Portable Voltage & Current Instruments

1044 Voltage and Current Calibrator

  • Measure voltage and current
  • Source voltage and current
  • 0.05% accuracy
  • 0 to 20V in 3 ranges
  • 0 to 20mA in 3 ranges
  • Battery power 9V PP3
  • Portable with carry case

Time Electronics manufacture a wide range of portable test instruments for sourcing and measuring voltage and current. Products include precision handheld simulators and sources, compact multifunction calibrators, and portable benchtop instruments for laboratory use.

Each model is designed for accuracy and reliability, providing high performance and ease of use for all applications.

1006 DC Millivolt Source

1006 DC Millivolt Source
  • 3 ranges up to 1V
  • 0.02% accuracy
  • 20mA output current
  • Short circuit/overload protection
  • Safety terminals
  • 100 hours typical battery life
  • Supplied with protective cover

1007 DC Millivolt Potentiometer & Calibrator

1007 DC Millivolt Potentiometer & Calibrator
  • 3 ranges up to 1V
  • 0.02% accuracy
  • 20mA output current
  • Short circuit/overload protection
  • LED null measuring facility
  • 100 hours typical battery life
  • Portable with protective cover

1010 DC Voltage Calibrator

1010 DC Voltage Calibrator
  • 0.01μV to 10V in 5 ranges
  • 0.02% accuracy
  • Battery or mains operation
  • 30mA output current
  • 10ppm/hr stability
  • Battery level indicator
  • Safety terminals

1017 Voltage/Current/Resistance Calibrator

1017 Voltage/Current/Resistance Calibrator
  • DC Volts 10nV to 100V
  • DC Current 100nA to 100mA
  • Resistance 10mΩ to 10kΩ
  • 0.005% (50ppm) accuracy
  • 1 ppm setting resolution
  • Noise <2ppm (0.1 to 1Hz)
  • Stability <5ppm/day, <25ppm/yr

1021 DC Current Source

1021 DC Current Source
  • 0 to 100mA in 3 ranges
  • 0.02% accuracy
  • 25ppm/hr stability
  • Up to 40V output drive
  • LED null measuring facility
  • Safety terminals
  • Supplied with protective cover

1024 DC Current Calibrator

1024 DC Current Calibrator
  • 0 to 100mA output in 5 ranges
  • 0.02% accuracy
  • 10ppm/hr stability
  • Up to 15V output drive
  • Null measuring facility
  • Safety terminals
  • Battery or mains operation

1030 Voltage and Current Source

1030 Voltage and Current Source
  • 10mV, 100mV, 1V ranges
  • 10mA, 100mA ranges
  • 0.1% accuracy
  • 0 to 8V available
  • Precision 10-turn dial
  • Battery level indicator
  • Battery powered 9V PP3

1048 Voltage/Current/Loop Calibrator

1048 Voltage/Current/Loop Calibrator
  • Source/measure current & voltage
  • 3 Source ranges to 22mA or 22V
  • 3 Measure ranges to 70mA or 50V
  • Transmitter simulator/sink
  • Output steps and ramps
  • Fine adjustment (inching)
  • Accuracy 0.02% of span

1077 Milliamp Transducer Simulator

1077 Milliamp Transducer Simulator
  • 3 operating modes
  • 100mA source and load
  • 24V line mode
  • 0.02% accuracy
  • Safety terminals
  • Battery level indicator