As a guideline for customers Time Electronics have configured several packages to cover common industrial calibration applications. Each package is designed to provide the end user with a system for multi product calibration, with modules to cover the testing workload.
Each package can be customised as required, with a wide range modules and extras available for inclusion into each system.
The CalBench Universal Package is for test facilities requiring a complete multi-product calibration and testing solution. Items have been carefully selected to provide a range of comprehensive features to enhance and optimise the calibration process.
Calibrate these common devices/instruments and much more:
• Pressure: Gauges, Calibrators, Transducers, Transmitters, Indicators, Switches, Valves.
• Temperature and Loop: Sensors, Indicators, Thermocouple and RTD Transmitters, Calibrators, PRTs, Thermistors.
• Electrical/Electronic: Multimeters, AC/DC Signal Sources, Clamp Meters, Tachometers, Ohmmeters, Decade Boxes, Power Supplies.
• Frequency: Signal Generators, Oscilloscopes, Frequency Meters, Timer Counters.
| Universal CalBench Package (Order code: CBUP) |
|---|
| Item# | Code | Description | Purpose |
|---|---|---|---|
1 | 7080 | CalBench (W2000 x D850 x H1568): Height adjustable bench frame, work top, primary console with 7082 mains power control and distribution module (incl. 2 x output sockets), 4 x under console sockets, and under console lighting. | Provides an ergonomic workspace for various calibration and testing applications. A wide range of modules can be fitted to the primary console creating a highly flexible system that is both functional and easy to use. |
| 2 | 7081 | Secondary Console (W2000 x D225 x H390 mm) | Fitted directly below primary console to house additional modules. |
| 3 | 7121 | 2 drawer Unit (W500 x D550 x H250mm) | For general use and keeping documents etc |
4 | 7087 | Quad DC Power Supply Module - 6V(8A), 12V(8A), 24V(4A), 48V(3A) | Provides a DC power supply to various loop instrumentation under test. |
5 | 7053 | 56V DC 4A Adjustable Power Supply Module - Digital | Provides a variable precision DC power supply for a various applications. |
6 | 7088 | Adjustable AC Supply Module (0 - 265V/10A at 240V input or 0 - 121V/10A at 110V input) | Provides a variable AC supply to for electrical/electronic devices under test. |
7 | 7051+ | Multifunction Calibrator & Control Centre Module: • Integral calibrator, 6.5 digit DMM, touch screen PC • Source up to 1050V AC/DC voltage • Source up to 22A AC/DC current • Source up to 1GΩ resistance • Thermocouple simulate and measure • PT100 simulate and measure • Source capacitance and inductance • Oscilloscope calibration • Clamp meter adaptor & tacho meter adaptor • EasyCal calibration software, printer kits, bar code reader and more extras included | Allows automated calibration for a wide range of electronic test, pressure, temperature and electrical instrumentation. Provides precision electronic calibration source and measurement functions to calibrate a wide range of digital and analogue multimeters, frequency meters, ohm meters, AC/DC millivoltmeters, decade boxes, thermocouple indicators and sensors, clamp meters, oscilloscopes, timer counters, RTDs. Further to this it provides communication with pressure modules. EasyCal enables the user to automate the calibration process and increase speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards. |
8 | 9769 | 7051 internal option: Scope 2.2GHz Levelled Sine Generator | Enhances the 7051's oscilloscope calibration capabilities. |
9 | 7085A | Auto Switching Temperature Distribution Module | Allows 7 thermocouple types to be batch calibrated as well as providing an RTD reference. |
10 | 7067 | Precision Loop Calibrator Module | Provides secondary manual control loop calibration and test. |
11 | 7068 | RTD Temperature Calibrator Module | Provides a secondary manual control temperature calibrator. |
12 | 5068B | Insulation Tester Calibration Module | Allows insulation testers to be calibrated (up to 2.5kV). |
13 | 9758B | DC Electronic Load Module, 80A, 80V, 300W | Provides a precision controlled DC load for calibrating DC power supplies. |
14 | 7059/7101 | Vacuum/Pressure Calibrator (VAC + 2bar) | Allows vacuum and low range pressure instruments, switches, gauges, transmitters, transducers to be calibrated. |
15 | 7062/7103 | Pressure Calibration module with regulator (10bar) | Allows calibration of mid range pressure devices. |
16 | 7062/7104 | Pressure Calibration module with regulator (20bar) | Allows calibration of mid range pressure devices. |
17 | 7064/7107 | High Pressure Calibration module with regulator (100bar) | Allows calibration of high range pressure devices. |
