Home |
Products
List all products
List all products
1006 DC Millivolt Source
- 3 ranges up to 1V
- 0.02% accuracy
- 20mA output current
- Short circuit/overload protection
- Safety terminals
- 100 hours typical battery life
- Supplied with protective cover
1007 DC Millivolt Potentiometer & Calibrator
- 3 ranges up to 1V
- 0.02% accuracy
- 20mA output current
- Short circuit/overload protection
- LED null measuring facility
- 100 hours typical battery life
- Portable with protective cover
1010 DC Voltage Calibrator
- 0.01μV to 10V in 5 ranges
- 0.02% accuracy
- Battery or mains operation
- 30mA output current
- 10ppm/hr stability
- Battery level indicator
- Safety terminals
1017 Voltage/Current/Resistance Calibrator
- DC Volts 10nV to 100V
- DC Current 100nA to 100mA
- Resistance 10mΩ to 10kΩ
- 0.005% (50ppm) accuracy
- 1 ppm setting resolution
- Noise <2ppm (0.1 to 1Hz)
- Stability <5ppm/day, <25ppm/yr
1021 DC Current Source
- 0 to 100mA in 3 ranges
- 0.02% accuracy
- 25ppm/hr stability
- Up to 40V output drive
- LED null measuring facility
- Safety terminals
- Supplied with protective cover
1024 DC Current Calibrator
- 0 to 100mA output in 5 ranges
- 0.02% accuracy
- 10ppm/hr stability
- Up to 15V output drive
- Null measuring facility
- Safety terminals
- Battery or mains operation
1030 Voltage and Current Source
- 10mV, 100mV, 1V ranges
- 10mA, 100mA ranges
- 0.1% accuracy
- 0 to 8V available
- Precision 10-turn dial
- Battery level indicator
- Battery powered 9V PP3
1040 - 8 Decade Resistance Box
- 1Ω to 100MΩ
- High accuracy
- Clear visual indication
- High stability
- Safety terminals
- Low temperature coefficient
- Supplied with protective cover
1041 - 5 Decade Resistance Box
- 0.01Ω to 1kΩ
- 10mΩ resolution
- Ideal for PRT/RTD
- High stability
- Safety terminals
- Low temperature coefficient
- Supplied with protective cover
1044 Voltage and Current Calibrator
- Measure voltage and current
- Source voltage and current
- 0.05% accuracy
- 0 to 20V in 3 ranges
- 0 to 20mA in 3 ranges
- Battery power 9V PP3
- Portable with carry case
1048 Voltage/Current/Loop Calibrator
- Source/measure current & voltage
- 3 Source ranges to 22mA or 22V
- 3 Measure ranges to 70mA or 50V
- Transmitter simulator/sink
- Output steps and ramps
- Fine adjustment (inching)
- Accuracy 0.02% of span
1049 PT100 Simulator
- -200°C to + 800°C
- ± 0.3°C accuracy
- Based on ITS 90 EN60751
- 23 set points
- Exceeds class A
- Good temperature stability
- Passive resistance source
1050 PT100 Simulator
- -100°F to + 1000°F
- ± 0.5°F accuracy
- Based on ITS 90 EN60751
- 23 set points
- Exceeds class A
- Good temperature stability
- Passive resistance source
1051 - 8 Decade Resistance Box
- 0.01Ω to 1MΩ
- High accuracy & stability
- Clear visual indication
- Safety terminals
- Low temperature coefficient
- Suitable for PRT/RTD
- Supplied with protective cover
1053 - 4 Decade Inductance Box
- 1mH to 10H
- In-line readout
- 3% accuracy
- High stability
- Safety terminals
- Fully screened
- Robust and portable
1061 - 6 Decade Resistance Box
- 1Ω to 1.2MΩ
- In-line readout
- Stable metal film resistors
- Mechanically/electrically robust
- Safety terminals
- Fully screened
1065 - 6 Decade Power Resistance Box
- 0.1Ω to 120kΩ
- 1% accuracy
- 10W per resistor dissipation
- Residual resistance < 20mΩ
- In-line readout
- Mechanically/electrically robust
- Fully screened
1067 - 6 Decade Precision Resistance Box
- 10mΩ to 12kΩ
- 0.01% accuracy
- Precision PT100 simulation
- 6 digit resolution
- Better than 20ppm/year stability
- Residual resistance < 10mΩ
- Fully screened
1068 - 5 Fixed Resistance Box
- 5 fixed resistance ranges
- High accuracy
- Clear visual indication
- Portable and compact
- Simple operation
- Robust casing
- Ideal for education
1070 - 5 Decade Capacitance Box
- 100pF to 10μF
- 1% Accuracy
- In-line readout
- Colour coded digits
- Safety terminals
- Bi-polar working
- Supplied with protective cover
1071 - 7 Decade Capacitance Box
- 10pF to 100μF
- 1% accuracy
- In-line readout
- Colour coded digits
- Safety terminals
- Bi-polar working
- Supplied with protective cover
1077 Milliamp Transducer Simulator
- 3 operating modes
- 100mA source and load
- 24V line mode
- 0.02% accuracy
