1030 Voltage and Current Source

1030 Voltage and Current Source

Features

  • 10mV, 100mV, 1V ranges
  • 10mA, 100mA ranges
  • 0.1% accuracy
  • 0 to 8V available
  • Precision 10-turn dial
  • Battery level indicator
  • Battery powered 9V PP3
 

The 1030 MicroCal is a portable voltage and current calibrator for general purpose signal injection. It is suitable for voltage and current loop signal simulation as well as thermocouple simulation. 

Being both cost-effective and simple operation make the 1030 a popular instrument that is used in various applications across industries. The compact (115 x 62 x 55mm) and durable design makes it ideal for use in both the lab and field, with carry case supplied as standard. Typical battery life is 60 hours. An optional rechargeable battery pack is available, with mains charger that connects via a socket on the top of the unit. 

The MicroCal is designed for traditional analogue control. The precision 10-turn dial provides a conventional feel to selecting the required output with a setting resolution of 1 part in a 1000 (0.1%).

Three voltage ranges give an adjustable output from 10µV to 1V and two current ranges for 10µA to 100mA. An additional 0 to 8V output can be obtained by using a precision 1KΩ resistor that is supplied with the unit. The resistor is connected across the output terminals and the 10mA current range selected.  This allows the output to be set between 0 and +/- 8V with a 10mV resolution and an accuracy of  0.3% of full scale.

The 1030 is simple to operate and does not require any standardisation prior to use.  The operator needs only to switch on, check the battery condition, and set the required range and output value.

Applications
Accurate measurements of low ohm values, such as platinum resistance thermometers, can be performed by using the 1030 as a current source and measuring the voltage across the load with a digital voltmeter. The 10mV range is ideal for simulation of all types of thermocouple.

The 1030 is a compact calibration tool, ideal for electrical engineers to test various measurement equipment, temperature controllers, and PLC analog input cards, with mV or mA inputs. As part of the Time Electronics handheld calibrator range it is designed for accuracy and reliability, whilst maintaining ease of use.

Technical Specifications

Voltage
Range Accuracy Resolution Max Output Current Output Resistance
0 to 10mV 0.2% of full scale 10μV Limited by o/p resistance 10Ω
0 to 100mV 0.1% of full scale 100μV 20mA 0.2Ω
0 to 1V 0.1% of full scale 1mV 20mA 0.2Ω

0 to 8V (using supplied 1kΩ resistor)

0.3% of full scale

10mV

Limited by o/p resistance

1kΩ

Current
Range Accuracy Resolution Max Output Voltage
0 to 10mA 0.2% of full scale 10μA 8V
0 to 100mA 0.2% of full scale 100μA 8V
Linearity 0.15%
Temperature Coefficient 150ppm of full scale per °C (Outside 18°C to 28°C )
Noise 30ppm of full scale

Battery

PP3 size, 9V. Approximately 60 hours life. An optional alternative power source is a NiMH rechargeable cell of the same type. This can be recharged via the socket on the top of the unit without removing the cell from the unit.

Battery Condition Monitored by front panel indicator
Output Polarity Positive or negative, switch selected. A centre ‘off ‘ position is also provided.
Maximum Overload The 1030 can withstand continuous open circuit or short circuit on all ranges.


General Specifications

Dimensions

H115 x W62 x D55mm

Weight

0.24kg

Supplied With

Leatherette carry case, 1kΩ resistor, 9V PP3 battery (installed), and user manual.

Optional Extras

Rechargeable battery packs (240V or 110V mains). 
Calibration certificates traceable to NPL and UKAS.

Country of Origin UK
Models

1030

MicroCal - Voltage and Current Source

Options

1031

Rechargeable Battery Pack (NiMH Battery and 240V Mains Charger)

1032

Rechargeable Battery Pack (NiMH Battery and 110V Mains Charger)

C155

Factory (NPL Traceable) Calibration Certificate

C110 UKAS Calibration Certificate (ISO 17025)
PDF Downloads
File Name File Size Language

1030 Data Sheet

186kB

EN

1030 User Manual

338kB

EN