A high accuracy AC and DC power calibrator suitable for calibrating watt-meters, power meters, and kW-Hr meters. Supplied with its own “PC Virtual Control” software allowing the user full control via laptop or PC. Frequency can be set in 0.1Hz steps from 45 to 400Hz, and phase in 0.1degree steps. Alternatively power factor (PF) can be set in 0.01 steps. The output can be displayed as VA or Watts.

The standard maximum AC current output (22A) can be extended to 100A by using an optional 100A current transformer. This extends the maximum power to 0.1MW/MVA. A clamp meter adaptor option is also available (1 and 50 turns).

EasyCal - Manage, Automate and Optimise the Calibration Process
The 5077 can also be controlled using Time Electronics’ EasyCal software. This provides increased speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001,ISO 17025, and other international quality standards.

Technical Specifications

DC Voltage
Range Accuracy 1 year Output Resistance Max Output Current Resolution
*2V 0.01% + 500μV < 0.5Ω 20mA 1μV
*20V 0.01% + 500μV < 0.5Ω 20mA 10μV
300V 0.02% + 30mV < 5Ω 20mA 100μV
1050kV 0.05% + 50mV < 10Ω 10mA 1mV

*Accuracy is specified at minimum current output.

DC Current
Range Accuracy 1 year Compliance Voltage Resolution
2A 0.03% + 500μA 5V 100μA
22A 0.05% + 6mA 4V 1mA
AC Voltage (45Hz to 400Hz 0.02% accuracy)
Range Accuracy 1 year Output Resistance Max Output Current Resolution
*2V 0.03% + 500μV < 0.5Ω 20mA 100μV
*20V 0.03% + 2mV < 1Ω 20mA 1mV
**300V 0.06% + 30mV < 5Ω 20mA 10mV
**1050kV 0.08% + 90mV < 10Ω 10mA 100mV

*Accuracy is specified at minimum current output.
**Accuracy is specified at 100Hz for current outputs less than 5A.

AC Current (45Hz to 400Hz 0.02% Accuracy)
Range Accuracy 1 year Compliance Voltage Resolution
2A 0.1% + 2mA 3.5V 100μA
22A 0.1% + 20mA 3V 1mA
Phase Angle (Applies to outputs above 22 Volts)
Frequency Range Accuracy 1 year Resolution
45 to 99Hz -90.0 to +90.0 deg 0.3 deg 0.1 deg
100Hz to 400Hz -90.0 to +90.0 deg 1 deg 0.1 deg
Power Factor
Frequency Range Resolution
45 to 400Hz 0.00 to 1.00 0.01

The accuracy of the power is complex and is determined by using a formula, which combines the errors due to Voltage, Current, and Phase.
Power Accuracy (%) = SqrRt (Voltage accuracy2 + Current accuracy2 + Phase Correction2)
Where Phase Correction (%) = 100x(1-Cos(Phase+PhaseAcc)/Cos Phase)


General Specifications

Warm up 1 Hour to full accuracy
Settling Time Less than 5 seconds

Standard Interfaces

GPIB (IEEE-488), RS-232, USB

Temp Performance Operating: 0 to 40°C, Full Spec: 23°C +/- 5°C, Storage: -10°C to 50°C
Operating Humidity < 80% non-condensing
Operating Altitude 0 to 3km. Non operating: 3km to 12km
Line Power 100 - 230V AC 50/60Hz. Power Consumption 60W typical, 80W Max.

Dimensions

W440 x H198 x D580mm (17.6 x 7.8 x 32.8”)

Weight 25kg (36lbs)
Country of Origin UK

Supplied With

Virtual control software, user manual, RS-232 cable, and USB adaptor/cable

Models

5077

Power Calibrator

Options

9790

100 Amp AC Current Transformer - View Data Sheet

9780

Clamp Meter Adaptor - View Data Sheet

9735 Test Lead Set
C160 Factory Calibration Certificate (NPL traceable)
C124 UKAS Calibration Certificate (ISO 17025)
Calibration Software and Accessories

ECFLA

EasyCal Full License - when purchased with multifunction calibrator/DMM: Discounted full license with 1 year support.
For further licenses and EasyCal add-ons see the Easycal web page or PDF brochure

9795 Printer & Connectivity Kit (Printer, DVD-RW, 4 Port USB Hub, Numeric Key Pad & USB Memory Stick)
9777 Bar Code Reader
9778 Cal and ID Label Printer
9779 Job and Address Label Printer
9597 GPIB Cable
9743 PCI - GPIB interface card

9794

GPIB - USB Adaptor

ESP1

EasyCal Support Package 1: 1 year email and telephone support. Minor upgrades. 

ESP2 EasyCal Support Package 2: 2 year email and telephone support. Minor upgrades.
EOT1 EasyCal Online Training Session (Via Remote Desktop)
PDF Downloads
File Name File Size Language

5077 Data Sheet

510kB

EN

9790 AC Current Transformer Data Sheet

250kB

EN

9780 Clamp Meter Adaptor Data Sheet

165kB

EN

EasyCal Brochure

3MB (low resolution)

EN

EasyCal Brochure

7MB (Higher resolution)

EN