1048 Voltage/Current/Loop Calibrator
- Source/measure current & voltage
- 3 Source ranges to 22mA or 22V
- 3 Measure ranges to 70mA or 50V
- Transmitter simulator/sink
- Output steps and ramps
- Fine adjustment (inching)
- Accuracy 0.02% of span
1077 Milliamp Transducer Simulator
- 3 operating modes
- 100mA source and load
- 24V line mode
- 0.02% accuracy
- Safety terminals
- Battery level indicator
- Supplied with protective cover
1090 Portable Process Calibrator
- Measure/simulate thermocouples
- Measure/simulate PT100
- Measure/source (µV/mV/mA)
- Display in °C and °F
- Automatic CJC - selectable
- 10 point memory recall
- Process loops 4-20mA/0-50mA
5025 Multifunction Calibrator
- 0 - 1050V & 0 - 22A (AC/DC)
- 1Ω to 1GΩ resistance
- Thermocouple simulation
- Oscilloscope calibration option
- PT100, C & L, and power options
- Clamp meter calibration
- EasyCal software compatible
5025E Multifunction Calibrator
- 0 - 1050V & 0 - 22A (AC/DC)
- 10Ω to 1GΩ resistance
- Thermocouple & PT100 simulation
- Digital frequency
- Optional clamp meter calibration
- Scope and power options
- EasyCal software compatible
5030 Electrical Tester Calibrator
- RCD: 3 - 2500mA, 10 - 2000ms
- Loop 50mΩ to 1.8kΩ
- Insulation up to 2GΩ / 1kV
- Continuity 0.1Ω to 10kΩ
- RS-232 / USB Control
- Fast and intuitive user interface
- EasyCal software compatible
5051Plus Multifunction Calibration System
- Combined calibrator/DMM/PC
- 0 - 1050V & 0 - 22A (AC/DC)
- Source up to 1GΩ resistance
- Thermocouple simulate/measure
- PT100, C & L, scope calibration
- Clamp meter calibration
- EasyCal Software included
7005 Voltage/Current/Loop Calibrator
- Loop source/measure - V or I
- Measure 0 - 25V or 0 - 125mA
- Source 0 - 21V or 0 - 50mA
- Accuracy 0.01%
- Resolution 1μA or 1mV
- Programmable ranges
- Manual step, auto-step & ramp
7006 Loop Simulator & Source
- 4 - 20mA or 0 - 10V loops
- 7 calibration set-points
- Accuracy 0.1%
- TxSim and RxTest modes
- Autostep output - adjustable rate
- Battery powered PP3
- Internal loop drive supply
7007 Loop Signal Indicator
- 4 - 20mA, 0 -10V, 0 - 50V ranges
- LCD 4 digit display, mA, V, % of rng
- Accuracy 0.05%
- RxSim, TxTest, or 50mA/50V modes
- Internal loop supply, 25mA max
- Battery powered 9V PP3
- Supplied with carry case
7093 Precision Loop and Dual Pressure Calibrator
- Vacuum to 600bar versions
- Pressure accuracy 0.04% of FS
- 0.025% high accuracy versions
- Pneumatic or hydraulic
- I measure: 125mA, Source: 50mA
- V measure: 25V, Source: 21V
- V/I accuracy 0.01%