18 | 7064/7108 | High Pressure Calibration module with regulator (200bar) | Allows calibration of high range pressure devices. |
| 19 | 7066/7102 | Differential Pressure Calibration module (5bar) | Allows calibration of differential pressure instrumentation below 5bar. |
20 | 7066/7103 | Differential Pressure Calibration module (10bar) | Allows calibration of differential pressure instrumentation below 10bar. |
21 | 7038/7109 | Multi Function Pressure Indicator (400bar) | Additional high pressure indication. Used for calibration with the 7195 hydraulic pump input. |
22 | 7038/7110 | Multi Function Pressure Indicator (600bar) | Additional high pressure indication. Used for calibration with the 7195 hydraulic pump input. |
23 | 7198 | Multi Adaptors/Fittings Kit with case | Provides all the required pressure connections and fittings for modules and pumps. |
24 | 7149 | Electrical Vacuum Pump | To supply the 7059 module a vacuum pressure source. |
| 25 | 7194 | Desktop Pneumatic Pump (Vacuum to 100bar) | For manual pressure generation up to 100bar |
26 | 7094 | Digital Pressure Gauge (0 to 100bar, 0.25% Accuracy) | Secondary reference (back up or field use). |
27 | 7195 | Desktop Hydraulic Pump (0 to 600bar) | Provides pressure input to the 7038 modules up to 600bar |
28 | 7096 | Digital Pressure Gauge (0 to 700bar) | Secondary reference (back up gauge) |
29 | 7072 | Dry Block Calibrator (33 to 650 degC) | For calibrating temperature probes, RTDs, and more |
30 | CERTS | Factory Calibration Certificates for test modules | Certifies all calibration modules have been tested in the TE factory (NPL traceable) |
The CalBench Universal Package can be customised per requirement. Options include:
• Replacing or removing non-required modules. Add others from the TE CalBench range.
• Additonal external items for other calibration applications: Dimensional, torque, weight, etc
• Line pressure requirements: This system can use up 200bar line pressure. Hand pumps can also be used (7194 and 7195) or compressors and boosters can be supplied.
• Additional fittings and furniture: Under worktop drawers and cabinets, PC holders. Also side tables and laboratory furniture.
• Software add-ons and licenses: For customers requiring additional EasyCal features and workstation licenses.
• Laboratory design and supply: For the turnkey solution to design, install, commission, and train end users.
• CalBench Training: On-site or at the Time Electronics factory, UK.
The CalBench Auto Process Package is for test facilities requiring a process control orientated calibration and testing solution. The system uses both software and modules for rapid calibration of various equipment common to process plants.
Calibrate these common devices/instruments and much more:
• Pressure: Gauges, Calibrators, Transducers, Transmitters, Indicators, Switches, Valves.
• Temperature and Loop: Sensors, Indicators, Thermocouple and RTD Transmitters, Calibrators, PRTs, Thermistors.
• Electrical/Electronic: Ohm Meters, Millivoltmeters, Decade Boxes
| Auto Process CalBench Package (Order Code: CBAPP) |
|---|
| Item# | Code | Description | Purpose |
|---|---|---|---|
| 1 | 7080 | CalBench (W2000 x D850 x H1568): Height adjustable bench frame, work top, primary console with 7082 mains power control and distribution module (incl. 2 x output sockets), 4 x under console sockets, and under console lighting. | Provides an ergonomic workspace for various calibration and testing applications. A wide range of modules can be fitted to the primary console creating a highly flexible system that is both functional and easy to use. |
| 2 | 7081 | Secondary Console (W2000 x D225 x H390 mm) | Fitted directly below primary console to house additional modules. |
| 3 | 7121 | 2 drawer Unit (W500 x D550 x H250mm) | For general use and keeping documents etc. |
| 4 | 7087 | Quad DC Power Supply Module - 6V(8A), 12V(8A), 24V(4A), 48V(3A) | Provides a DC power supply to various loop instrumentation under test. |
| 5 | 7053 | 56V DC 4A Adjustable Power Supply Module - Digital | Provides a variable precision DC power supply for a various applications. |
6 | 7051 | CalBench Control Centre & Multifunction Calibrator Module: • Integral Calibrator, 6.5 digit DMM, Touch Screen PC • Source up to 22V AC/DC voltage • Source up to 220mA AC/DC current • Source up to 1GΩ resistance • Thermocouple simulate and measure • PT100 simulate and measure • EasyCal calibration software and printer kit | Automated multi product device calibration and communication with pressure modules (readback via EasyCal). Calibrate Sensors, Indicators, Thermocouple and RTD Transmitters, Calibrators, PRTs, Thermistors.
