1067 - 6 Decade Precision Resistance Box

1067 - 6 Decade Precision Resistance Box

Features

  • 10mΩ to 12kΩ
  • 0.01% accuracy
  • Precision PT100 simulation
  • 6 digit resolution
  • Better than 20ppm/year stability
  • Residual resistance < 10mΩ
  • Fully screened
 

A precision resistance decade box suitable for a wide range of simulation work. High accuracy, long term stability, and low temperature coefficient make the 1067 ideal for simulating and calibrating precision PT100 sensors and temperature indicators/meters that use resistive sensors.

Special care has been taken in the construction of the 1067 to ensure that the residual end resistance is as low and as stable as possible.
Multiple self-cleaning silver alloy contacts are used for each position to ensure outstanding performance and long life. 

Housed in a robust metal case the 1067 is fully screened and low thermal emf terminals are used. The slim line design means it takes up minimum bench space and is easily transportable.

Resistance is selected by dialling the value required using the rotary switches. This enables precise setting with a clear unambiguous indication.
Each decade is scaled from 0 to 11 and therefore allows convenient overlap of the set values. The maximum value settable is 12,222.21 ohms.

Technical Specifications

Range

0 to 12kΩ

Resolution

10mΩ steps

Number of Decades

6, each decade settable from 0 to 11

Accuracy

± 0.01% of setting ± 2mΩ, after deduction of residual end resistance ±1mΩ for residual variation. At calibration temperature of 22°C.

Residual Resistance

Less than 10mΩ. Less than 1mΩ variation

Power Rating

0.35 watt per resistor

Voltage Rating

Maximum 200V DC/AC RMS

Stability

20ppm/year (>1Ω), 100ppm/year (<1Ω)

Current Rating

10mΩ range: 3A, 100mΩ range: 2A, 1Ω range: 600mA, 10Ω range: 200mA, 100Ω range: 60mA, 1kΩ range: 20mA

Insulation

Case to resistance terminals 2kV / 50Hz maximum

Temperature Coefficient

Less than 10ppm/°C (> 1Ω). Less than 20ppm/°C (< 1Ω)

Operating Torque

Less than 0.1Nm

Contacts

Make before break – silver alloy


General Specifications

Dimensions

W355 x H63 x D89mm

Weight

1.1kg

Optional Extras

Calibration certificates traceable to NPL and UKAS

Country of Origin UK
Models

1067

Precision Resistance Decade Box

Options

C161

Factory Calibration Certificate (NPL traceable)

C114 UKAS Calibration Certificate (ISO 17025)
PDF Downloads
File Name File Size Language

1067 Data Sheet

210kB

EN

1067 User Manual

177kB

EN