Home |
Products |
Search products by function |
Voltage
Search Products by Function: Voltage
1006 DC Millivolt Source
- 3 ranges up to 1V
- 0.02% accuracy
- 20mA output current
- Short circuit/overload protection
- Safety terminals
- 100 hours typical battery life
- Supplied with protective cover
1007 DC Millivolt Potentiometer & Calibrator
- 3 ranges up to 1V
- 0.02% accuracy
- 20mA output current
- Short circuit/overload protection
- LED null measuring facility
- 100 hours typical battery life
- Portable with protective cover
1010 DC Voltage Calibrator
- 0.01μV to 10V in 5 ranges
- 0.02% accuracy
- Battery or mains operation
- 30mA output current
- 10ppm/hr stability
- Battery level indicator
- Safety terminals
1017 Voltage/Current/Resistance Calibrator
- DC Volts 10nV to 100V
- DC Current 100nA to 100mA
- Resistance 10mΩ to 10kΩ
- 0.005% (50ppm) accuracy
- 1 ppm setting resolution
- Noise <2ppm (0.1 to 1Hz)
- Stability <5ppm/day, <25ppm/yr
1030 Voltage and Current Source
- 10mV, 100mV, 1V ranges
- 10mA, 100mA ranges
- 0.1% accuracy
- 0 to 8V available
- Precision 10-turn dial
- Battery level indicator
- Battery powered 9V PP3
1044 Voltage and Current Calibrator
- Measure voltage and current
- Source voltage and current
- 0.05% accuracy
- 0 to 20V in 3 ranges
- 0 to 20mA in 3 ranges
- Battery power 9V PP3
- Portable with carry case
1048 Voltage/Current/Loop Calibrator
- Source/measure current & voltage
- 3 Source ranges to 22mA or 22V
- 3 Measure ranges to 70mA or 50V
- Transmitter simulator/sink
- Output steps and ramps
- Fine adjustment (inching)
- Accuracy 0.02% of span
1077 Milliamp Transducer Simulator
- 3 operating modes
- 100mA source and load
- 24V line mode
- 0.02% accuracy
- Safety terminals
- Battery level indicator
- Supplied with protective cover
5018 Programmable DC/AC V/I Calibrator
- 0 - 22V DCV (30V DC optional)
- 0 - 22V AC, 220V & 1kV DC options
- Optional 0 - 220mA AC/DC
- Ramping feature
- GPIB / RS-232 / USB interfaces
- Ideal for ATE applications
- EasyCal Software compatible
5025 Multifunction Calibrator
- 0 - 1050V & 0 - 22A (AC/DC)
- 1Ω to 1GΩ resistance
- Thermocouple simulation
- Oscilloscope calibration option
- PT100, C & L, and power options
- Clamp meter calibration
- EasyCal software compatible
5025E Multifunction Calibrator
- 0 - 1050V & 0 - 22A (AC/DC)
- 10Ω to 1GΩ resistance
- Thermocouple & PT100 simulation
- Digital frequency
- Optional clamp meter calibration
- Scope and power options
- EasyCal software compatible
5030 Electrical Tester Calibrator
- RCD: 3 - 2500mA, 10 - 2000ms
- Loop 50mΩ to 1.8kΩ
- Insulation up to 2GΩ / 1kV
- Continuity 0.1Ω to 10kΩ
- RS-232 / USB Control
- Fast and intuitive user interface
- EasyCal software compatible
5033 3 Channel DC Power Source
- 3 independent channels
- 0 to 20V DC 2A drive capability
- 40 watts max per channel
- 10μV resolution setting
- Programmable via GPIB interface
- Easy to use command language
- 4 Terminal Output
5051Plus Multifunction Calibration System
- Combined calibrator/DMM/PC
- 0 - 1050V & 0 - 22A (AC/DC)
- Source up to 1GΩ resistance
- Thermocouple simulate/measure
- PT100, C & L, scope calibration
- Clamp meter calibration
- EasyCal Software included
5065 6.5 digit Multimeter
- Resolution 6 1/2 digits
- Accuracy: 0.005% DC voltage
- USB interface
- Optional GPIB interface
- Temperature measurements
- 10 channel scanner option
- EasyCal software compatible
5075 7.5 digit Multimeter
- 7½ digit resolution
- AC/DC voltage & current
- Resistance & temperature
- Capacitance & frequency
- 18ppm/year accuracy
- 10 channel scanner option
- EasyCal software compatible
5077 Power Calibrator
- 20mA to 22A AC/DC
- 100A AC I transformer option
- 1mV to 1050V AC/DC
- +90.0 deg to -90.0 deg
- 0.00 to 1.00 Lead/Lag
- 45 to 400 Hz in 0.1Hz steps
- RS-232 / GPIB / USB interface
7005 Voltage/Current/Loop Calibrator
- Loop source/measure - V or I
- Measure 0 - 25V or 0 - 125mA
- Source 0 - 21V or 0 - 50mA
- Accuracy 0.01%
- Resolution 1μA or 1mV
- Programmable ranges
- Manual step, auto-step & ramp