Home |
Products |
Search products by function |
Resistance
Search Products by Function: Resistance
1017 Voltage/Current/Resistance Calibrator
- DC Volts 10nV to 100V
- DC Current 100nA to 100mA
- Resistance 10mΩ to 10kΩ
- 0.005% (50ppm) accuracy
- 1 ppm setting resolution
- Noise <2ppm (0.1 to 1Hz)
- Stability <5ppm/day, <25ppm/yr
1040 - 8 Decade Resistance Box
- 1Ω to 100MΩ
- High accuracy
- Clear visual indication
- High stability
- Safety terminals
- Low temperature coefficient
- Supplied with protective cover
1041 - 5 Decade Resistance Box
- 0.01Ω to 1kΩ
- 10mΩ resolution
- Ideal for PRT/RTD
- High stability
- Safety terminals
- Low temperature coefficient
- Supplied with protective cover
1049 PT100 Simulator
- -200°C to + 800°C
- ± 0.3°C accuracy
- Based on ITS 90 EN60751
- 23 set points
- Exceeds class A
- Good temperature stability
- Passive resistance source
1050 PT100 Simulator
- -100°F to + 1000°F
- ± 0.5°F accuracy
- Based on ITS 90 EN60751
- 23 set points
- Exceeds class A
- Good temperature stability
- Passive resistance source
1051 - 8 Decade Resistance Box
- 0.01Ω to 1MΩ
- High accuracy & stability
- Clear visual indication
- Safety terminals
- Low temperature coefficient
- Suitable for PRT/RTD
- Supplied with protective cover
1061 - 6 Decade Resistance Box
- 1Ω to 1.2MΩ
- In-line readout
- Stable metal film resistors
- Mechanically/electrically robust
- Safety terminals
- Fully screened
1065 - 6 Decade Power Resistance Box
- 0.1Ω to 120kΩ
- 1% accuracy
- 10W per resistor dissipation
- Residual resistance < 20mΩ
- In-line readout
- Mechanically/electrically robust
- Fully screened
1067 - 6 Decade Precision Resistance Box
- 10mΩ to 12kΩ
- 0.01% accuracy
- Precision PT100 simulation
- 6 digit resolution
- Better than 20ppm/year stability
- Residual resistance < 10mΩ
- Fully screened
1068 - 5 Fixed Resistance Box
- 5 fixed resistance ranges
- High accuracy
- Clear visual indication
- Portable and compact
- Simple operation
- Robust casing
- Ideal for education
5011 Resistance / Temperature Calibrator
- 1Ω to 120MΩ
- RTD & thermocouple simulation
- DCV and DCI options
- 10MHz frequency option
- RS-232 / GPIB / USB interfaces
- Front panel operation
- EasyCal Software compatible
5025 Multifunction Calibrator
- 0 - 1050V & 0 - 22A (AC/DC)
- 1Ω to 1GΩ resistance
- Thermocouple simulation
- Oscilloscope calibration option
- PT100, C & L, and power options
- Clamp meter calibration
- EasyCal software compatible
5025E Multifunction Calibrator
- 0 - 1050V & 0 - 22A (AC/DC)
- 10Ω to 1GΩ resistance
- Thermocouple & PT100 simulation
- Digital frequency
- Optional clamp meter calibration
- Scope and power options
- EasyCal software compatible
5030 Electrical Tester Calibrator
- RCD: 3 - 2500mA, 10 - 2000ms
- Loop 50mΩ to 1.8kΩ
- Insulation up to 2GΩ / 1kV
- Continuity 0.1Ω to 10kΩ
- RS-232 / USB Control
- Fast and intuitive user interface
- EasyCal software compatible
5051Plus Multifunction Calibration System
- Combined calibrator/DMM/PC
- 0 - 1050V & 0 - 22A (AC/DC)
- Source up to 1GΩ resistance
- Thermocouple simulate/measure
- PT100, C & L, scope calibration
- Clamp meter calibration
- EasyCal Software included
5065 6.5 digit Multimeter
- Resolution 6 1/2 digits
- Accuracy: 0.005% DC voltage
- USB interface
- Optional GPIB interface
- Temperature measurements
- 10 channel scanner option
- EasyCal software compatible
5068 Insulation Tester Calibrator
- 100KΩ to 10GΩ
- Basic accuracy 1%
- Up to 2.5kV operation
- Battery operation
- Fully shrouded safety connectors
- Display of open circuit voltage
- Display of short circuit current
5069 Insulation Tester Calibrator
- 100KΩ to 100GΩ
- Basic accuracy 1%
- Up to 10kV operation
- Battery operation
- Fully shrouded safety connectors
- Display of open circuit voltage
- Display of short circuit current
5070 Micro-ohm Meter Calibrator
- Calibrate ductor testers
- Calibrate micro-ohm meters
- 0.2, 2, 20, 200, 2000mΩ
- 5 cal points: 0/25/50/75/100%
- Gold plated terminals
- Low thermal emf connection
- Portable robust carrying case
5075 7.5 digit Multimeter
- 7½ digit resolution
- AC/DC voltage & current
- Resistance & temperature
- Capacitance & frequency
- 18ppm/year accuracy
- 10 channel scanner option
- EasyCal software compatible
5080 PAT Calibrator
- Calibrate PATs & VDE0701 testers
- Battery powered
- LCD display of voltage & current
- Safety interlock feature
- Earth bond currents up to 50A AC
- Load test currents up to 13A AC
- Impact resistant case