ATE / Bench Calibrators & DMMs

5075 7.5 digit Multimeter

  • 7½ digit resolution
  • AC/DC voltage & current
  • Resistance & temperature
  • Capacitance & frequency
  • 18ppm/year accuracy
  • 10 channel scanner option
  • EasyCal software compatible

Time Electronics offer a range of calibrators and digital multimeters that can be used in the lab or in automated testing applications. These programmable instruments are designed for precision, performance, and functionality, making them ideal for automatic testing and fault diagnosis. Each designated ATE calibrator is rack mountable for straightforward integration into user systems.

In the laboratory EasyCal calibration software can be used with compatible models to increase speed of calibration, consistency of results and produce calibration certificates and reports.

5011 Resistance / Temperature Calibrator

5011 Resistance / Temperature Calibrator
  • 1Ω to 120MΩ
  • RTD & thermocouple simulation
  • DCV and DCI options
  • 10MHz frequency option
  • RS-232 / GPIB / USB interfaces
  • Front panel operation
  • EasyCal Software compatible

5018 Programmable DC/AC V/I Calibrator

5018 Programmable DC/AC V/I Calibrator
  • 0 - 22V DCV (30V DC optional)
  • 0 - 22V AC, 220V & 1kV DC options
  • Optional 0 - 220mA AC/DC
  • Ramping feature
  • GPIB / RS-232 / USB interfaces
  • Ideal for ATE applications
  • EasyCal Software compatible

5025 Multifunction Calibrator

5025 Multifunction Calibrator
  • 0 - 1050V & 0 - 22A (AC/DC)
  • 1Ω to 1GΩ resistance
  • Thermocouple simulation
  • Oscilloscope calibration option
  • PT100, C & L, and power options
  • Clamp meter calibration
  • EasyCal software compatible

5025E Multifunction Calibrator

5025E Multifunction Calibrator
  • 0 - 1050V & 0 - 22A (AC/DC)
  • 10Ω to 1GΩ resistance
  • Thermocouple & PT100 simulation
  • Digital frequency
  • Optional clamp meter calibration
  • Scope and power options
  • EasyCal software compatible

5030 Electrical Tester Calibrator

5030 Electrical Tester Calibrator
  • RCD: 3 - 2500mA, 10 - 2000ms
  • Loop 50mΩ to 1.8kΩ
  • Insulation up to 2GΩ / 1kV
  • Continuity 0.1Ω to 10kΩ
  • RS-232 / USB Control
  • Fast and intuitive user interface
  • EasyCal software compatible

5033 3 Channel DC Power Source

5033 3 Channel DC Power Source
  • 3 independent channels
  • 0 to 20V DC 2A drive capability
  • 40 watts max per channel
  • 10μV resolution setting
  • Programmable via GPIB interface
  • Easy to use command language
  • 4 Terminal Output

5045 Oscilloscope Calibrator

5045 Oscilloscope Calibrator
  • 10mV to 220V square wave/DC
  • Frequency 0.1 to 100MHz
  • Time markers 10s to 10ns
  • Fast rise <300ps
  • Front panel or PC control
  • 2GHz sweep & rubidium options
  • EasyCal software compatible

5051Plus Multifunction Calibration System

5051Plus Multifunction Calibration System
  • Combined calibrator/DMM/PC
  • 0 - 1050V & 0 - 22A (AC/DC)
  • Source up to 1GΩ resistance
  • Thermocouple simulate/measure
  • PT100, C & L, scope calibration
  • Clamp meter calibration
  • EasyCal Software included

5065 6.5 digit Multimeter

5065 6.5 digit Multimeter
  • Resolution 6 1/2 digits
  • Accuracy: 0.005% DC voltage
  • USB interface
  • Optional GPIB interface
  • Temperature measurements
  • 10 channel scanner option
  • EasyCal software compatible

5077 Power Calibrator

5077 Power Calibrator
  • 20mA to 22A AC/DC
  • 100A AC I transformer option
  • 1mV to 1050V AC/DC
  • +90.0 deg to -90.0 deg
  • 0.00 to 1.00 Lead/Lag
  • 45 to 400 Hz in 0.1Hz steps
  • RS-232 / GPIB / USB interface