5025 Multifunction Calibrator

5025 Multifunction Calibrator

Features

  • 0 - 1050V & 0 - 22A (AC/DC)
  • 1Ω to 1GΩ resistance
  • Thermocouple simulation
  • Oscilloscope calibration option
  • PT100, C & L, and power options
  • Clamp meter calibration
  • EasyCal software compatible
 

A high performance multi-product calibrator that provides the foundation for fast and cost-effective calibration. Designed for a wide workload the 5025 can be used to accurately test and verify both traditional and new test equipment.

The standard unit is fitted with AC/DC voltage to 1050V, AC/DC current to 22A, digital frequency to 10MHz, decade resistance to 1GΩ, conductance and thermocouple simulation. Further options enhance calibration capabilities and can be added as per customer requirement.

Multi Instrument Calibration
The 5025 can calibrate various instruments and devices; digital and analogue multimeters, frequency meters, ohm meters, AC/DC millivoltmeters, thermocouple indicators, clamp meters, temperature indicators, timer counters, oscilloscopes, and much more.

Simple Operation
Functions and ranges are easily accessed from the front panel. Increase and decrease keys per digit, are used to quickly set the output value. Deviation control then enables the user to finely adjust the output value as a percentage (+/- 9.999%). All this information is shown on an easy to read LED display.

Flexible Options
A range of options provide added functionality and features. Internal additions include capacitance and inductance, wideband AC voltage, full range resistance (incorporating PT100 simulation), power calibration, and oscilloscope calibration. External adaptors are available for clamp meter calibration (up to 1100A), optical tachometer calibration, and torque wrench calibration. Also available are accompanying instruments that can be used with the 5025 for specific applications. These include low noise attenuators, a 100A current transformer, and a power amplifier for demanding analogue instruments. 

EasyCal Software - Manage, Automate and Optimise the Calibration Process
Connect the 5025 to a PC/Laptop (via RS233, GPIB or USB) installed with Time Electronics’ EasyCal software and automate the calibration process. This provides increased speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards.

Standard Features

Function Range Best 1 year Specification
Voltage DC 0 to ± 1050V ± 15ppm of setting
Current DC 0 to ± 22A ± 80ppm of setting
Voltage AC 1mV to 1050V (10Hz to 20kHz, sine-wave) ± 300ppm of setting
Current AC 10μA to 22A (20Hz to 1kHz, sine-wave) ± 0.05% of setting
Resistance 1Ω to 1GΩ (Fixed values, decade steps) ± 20ppm of setting
Conductance 1S to 1nS (Fixed values, decade steps) ± 20ppm of setting
Thermocouple Simulation -270 to 1800°C (Type J, K, R, T, S, B, E, N) ± 0.15°C

10MHz Digital Frequency/Period

0.1Hz to 10MHz / 100ns to 10s

± 20ppm of setting


Options

Option (code in brackets) Range / Values Best 1 year Specification
Wideband AC Voltage (9771) 20 to 200mV/300kHz. 0.2 to 2V/1MHz. 2 to 20V/100kHz ± 0.05% of setting
Capacitance (9798) 1nF, 10nF, 100nF, 1μF, 10μF, 100μF ± 0.25% of setting

Inductance (9798)

1, 1.9, 5, 10, 19, 50, 100, 190, & 500mH, 1H, 10H

± 0.1% of setting

Full Range Resistance (9787)
- PT100 

1Ω to 120MΩ (Variable)
-200 to 850°C

± 100ppm of setting
± 0.2°C 

Oscilloscope Calibration (9770)
- Amplitude
- Frequency/Period 
- Duty Cycle
- Fast-Rise
- 2.2GHz Sweep (9769) 


0mV to 200V and 0mV to 2V 50Ω (square-wave or DC)
0.1Hz to 100MHz / 100ns to 10s
3 frequencies: 100Hz, 1kHz, 10kHz, settable from 0 to 100%
<850ps. Bandwidth checking up to 400MHz
100MHz to 2.2GHz levelled sine-wave (0.5, 1, 1.5V pk-pk)


± 0.05%
± 20ppm (± 0.1ppm option 9783)


Amplitude ± 1%, Frequency ± 20ppm

Power Calibration (9797)

- Phase/Power Factor
- External Enhancements 

22A, 1050V, 23kW, 45 to 400Hz

± 90°/ 0.00 to 1.00PF
AC Current Transformer (9790): 100A / 100kW.
Clamp Meter Adaptor x50 turn (9780): 1100A / 1.1MW 

ACV: 0.03%, DCV: 0.01%
ACI: 0.1%, DCI: 0.03%
± 0.3°

Full details on the available external options are shown in the Models / Options tab.


