Decade Boxes

1051 - 8 Decade Resistance Box

  • 0.01Ω to 1MΩ
  • High accuracy & stability
  • Clear visual indication
  • Safety terminals
  • Low temperature coefficient
  • Suitable for PRT/RTD
  • Supplied with protective cover

Time Electronics manufacture a complete range of decade boxes, designed for resistance, capacitance, and inductance. These precision instruments cover the requirements of both field and laboratory work, and are commonly used in educational establishments.

Each decade box is high performance, delivering accuracy, stability, and ease of use for applications.

1040 - 8 Decade Resistance Box

1040 - 8 Decade Resistance Box
  • 1Ω to 100MΩ
  • High accuracy
  • Clear visual indication
  • High stability
  • Safety terminals
  • Low temperature coefficient
  • Supplied with protective cover

1041 - 5 Decade Resistance Box

1041 - 5 Decade Resistance Box
  • 0.01Ω to 1kΩ
  • 10mΩ resolution
  • Ideal for PRT/RTD
  • High stability
  • Safety terminals
  • Low temperature coefficient
  • Supplied with protective cover

1049 PT100 Simulator

1049 PT100 Simulator
  • -200°C to + 800°C
  • ± 0.3°C accuracy
  • Based on ITS 90 EN60751
  • 23 set points
  • Exceeds class A
  • Good temperature stability
  • Passive resistance source

1050 PT100 Simulator

1050 PT100 Simulator
  • -100°F to + 1000°F
  • ± 0.5°F accuracy
  • Based on ITS 90 EN60751
  • 23 set points
  • Exceeds class A
  • Good temperature stability
  • Passive resistance source

1053 - 4 Decade Inductance Box

1053 - 4 Decade Inductance Box
  • 1mH to 10H
  • In-line readout
  • 3% accuracy
  • High stability
  • Safety terminals
  • Fully screened
  • Robust and portable

1061 - 6 Decade Resistance Box

1061 - 6 Decade Resistance Box
  • 1Ω to 1.2MΩ
  • In-line readout
  • Stable metal film resistors
  • Mechanically/electrically robust
  • Safety terminals
  • Fully screened

1065 - 6 Decade Power Resistance Box

1065 - 6 Decade Power Resistance Box
  • 0.1Ω to 120kΩ
  • 1% accuracy
  • 10W per resistor dissipation
  • Residual resistance < 20mΩ
  • In-line readout
  • Mechanically/electrically robust
  • Fully screened

1067 - 6 Decade Precision Resistance Box

1067 - 6 Decade Precision Resistance Box
  • 10mΩ to 12kΩ
  • 0.01% accuracy
  • Precision PT100 simulation
  • 6 digit resolution
  • Better than 20ppm/year stability
  • Residual resistance < 10mΩ
  • Fully screened

1068 - 5 Fixed Resistance Box

1068 - 5 Fixed Resistance Box
  • 5 fixed resistance ranges
  • High accuracy
  • Clear visual indication
  • Portable and compact
  • Simple operation
  • Robust casing
  • Ideal for education

1070 - 5 Decade Capacitance Box

1070 - 5 Decade Capacitance Box
  • 100pF to 10μF
  • 1% Accuracy
  • In-line readout
  • Colour coded digits
  • Safety terminals
  • Bi-polar working
  • Supplied with protective cover

1071 - 7 Decade Capacitance Box

1071 - 7 Decade Capacitance Box
  • 10pF to 100μF
  • 1% accuracy
  • In-line readout
  • Colour coded digits
  • Safety terminals
  • Bi-polar working
  • Supplied with protective cover

5069 Insulation Tester Calibrator

5069 Insulation Tester Calibrator
  • 100KΩ to 100GΩ
  • Basic accuracy 1%
  • Up to 10kV operation
  • Battery operation
  • Fully shrouded safety connectors
  • Display of open circuit voltage
  • Display of short circuit current