Portable Process & Pressure Instruments

1090 Portable Process Calibrator

  • Measure/simulate thermocouples
  • Measure/simulate PT100
  • Measure/source (µV/mV/mA)
  • Display in °C and °F
  • Automatic CJC - selectable
  • 10 point memory recall
  • Process loops 4-20mA/0-50mA

Time Electronics offer a range of portable process instruments for field and laboratory use. Products include temperature calibrators and simulators for RTD and PT100 applications, and loop instruments for field instrumentation testing of transmitters, transducers and sensors.

Also available is a series of pressure calibration equipment including pressure calibrators, pneumatic and hydraulic hand pumps and digital pressure gauges. Models are designed to be high precision, durable, and simple operation for use across industries.

1048 Voltage/Current/Loop Calibrator

1048 Voltage/Current/Loop Calibrator
  • Source/measure current & voltage
  • 3 Source ranges to 22mA or 22V
  • 3 Measure ranges to 70mA or 50V
  • Transmitter simulator/sink
  • Output steps and ramps
  • Fine adjustment (inching)
  • Accuracy 0.02% of span

1049 PT100 Simulator

1049 PT100 Simulator
  • -200°C to + 800°C
  • ± 0.3°C accuracy
  • Based on ITS 90 EN60751
  • 23 set points
  • Exceeds class A
  • Good temperature stability
  • Passive resistance source

1077 Milliamp Transducer Simulator

1077 Milliamp Transducer Simulator
  • 3 operating modes
  • 100mA source and load
  • 24V line mode
  • 0.02% accuracy
  • Safety terminals
  • Battery level indicator
  • Supplied with protective cover

7000 RTD Temperature Calibrator

7000 RTD Temperature Calibrator
  • 0.05°C accuracy, 0.01°C resolution
  • 0.03Ω accuracy, 0.01Ω resolution
  • 2, 3 and 4 wire connections
  • Read and simulate °C, °F, °K, Ω
  • Ramp and step
  • PT100 plus 7 other RTD types
  • User programmable

7005 Voltage/Current/Loop Calibrator

7005 Voltage/Current/Loop Calibrator
  • Loop source/measure - V or I
  • Measure 0 - 25V or 0 - 125mA
  • Source 0 - 21V or 0 - 50mA
  • Accuracy 0.01%
  • Resolution 1μA or 1mV
  • Programmable ranges
  • Manual step, auto-step & ramp

7006 Loop Simulator & Source

7006 Loop Simulator & Source
  • 4 - 20mA or 0 - 10V loops
  • 7 calibration set-points
  • Accuracy 0.1%
  • TxSim and RxTest modes
  • Autostep output - adjustable rate
  • Battery powered PP3
  • Internal loop drive supply

7007 Loop Signal Indicator

7007 Loop Signal Indicator
  • 4 - 20mA, 0 -10V, 0 - 50V ranges
  • LCD 4 digit display, mA, V, % of rng
  • Accuracy 0.05%
  • RxSim, TxTest, or 50mA/50V modes
  • Internal loop supply, 25mA max
  • Battery powered 9V PP3
  • Supplied with carry case 

7010 Single Channel Pressure Calibrator

7010 Single Channel Pressure Calibrator
  • Vacuum to 600bar versions
  • Accuracy 0.04% of full scale
  • Pneumatic or hydraulic
  • Over-pressure alarm
  • Isolated 24/36V loop supply
  • Loop current measure
  • Mains / battery power

7015 Dual Channel Pressure Calibrator

7015 Dual Channel Pressure Calibrator
  • Vacuum to 600bar versions
  • Accuracy 0.04% of full scale
  • Pneumatic or hydraulic
  • Over- pressure alarm
  • Isolated 24/36V loop supply
  • Loop current measure
  • Mains / battery power

7016 Regulated Low Pressure Calibrator

7016 Regulated Low Pressure Calibrator
  • Regulated low pressure
  • Vacuum to 20bar versions
  • Accuracy 0.04% of full scale
  • Pneumatic
  • Isolated 24/36V loop supply
  • Loop current measure
  • Mains / battery power