EasyCal enables the user to automate the calibration process and increase speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards. |
| 7 | 9787 | 7051 internal option: Full Range Resistance | Provides true resistance function for resistance substitution, select on test, RTD calibration, Ohmmeters. |
| 8 | 7085A | Auto Switching Temperature Distribution Module | Allows 7 thermocouple types to be batch calibrated as well as providing an RTD reference. |
| 9 | 7059/7101 | Vacuum/Pressure Calibrator (VAC + 2bar) | Allows vacuum and low range pressure instruments, switches, gauges transmitters, transducers to be calibrated. |
| 10 | 7062/7102 | Pressure Calibration module with regulator (5bar) | Allows calibration of mid range pressure devices. |
| 11 | 7032/7103 | Semi-Automatic Pressure Calibration module with regulators (10bar) | Allows set point calibration of mid range pressure devices. |
| 12 | 7062/7104 | Pressure Calibration module with regulator (20bar) | Allows calibration of mid range pressure devices. |
| 13 | 7064/7107 | High Pressure Calibration module with regulator (100bar) | Allows calibration of high range pressure devices. |
| 14 | 7064/7108 | High Pressure Calibration module with regulator (200bar) | Allows calibration of high range pressure devices. |
| 15 | 7066/7102 | Differential Pressure Calibration module (5bar) | Allows calibration of differential pressure instrumentation below 5bar. |
16 | 7066/7103 | Differential Pressure Calibration module (10bar) | Allows calibration of differential pressure instrumentation below 10bar. |
17 | 7038/7109 | Multi Function Pressure Indicator (400bar) | Additional high pressure indication. Used for calibration with the 7195 hydraulic pump input. |
18 | 7038/7110 | Multi Function Pressure Indicator (600bar) | Additional high pressure indication. Used for calibration with the 7195 hydraulic pump input. |
19 | 7198 | Multi Adaptors/Fittings Kit with case | Provides all the required pressure connections and fittings for modules and pumps. |
20 | 7149 | Electrical Vacuum Pump | To supply the 7059 module a vacuum pressure source. |
| 21 | 7194 | Desktop Pneumatic Pump (Vacuum to 100bar) | For manual pressure generation up to 100bar |
| 22 | 7094 | Digital Pressure Gauge (0 to 100bar, 0.25% Accuracy) | Secondary reference (back up or field use). |
23 | 7195 | Benchtop Hydraulic Pump (0 to 600bar) | Provides pressure input to the 7038 modules up to 600bar. |
24 | 7096 | Digital Pressure Gauge (0 to 700bar, 0.25% Accuracy) | Secondary reference (back up gauge). |
25 | 7072 | Dry Block Calibrator (33 to 650 degC) | For calibrating temperature probes, RTDs, and more. |
26 | CERTS | Factory Calibration Certificates for test modules | Certifies all calibration modules have been tested in the TE factory (NPL traceable). |
The CalBench Auto Process Package can be customised per requirement. Options include:
• Replacing or removing non-required modules. Add others from the TE CalBench range.
• Additonal external items for other calibration applications: Electronic, electrical, dimensional, torque, weight, etc
• Line pressure requirements: This system can use up 200bar line pressure. Hand pumps can also be used (7194 and 7195) or compressors and boosters can be supplied.
• Additional fittings and furniture: Under worktop drawers and cabinets, PC holders. Also side tables and laboratory furniture.
• Software add-ons and licenses: For customers requiring additional EasyCal features and workstation licenses.
• Laboratory design and supply: For the turnkey solution to design, install, commission, and train end users.
• CalBench Training: On-site or at the Time Electronics factory, UK.
The CalBench Pneumatic Pressure Package is a system built for calibrating pressure instrumentation under 200bar. The system includes pressure modules that require line pressure via the rear of the bench. In addition an external PC is used with EasyCal software for control of the 5065B digital multimeter module and communication/readback from pressure modules.
