5080 PAT Calibrator

5080 PAT Calibrator

Features

  • Calibrate PATs & VDE0701 testers
  • Battery powered
  • LCD display of voltage & current
  • Safety interlock feature
  • Earth bond currents up to 50A AC
  • Load test currents up to 13A AC
  • Impact resistant case
 

A precision calibrator designed to provide rapid high accuracy calibration of portable appliance testers and insulation/continuity testers.
The 5080 has calibration functions for earth bond, insulation, leakage, touch leakage, and load test.  

Housed in a robust safety case the 5080 is easily portable and ideal for field calibration work. It is battery powered, which ensures isolation and prevents inaccuracies due to stray leakage. Features include safety interlock that prevents contact with earth bond studs during insulation and leakage tests, and an LCD display for voltage and current.

Technical Specifications

Earth Bond: Calibrated low value resistive loads

Values / Accuracy

20mΩ, accuracy 5%
190mΩ, 210mΩ, 950mΩ, 1.050mΩ, 1.08Ω, 2Ω, 10Ω, 18Ω, accuracy 1%

Open circuit voltage measurement

Range: 0 to 20V
Accuracy: 0.25% of full scale

High current AC measurement

Range: 0 to 50A AC
Accuracy: 0.5% of reading +/- 0.2A

Low current AC measurement

Range: 0 to 2A AC
Accuracy: 0.5% of reading +/- 2mA

Low current DC measurement

Range: 0 to 2A DC
Accuracy: 1% of reading +/- 2mA

Insulation: Calibrated high value resistive loads

Values / Accuracy

95kΩ, 105kΩ, 500kΩ, 950kΩ, 1.05MΩ, 5MΩ, 10MΩ, accuracy 0.1%
20MΩ, 50MΩ, 100MΩ, accuracy 1.0%

Open circuit voltage measurement

Range: 0 to 1kV DC
Accuracy: 0.25% of full scale

Current measurement Range: 0 to 20mA DC. Accuracy: 0.25% of full scale
Leakage: Resistive loads for leakage current
Nominal Leakage Currents At 230V AC of 0.5, 1, 2, 5, 10, 15mA

Mains voltage measurement

Range: 0 to 500V AC
Accuracy 0.25% of full scale

Leakage current measurement

Range: 0 to 20mA AC
Accuracy 0.25% of full scale

Touch Leakage: Constant current source for touch leakage meters
Current 1.9mA AC 50 +/-5 Hz, into 2K2 maximum load resistance
Current measurement Range: 0 to 2mA AC. Accuracy: 0.25% of full scale
Load Test: Connection of external load via an IEC connector

Mains voltage measurement

Range: 0 to 500V AC
Accuracy: 0.25% of full scale

Load current measurement

Range: 0 to 13A AC
Accuracy: 0.5% of full scale


General Specifications

Power Internal battery 6V re-chargeable NiCad, >200 hrs between charges.
Dimensions W406 x H175 x D330mm
Weight 5.5kg
Supplied With 4mm terminal box adaptor, 110V adaptor, IEC connector (for external load), battery charger, and user manual.
Optional Extras Calibration certificates traceable NPL and UKAS
Country of Origin UK
Models

5080

PATCAL – Portable Appliance Tester Calibrator

Options
C188 Factory Calibration Certificate (NPL traceable)
C135 UKAS Calibration Certificate (ISO 17025)
PDF Downloads
File Name File Size Language

5080 Data Sheet

225kB

EN