General Specifications

Warm up 30 minutes to full accuracy
Settling Time Less than 5 seconds
Standard Interfaces GPIB (IEEE-488), RS-232, USB

Temp Performance

Operating: 5 to 40°C, Full Spec: 22°C +/- 3°C, Storage: -10°C to 50°C

Operating Humidity

< 80% non condensing

Operating Altitude 0 to 3km. Non operating: 3km to 12km
Line Power 100 to 230V AC 50/60 Hz. 200W maximum
Dimensions W455 x H155 x D480mm
Weight 16.5kg
Country of Origin UK
Supplied With User manual, RS-232 cable, and USB adaptor/cable

For a full list of options please see the Models/Options tab.
For full specifications and further details please see the PDF Data Sheets in the Download tab. 

Models

5025

Multifunction Calibrator

Internal Options
9798 Capacitance (1000pF - 100μF) / Inductance (1mH - 10H)
9774 Simulated Resistance (10Ω - 40MΩ)
9787 Full Range Resistance (1Ω - 120MΩ) - incorporating PT100 Simulation
9771 Wideband AC Voltage (1MHz Max. 20mV - 20V)
9797 Power Calibration (0 - 20KW AC and DC)
9770 Oscilloscope Calibration (1mV - 200V, 0.1Hz - 100MHz)
9769 Scope 2.2GHz Levelled Sine Generator

9783

Oven-Controlled High Stability Frequency Reference (increases frequency accuracy from 20ppm to 0.1ppm)

External Options and Calibration Certificates

9762

Rubidium Frequency Reference (9770 Scope option must be fitted) - View data sheet

9764

Current Probe Calibration Adaptor (9770 Scope option must be fitted) - View data sheet

5065

6.5 Digit Bench Multimeter - View data sheet  /  View web page

9780

Clamp Meter Adaptor (1 & 50 turn coil) - View data sheet

9773

Optical Tacho Adaptor - View data sheet

9790

100 Amp AC Current Transformer - View data sheet

9760

Power Amplifier (60V AC, 90V DC - 100mA) - View data sheet

9766

External Low Noise Attenuator 1000:1 - View data sheet

9767

External Low Noise Attenuator 100:1 - View data sheet

9759

Torque Wrench Calibration Adaptor

9085 Soft Carry Case for 5025
9728 19” Universal Rack Mount Kit

9541

Basic Test Lead Set - View data sheet

9796

Premium Test Lead Set - View data sheet

C159

Factory Calibration Certificate (NPL traceable)

C103 UKAS Calibration Certificate (ISO 17025)
C113 Extended UKAS Calibration Certificate (ISO 17025)
Calibration Software and Accessories

ECFLA

EasyCal Full License - when purchased with multifunction calibrator/DMM: Discounted full license with 1 year support. 
For further licenses and EasyCal add-ons see the Easycal web page or PDF brochure

9795

Printer & Connectivity Kit (Printer, DVD-RW, 4 Port USB Hub, Numeric Key Pad & USB Memory Stick)

9777 Bar Code Reader
9778 Cal and ID Label Printer

9779

Job and Address Label Printer

9743 PCI - GPIB interface card
9794 USB - GPIB Adaptor
9597 GPIB Cable

9588

RS-232 Cable

ESP1 EasyCal Support Package 1: 1 year email and telephone support. Minor upgrades.
ESP2 EasyCal Support Package 2: 2 year email and telephone support. Minor upgrades.
EOT1 EasyCal Online Training Session (Via Remote Desktop)
PDF Downloads
File Name File Size Language

5025 Data Sheet

365kB

EN

5025 Extended Specifications

190kB

EN

EasyCal Brochure

3MB (Low resolution)

EN

EasyCal Brochure

7MB (Higher resolution)

EN

Data sheets for various external options shown in Models/Options tab