Calibrate these common devices/instruments and much more:
• Pressure: Gauges, Calibrators, Transducers, Transmitters, Indicators, Switches, Valves.
| Pneumatic Pressure CalBench Package (Order Code: CBPPP) |
|---|
| Item# | Code | Description | Purpose |
|---|---|---|---|
| 1 | 7080 | CalBench (W2000 x D850 x H1568): Height adjustable bench frame, work top, primary console with 7082 mains power control and distribution module (incl. 2 x output sockets), 4 x under console sockets, and under console lighting. | Provides an ergonomic workspace for various calibration and testing applications. A wide range of modules can be fitted to the primary console creating a highly flexible system that is both functional and easy to use. |
2 | 7125 | Under worktop PC holder (vertical) | For housing PC. |
| 3 | 7125 | 20 piece tool hook kit for rear perfo panel | For holding various instruments, devices and tools. |
| 4 | 7087 | Quad DC Power Supply Module - 6V(8A), 12V(8A), 24V(4A), 48V(3A) | Provides a DC power supply to various loop instrumentation under test. |
| 5 | 7053 | 56V DC 4A Adjustable Power Supply Module - Digital | Provides a variable precision DC power supply for a various applications. |
| 6 | 5065B | 6.5 digit multimeter | Provides measurement capabilities for transducers and transmitters under test. |
| 7 | 7059/7101 | Vacuum/Pressure Calibrator (VAC + 2bar) | Allows vacuum and low range pressure instruments, switches, gauges transmitters, transducers to be calibrated. |
| 8 | 7062/7103 | Pressure Calibration module with regulator (10bar) | Allows calibration of mid range pressure devices. |
| 9 | 7062/7104 | Pressure Calibration module with regulator (20bar) | Allows calibration of mid range pressure devices. |
| 10 | 7064/7107 | High Pressure Calibration module with regulator (100bar) | Allows calibration of high range pressure devices. |
| 11 | 7064/7108 | High Pressure Calibration module with regulator (200bar) | Allows calibration of high range pressure devices. |
| 12 | 7066/7102 | Differential Pressure Calibration module (5bar) | Allows calibration of differential pressure instrumentation below 5bar. |
13 | 7066/7103 | Differential Pressure Calibration module (10bar) | Allows calibration of differential pressure instrumentation below 10bar. |
14 | 7198 | Multi Adaptors/Fittings Kit with case | Provides all the required pressure connections and fittings for modules. |
15 | 7194 | Desktop Pneumatic Pump (Vacuum to 100bar) | For manual pressure generation up to 100bar |
16 | 7094 | Digital Pressure Gauge (0 to 100bar, 0.25% Accuracy) | Secondary reference (back up or field use). |
17 | 7149 | Electrical Vacuum Pump | To supply the 7059 module a vacuum pressure source. |
18 | CBPC | PC with monitor, keyboard & mouse (not required if existing PC is used). Unit includes an 8 way port for RS-232 connectivity to modules. Note that the monitor can be mounted on a side arm from the bench if required. | Configured with EasyCal, the PC workstation provides storage management for QMS data and includes instrument user manuals, company protocols and policies. The workstation can also be connected to a local network for information sharing, backup and remote maintenance. |
19 | ECFLA | EasyCal Calibration Software Suite (pre-loaded on CBPC if ordered) | Software to provide automated calibration run for bench instruments and complete workflow for management of calibration standards, management of instruments, Job report and Job data capture, Calibration due reminder system, ID and bar code printing, PDF reports and certificates as well as simulation mode and over 1200 standard calibration procedures to get started. |
20 | 9795 | Printer and Connectivity Kit - Includes InkJet Printer, DVD-RW, 4 Port USB Hub, Numeric Key Pad & USB Memory Stick | Allows certificates and reports to be printed as required. Also data storage and connectivity. |
21 | 9777 | Bar Code Reader | For reading instruments/devices that have been bar coded. Enables instant identification within EasyCal. |
22 | 9778 | Cal and ID Label Printer | Print calibration labels, bar codes, and ID labels for tagging devices and instruments. |
23 | 9796 | Premium Test Lead Set | Provides necessary connections for the 5065B DMM module. |
| 24 | CERTS | Factory Calibration Certificates for test modules | Certifies all calibration modules have been tested in the TE factory (NPL traceable). |
The CalBench Pneumatic Pressure Package can be customised per requirement. Options include:
• Replacing or removing non-required modules. Add others from the TE CalBench range.
• Additonal external items for other calibration applications: Electrical, electronic, process, dimensional, torque, weight, etc
• Line pressure requirements: This system can use up 200bar line pressure. 7194 benchtop pump can be used (120bar max) or compressors and boosters can be supplied.
• Additional fittings and furniture: Under worktop drawers and cabinets, PC holders. Also side tables and laboratory furniture.
• Software add-ons and licenses: For customers requiring additional EasyCal features and workstation licenses.
• Laboratory design and supply: For the turnkey solution to design, install, commission, and train end users.
• CalBench Training: On-site or at the Time Electronics factory, UK.