7018 Differential Pressure Calibrator

7018 Differential Pressure Calibrator
  • Vacuum, 0.2, 2, 5 & 10bar versions
  • Accuracy 0.04% of full scale
  • Pneumatic
  • Over-pressure alarm
  • Isolated 24/36V loop supply
  • Loop current measure
  • Mains or battery powered

7040 Digital Pressure/Current Calibrator

7040 Digital Pressure/Current Calibrator
  • Vacuum to 20bar versions
  • 0.04% accuracy
  • Loop current calibration
  • 9 engineering units
  • Min / Max function
  • Leak rate function
  • RS-232 serial interface

7050 Process and Thermocouple Calibrator

7050 Process and Thermocouple Calibrator
  • 3 ranges to 40V, 400mA, 40kΩ
  • O/p volt. up to 10V, 1uV resolution
  • O/p I up to 20mA, 1uA resolution
  • O/p R: 0-400Ω, 0.01Ω resolution
  • Thermocouple measure & simulate
  • RTD measure & simulate: PT100
  • Battery / mains operation

7078 Auto-Ranging Digital Pressure Gauge

7078 Auto-Ranging Digital Pressure Gauge
  • Vacuum to 200bar (3000psi)
  • Accuracy 0.1% of reading
  • 9 engineering units
  • Silicone piezo resistive sensors
  • Reads gauge & absolute pressure
  • Easy to read backlit colour display
  • Robust with protective rubber boot

7090 Pneumatic Calibration Pump

7090 Pneumatic Calibration Pump
  • Pressure to 40bar (600psi)
  • Vacuum to -950mbar
  • Oversized check valve
  • Contoured cushioned handles
  • Protective caging for vent valve
  • Hose, fittings, & carry case supplied
  • Optional digital gauges

7091 Digital Pressure Gauge

7091 Digital Pressure Gauge
  • Vacuum to 40bar (600psi)
  • Accuracy 0.2% of full scale
  • Easy-to-read display
  • 5 digit resolution
  • 3 times per second measure speed
  • Analogue dial indicates % pressure
  • Ideal for use with the 7090 pump

7093 Precision Loop and Dual Pressure Calibrator

7093 Precision Loop and Dual Pressure Calibrator
  • Vacuum to 600bar versions
  • Pressure accuracy 0.04% of FS
  • 0.025% high accuracy versions
  • Pneumatic or hydraulic
  • I measure: 125mA, Source: 50mA
  • V measure: 25V, Source: 21V
  • V/I accuracy 0.01%

7094 Digital Pressure Gauge

7094 Digital Pressure Gauge
  • 0 to 100bar (1500psi) pressure
  • Accuracy 0.2% of full scale
  • Easy-to-read display
  • 5 digit resolution
  • 3 times per second measure speed
  • Analogue dial indicates % pressure
  • Ideal for use with the 7194 pump

7095 Hydraulic Calibration Pump

7095 Hydraulic Calibration Pump
  • 0 to 700bar (10,000psi) 
  • Priming feature for fast air purge 
  • Oversized check valve
  • Contoured cushioned handles
  • Built-in pressure relief valve  
  • Hose, fittings, & carry case supplied
  • Optional digital gauge

7096 Digital Pressure Gauge

7096 Digital Pressure Gauge
  • Pressure up to 700bar
  • Accuracy 0.2% of full scale
  • Up to 5000 hours battery life
  • Easy-to-read display
  • 5 digit resolution
  • 3 times per second measure speed
  • Ideal for use with the 7095 pump

7194 Pneumatic Pressure Calibration Pump

7194 Pneumatic Pressure Calibration Pump
  • 0.95bar vacuum to 100bar (1500psi)
  • Dual pressure source
  • High pressure resolution
  • High pressure stability
  • Easy to use pressure lever/handle
  • Free from humidity and dirt
  • For reference calibration with gauge

7195 Hydraulic Pressure Calibration Pump

7195 Hydraulic Pressure Calibration Pump
  • 0.9bar vacuum to 600bar (8700psi)
  • Dual pressure source
  • High pressure resolution
  • High pressure stability
  • Smooth pressure generation
  • Oil or deionized water
  • For reference calibration with gauge