Quick and Easy Oscilloscope Calibration to 600MHz
The 5045 is a versatile, high accuracy calibrator capable of calibrating digital and analogue oscilloscopes, timer/counters, and frequency meters.
It provides a wide range of outputs for amplitude, frequency, period and bandwidth. Amplitude calibration is achieved by a DC signal or 1kHz square-wave, ranging from 1mV to 220V (2V max for 50 ohm loads). Deviation up to ±9.99% allows fine adjustment of amplitude and direct readout of error.
Accurate frequencies are generated from a temperature controlled quartz crystal oscillator. Alternatively a 10MHz reference input in can be used. Timing accuracy of 0.1ppm is suitable for most oscilloscopes and timer counters. A precise square-wave output provides a fast rise time of less than 300ps, which allows bandwidth testing up to 600MHz.
Simple Operation
Functions and ranges are easily accessed from the front panel. Increase and decrease keys per digit, are used to quickly set the output value. Deviation control then enables the user to finely adjust the output value as a percentage (+/-9.99%). All this information is shown on an easy to read LED display.
Virtual Front Panel Software
The 5045 is supplied as standard with Time Electronics’ windows based ‘Virtual Front Panel’ interface. This enables the user to control the instrument via a laptop or PC.
2GHz Levelled Sine-Wave Option
For precise bandwidth determination and frequency response analysis the 2GHz option is available. The ability to sweep the frequency output from 10MHz to 2GHz and adjust the amplitude from 0.5V to 1.5V pk-pk ensures accurate analysis of oscilloscope input amplifiers.
Current Probe Calibration
For calibration of oscilloscope current probes an external adaptor is available. This converts the 5045’s amplitude output to current and covers the range 0.1mA to 100mA pk-pk, 0.2% accuracy, DC or 1kHz.
Rubidium frequency reference
Enhanced timing performance is available by specifying the rubidium high stability frequency reference option (9762). This option achieves timing accuracies required to calibrate high performance timer/counters to 1 part in 10^10.
EasyCal Software - Manage, Automate and Optimise the Calibration Process
To automate the oscilloscope calibration process the 5045 can be controlled using Time Electronics’ EasyCal calibration software. This provides increased speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards.
| Standard Features |
|---|
| Function | Range | Specification (± output + floor) | Resolution |
|---|---|---|---|
Frequency* | 0.1Hz to 10MHz | ± 0.1ppm | Fixed Outputs in 1,2,5,10 Sequenced Steps |
Period* | 10s to 100ns | ± 0.1ppm + 30ps | Fixed Outputs in 1,2,5,10 Sequenced Steps |
Duty Cycle | 100Hz, 1kHz, 10kHz | Settable from 0 to 100% | - |
Amplitude DC or 1kHz Square wave | 10mV to 200mV | ± 0.2% + 10μV | 10μV |
Fast Rise | 10MHz (200mV pk/pk) | Rise Time less than 300ps | - |
*Frequency amplitude: 1.5V pk-pk 0.1Hz to 100kHz. 1V pk-pk 200kHz to 100MHz.
2GHz Sweep (9769) - Levelled Sine-Wave |
|
Rubidium Reference (9762) |
Rubidium atomic clock 10MHz frequency reference. |
Current Probe Adaptor (9764) |
Battery powered external adaptor for checking current probes. 0.1 to 100mA, 0.2% accuracy. |
| Warm up | 30 minutes to full accuracy |
| Settling Time | Less than 5 seconds |
| Standard Interfaces | GPIB (IEEE-488), RS-232, USB |
| Temp Performance | Operating: 10 to 40°C, Full Spec: 23°C +/- 5°C, Storage: -10°C to 50°C |
| Operating Humidity | < 80% non-condensing |
| Operating Altitude | 0 to 3km. Non operating: 3km to 12km |
| Line Power | 100 - 230V AC 50/60Hz. Power Consumption 60W typical, 80W Max. |
| Dimensions | W450 x D272 x H152mm (18 x 11 x 7”) |
| Weight | 8.2kg (18lbs) |
| Country of Origin | UK |
Supplied With |
Virtual control software, user manual, RS-232 cable, and USB adaptor/cable |
| Models |
|---|
5045 |
Oscilloscope Calibrator |
| Options |
|---|
9769 |
Internal Scope 2GHz Levelled Sine Generator |
9762 |
Rubidium High Stability Frequency Reference - View data sheet |
9764 |
Current Probe Calibration Adaptor - View data sheet |
| 9519 | 9 Piece Adaptors and Test Lead Set |
| 9728 | 19” Universal Rack Mount Kit |
| C147 | Factory Calibration Certificate (NPL traceable) |
| C128 | UKAS Calibration Certificate (ISO 17025) |
| Calibration Software and Accessories |
|---|
ECFLA |
EasyCal Full License - when purchased with multifunction calibrator/DMM: Discounted full license with 1 year support. |
9795 |
Printer & Connectivity Kit (Printer, DVD-RW, 4 Port USB Hub, Numeric Key Pad & USB Memory Stick) |
| 9777 | Bar Code Reader |
| 9778 | Cal and ID Label Printer |
9779 |
Job and Address Label Printer |
| ESP1 | EasyCal Support Package 1: 1 year email and telephone support. Minor upgrades. |
| ESP2 | EasyCal Support Package 2: 2 year email and telephone support. Minor upgrades. |
| EOT1 | EasyCal Online Training Session (Via Remote Desktop) |
| PDF Downloads |
|---|
| File Name | File Size | Language |
|---|---|---|
500kB | EN | |
3MB (Low resolution) | EN | |
7MB (Higher resolution) | EN | |
167kB | EN | |
272kB | EN |