1024 DC Current Calibrator

1024 DC Current Calibrator

Features

  • 0 to 100mA output in 5 ranges
  • 0.02% accuracy
  • 10ppm/hr stability
  • Up to 15V output drive
  • Null measuring facility
  • Safety terminals
  • Battery or mains operation
 

A precision DC current source for calibration and test applications from nanoamp levels to 100mA. 

The 1024 is a solid state battery powered instrument which is easily portable and convenient for laboratory, field, or industrial use. It incorporates many of the well-proven circuit techniques of the Time Electronics Type 1010 DC Voltage Calibrator.

The null balance system enables the 1024 to be used for making accurate current measurement in addition to its basic function as a calibrator. Operation is by backing the current source output against the current to be measured, with the difference being displayed on a sensitive centre zone null meter. At the null point, there is no voltage drop across the 1024.

The 1024 employs a precision aged reference diode as a basic reference source. Excellent zero stability is ensured by the use of a high performance FET chopper amplifier system. Precision metal film resistors with temperature coefficients of less than 10ppm per °C are used to maintain the accuracy and stability of the initial calibration.

The 1024 can be powered from mains supply or by the internal rechargeable battery pack. When the calibrator is plugged into the mains supply the internal batteries will automatically start to recharge. If unplugged from the mains during operation the internal batteries will continue to power the instrument. Full charge allows 12 hours typical use. The battery condition monitored by a meter on the front panel.

Safety Terminals
Fitted as standard and fully compatible with 4mm shrouded plugs, as well as standard plugs, bare wires, and spade terminals.

Applications
Applications include calibration and testing of current sensitive transducers; calibration and linearity tests on digital and electronic current meters; and semiconductor parameter measurements, for example diode conduction voltages at specified current levels. 

The 1024 is a precision test instrument ideal for current calibration and measurement applications. As part of the Time Electronics portable test equipment range it is robust, high accuracy, and simple operation.

Technical Specifications

Output

0 to 100mA in 5 ranges:
0 to 99.999mA in 1μA steps
0 to 9.9999mA in 100nA steps
0 to 999.99μA in 10nA steps
0 to 99.999μA in 1nA steps
0 to 9.9999μA in 0.1nA steps

Accuracy

± 0.02% of setting + ± 0.005% of range + ± 0.2nA

Voltage Capacity

15V with new batteries or mains power (11V with minimum allowable battery volts).

Regulation

Load: better than 5ppm per volt. Supply: better than 5ppm per volt.

Output Polarity

Positive or negative switch selected. A centre ‘off’ position provides an open circuit on the output terminals.

Out of Limit Warning

A front panel LED indicator provides warning of insufficient drive voltage.

Output Stability

Less than 30ppm per °C (0°C to + 50°C).
Less than 10ppm per hour at constant temperature.
Less than 75ppm per 6 months.

Output Noise

100mA, 10mA and 1mA ranges: less than 5ppm of full scale.
100μA and 10μA ranges: less than 10ppm of full scale ± 0.1nA.

Null Sensitivity

Adjustable from ± 25mA to ± 25μA FSD via front panel control. Maximum resolution is 0.5μA.

Power Supply

Time Electronics power unit type PU2 which is housed in the rear of the 1024. The PU2 will power the 1024 direct from the mains or an internal rechargeable battery. The battery is automatically charged when mains power is connected. Access to the power supply is from the back of instrument.

Battery Level Indicator A front panel display provides a continuous indication of the battery state.


General Specifications

Dimensions

W217 x H160 x D193mm

Weight

3.3kg

Optional Extras

Leather carry case. Calibration certificates traceable to NPL and UKAS

Country of Origin UK
Models

1024

DC Current Calibrator with null measuring facility

Options

9021

Carry Case

C154

Factory (NPL Traceable) Calibration Certificate

C106

UKAS Calibration Certificate (ISO 17025)

PDF Downloads
File Name File Size Language

1024 Data Sheet

205kB

EN

1024 User Manual

225kB

EN