Pressure Tools and Instruments

Pressure Pumps and Gauges

7090

Pneumatic Hand Pump (-950mbar to 40bar). View Data Sheet

7095

Hydraulic Hand Pump (0 to 700bar). View Data Sheet

7194

Benchtop pneumatic pump (0.95bar vacuum to 100bar). View Data Sheet

7195

Benchtop hydraulic pump (0.9bar vacuum to 600bar). View Data Sheet

7091

Digital Pressure Gauge (Vacuum to 40bar, 0.2% Accuracy). View Data Sheet

7094

Digital Pressure Gauge (0 to 100bar, 0.2% Accuracy). View Data Sheet

7078

Auto Ranging Digital Gauge (Vacuum to 200bar, 0.1% Accuracy). View Data Sheet

7096

Digital Pressure Gauge (0 to 700bar, 0.2% Accuracy). View Data Sheet

7149

Electrical Vacuum Pump. View Data Sheet

Dead Weight Testers

7890

Hydraulic Dead Weight Tester (1 to 700bar, 0.015% accuracy) 

7891

Hydraulic Dead Weight Tester (1 to 1200bar, 0.015% accuracy) 

7892

Hydraulic Dead Weight Tester (1 to 2600bar, 0.02% accuracy) 

7893

Pneumatic Dead Weight Tester (1 to 120bar, 0.015% accuracy) 

Fittings and Adaptor Kits

7073

Low pressure connection/adaptor kit (< 20bar). View Data Sheet

7097

BSP to Minimess Adaptor Test Kit. View Data Sheet

7198

Adaptors and Fittings Kit. View Data Sheet

Compressors, Air Amplifiers, and Gas Boosters

7173

9bar Heavy Duty Compressor . View Data Sheet

7174

10bar Silent Running Compressor. View Data Sheet

7175

Double End Air Amplifier System. Regulated output pressure up to 34bar. Requires 7bar min line pressure.

7176 Gas Booster Power Unit (for high output pressure). Versions available for 200 - 600bar output. Requires 8bar min line pressure.


Process Instruments

Dry Block Calibrators
Model Temp Range Heating Time Accuracy Stability Immersion Depth Insert Diameter

7070

-17 to 140°C

15 min

0.4°C

0.05°C

115mm

19mm

7071 33 to 320°C 4 min 0.5°C 0.1°C 110mm 26mm
7072 33 to 650°C 20 min 0.9°C 0.1°C 110mm 26mm

Additional field calibrators for pressure and process applications are available from the Time Electronics standard range.

Repair / Maintenance Equipment and Accessories

7144

Standard Benchtop Solder Station. View Data Sheet

7145

Advanced Benchtop Solder Station and Rework Kit. View Data Sheet

7147 Benchtop fume extraction kit

7150

Heavy Duty Vice with turntable (jaw width: 100, 125, or 150mm). View Data Sheet

7180

Table top Circuit Board Holder. View Data Sheet

7181

Magnifying Lamp (175mm diameter, 1.75x magnifying lens). View Data Sheet

7154 Benchtop turntable with locking mechanism

7183

Electronics service case (82 tools). View Data Sheet

7166 Tool Box - Heavy duty steel (W690 x D360 x H312mm)
Standard ESD Equipment Options
7185 Melamine Faced ESD Worktop for bench. Chipboard, conductive core, 3mm ABS edges, antistatic, scratch, impact and stain resistant.

7186

ESD Workstation Kit for CalBench: Includes benchtop mat, signage, bonding plugs, wrist strap and leads. View Data Sheet

Additional items upon request, including:

• Grounding products

• Anti-static wrist wraps

• Anti-static labels, tapes, and bags

• Heel and toe grounders

• Static test meters 

Additional Calibration Tools and Test Kits

7151

Vernier and Micrometer Calibration Kit

7179A

Test Weight Set (Stainless steel F1 class, 6110g total weight):
1x1, 2x2, 1x5, 1x10, 2x20, 1x50, 1x100, 2x200, 1x500, 1x1000g, 2 x 2000g. View Data Sheet

7179B

Test Weight Set (Stainless steel F1 class, 11110g total weight):
1x1, 2x2, 1x5, 1x10, 2x20, 1x50, 1x100, 2x200, 1x500, 1x1000g, 2 x 2000g, 1 x 5000g. View Data Sheet

Other items available upon request. Portable and benchtop calibration instruments from the standard Time Electronics range.