The CalBench Electrical/Electronic Package is for test facilities requiring a multi-product calibration solution for testing mainly electronic devices and instruments. Items have been carefully selected to provide a range of comprehensive features to enhance and optimise the calibration process.
Using the 7051 temperature and loop calibration is also possible.
Calibrate these common devices/instruments and much more:
• Electrical/Electronic: Multimeters, AC/DC Signal Sources, Clamp Meters, Tachometers, Ohmmeters, Decade Boxes, Power Supplies.
• Temperature and Loop: Sensors, Indicators, Thermocouple and RTD Transmitters, Calibrators, PRTs, Thermistors.
• Frequency: Signal Generators, Oscilloscopes, Frequency Meters, Timer Counters.
| Item# | Code | Description | Purpose |
|---|---|---|---|
1 | 7080 | CalBench (W2000 x D850 x H1568): Height adjustable bench frame, work top, primary console with 7082 mains power control and distribution module (incl. 2 x output sockets), 4 x under console sockets, and under console lighting. | Provides an ergonomic workspace for various calibration and testing applications. A wide range of modules can be fitted to the primary console creating a highly flexible system that is both functional and easy to use. |
| 2 | 7121 | 2 drawer Unit (W500 x D550 x H250mm) | For general use and keeping documents etc |
3 | 7087 | Quad DC Power Supply Module - 6V(8A), 12V(8A), 24V(4A), 48V(3A) | Provides a DC power supply to various loop instrumentation under test. |
4 | 7053 | 56V DC 4A Adjustable Power Supply Module - Digital | Provides a variable precision DC power supply for a various applications. |
5 | 7088 | Adjustable AC Supply Module (0 - 265V/10A at 240V input or 0 - 121V/10A at 110V input) | Provides a variable AC supply to electrical/electronic DUT’s |
6 | 7051+ | Multifunction Calibrator & Control Centre Module: • Integral calibrator, 6.5 digit DMM, touch screen PC • Source up to 1050V AC/DC voltage • Sourceup to 22A AC/DC current • Source up to 1GΩ resistance • Thermocouple simulate and measure • PT100 simulate and measure • Source capacitance and inductance • Oscilloscope calibration • Clamp meter adaptor & tacho meter adaptor • EasyCal calibration software, printer kits, bar code reader and more extras included | Allows automated calibration for a wide range of electronic test, pressure, temperature and electrical instrumentation. Provides precision electronic calibration source and measurement functions to calibrate a wide range of digital and analogue multimeters, frequency meters, ohm meters, AC/DC millivoltmeters, decade boxes, thermocouple indicators and sensors, clamp meters, oscilloscopes, timer counters, RTDs. Further to this it provides communication with pressure modules.
EasyCal enables the user to automate the calibration process and increase speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards. |
7 | 9769 | 7051 internal option: Scope 2.2GHz Levelled Sine Generator | Enhances the 7051's oscilloscope calibration capabilities. |
8 | 5068B | Insulation Tester Calibration Module | Allows insulation testers to be calibrated (up to 2.5kV). |
9 | 9758B | DC Electronic Load Module, 80A, 80V, 300W | Provides a precision controlled DC load for calibrating DC power supplies. |
| 10 | 7139 | Shelf (W450 x D250 x H130mm) for rear perfo panel | Suitable for holding portable equipment and tools |
| 11 | 7143 | Document Holder (W450 x H360mm) for rear perfo panel | For holding user manuals of DUTs and other documentation |
| 12 | 7145 | Benchtop Solder Station and Rework Kit | High quality soldering, for electronics, components etc. Extras also available such as fume extractor and circuit board holders. |
| 13 | 7183 | Electronics service case (82 tools) | General use, highly practical for various lab requirements |
| 14 | CERTS | Factory Calibration Certificates for test modules | Certifies all calibration modules have been tested in the TE factory (NPL traceable) |
The CalBench Electrical/Electronic Package can be customised per requirement. Options include:
• Replacing or removing non-required modules. Add others from the CalBench range: Oscilloscopes, frequency counters, signal generators and more.
• Additonal external items for other calibration applications: Process, pressure, dimensional, torque, weight, etc
• Additional fittings and furniture: Under worktop drawers and cabinets, PC holders. Also side tables and laboratory furniture.
• Software add-ons and licenses: For customers requiring additional EasyCal features and workstation licenses.
• Laboratory design and supply: For the turnkey solution to design, install, commission, and train end users.
| PDF Downloads |
|---|
| File Name | File Size | Language |
|---|---|---|
2.3MB | EN |