- Safety terminals
- Battery level indicator
- Supplied with protective cover
1090 Portable Process Calibrator
- Measure/simulate thermocouples
- Measure/simulate PT100
- Measure/source (µV/mV/mA)
- Display in °C and °F
- Automatic CJC - selectable
- 10 point memory recall
- Process loops 4-20mA/0-50mA
5011 Resistance / Temperature Calibrator
- 1Ω to 120MΩ
- RTD & thermocouple simulation
- DCV and DCI options
- 10MHz frequency option
- RS-232 / GPIB / USB interfaces
- Front panel operation
- EasyCal Software compatible
5018 Programmable DC/AC V/I Calibrator
- 0 - 22V DCV (30V DC optional)
- 0 - 22V AC, 220V & 1kV DC options
- Optional 0 - 220mA AC/DC
- Ramping feature
- GPIB / RS-232 / USB interfaces
- Ideal for ATE applications
- EasyCal Software compatible
5025 Multifunction Calibrator
- 0 - 1050V & 0 - 22A (AC/DC)
- 1Ω to 1GΩ resistance
- Thermocouple simulation
- Oscilloscope calibration option
- PT100, C & L, and power options
- Clamp meter calibration
- EasyCal software compatible
5025E Multifunction Calibrator
- 0 - 1050V & 0 - 22A (AC/DC)
- 10Ω to 1GΩ resistance
- Thermocouple & PT100 simulation
- Digital frequency
- Optional clamp meter calibration
- Scope and power options
- EasyCal software compatible
5030 Electrical Tester Calibrator
- RCD: 3 - 2500mA, 10 - 2000ms
- Loop 50mΩ to 1.8kΩ
- Insulation up to 2GΩ / 1kV
- Continuity 0.1Ω to 10kΩ
- RS-232 / USB Control
- Fast and intuitive user interface
- EasyCal software compatible
5033 3 Channel DC Power Source
- 3 independent channels
- 0 to 20V DC 2A drive capability
- 40 watts max per channel
- 10μV resolution setting
- Programmable via GPIB interface
- Easy to use command language
- 4 Terminal Output
5045 Oscilloscope Calibrator
- 10mV to 220V square wave/DC
- Frequency 0.1 to 100MHz
- Time markers 10s to 10ns
- Fast rise <300ps
- Front panel or PC control
- 2GHz sweep & rubidium options
- EasyCal software compatible
5051Plus Multifunction Calibration System
- Combined calibrator/DMM/PC
- 0 - 1050V & 0 - 22A (AC/DC)
- Source up to 1GΩ resistance
- Thermocouple simulate/measure
- PT100, C & L, scope calibration
- Clamp meter calibration
- EasyCal Software included
5065 6.5 digit Multimeter
- Resolution 6 1/2 digits
- Accuracy: 0.005% DC voltage
- USB interface
- Optional GPIB interface
- Temperature measurements
- 10 channel scanner option
- EasyCal software compatible
5068 Insulation Tester Calibrator
- 100KΩ to 10GΩ
- Basic accuracy 1%
- Up to 2.5kV operation
- Battery operation
- Fully shrouded safety connectors
- Display of open circuit voltage
- Display of short circuit current
5069 Insulation Tester Calibrator
- 100KΩ to 100GΩ
- Basic accuracy 1%
- Up to 10kV operation
- Battery operation
- Fully shrouded safety connectors
- Display of open circuit voltage
- Display of short circuit current
5070 Micro-ohm Meter Calibrator
- Calibrate ductor testers
- Calibrate micro-ohm meters
- 0.2, 2, 20, 200, 2000mΩ
- 5 cal points: 0/25/50/75/100%
- Gold plated terminals
- Low thermal emf connection
- Portable robust carrying case
5075 7.5 digit Multimeter
- 7½ digit resolution
- AC/DC voltage & current
- Resistance & temperature
- Capacitance & frequency
- 18ppm/year accuracy
- 10 channel scanner option
- EasyCal software compatible
5077 Power Calibrator
- 20mA to 22A AC/DC
- 100A AC I transformer option
- 1mV to 1050V AC/DC
- +90.0 deg to -90.0 deg
- 0.00 to 1.00 Lead/Lag
- 45 to 400 Hz in 0.1Hz steps
- RS-232 / GPIB / USB interface
5080 PAT Calibrator
- Calibrate PATs & VDE0701 testers
- Battery powered
- LCD display of voltage & current
- Safety interlock feature
- Earth bond currents up to 50A AC
- Load test currents up to 13A AC
- Impact resistant case
7000 RTD Temperature Calibrator
- 0.05°C accuracy, 0.01°C resolution
- 0.03Ω accuracy, 0.01Ω resolution
- 2, 3 and 4 wire connections
- Read and simulate °C, °F, °K, Ω
- Ramp and step
- PT100 plus 7 other RTD types
- User programmable
7005 Voltage/Current/Loop Calibrator
- Loop source/measure - V or I
- Measure 0 - 25V or 0 - 125mA
- Source 0 - 21V or 0 - 50mA
- Accuracy 0.01%
- Resolution 1μA or 1mV
- Programmable ranges
- Manual step, auto-step & ramp
7006 Loop Simulator & Source
- 4 - 20mA or 0 - 10V loops
- 7 calibration set-points
- Accuracy 0.1%
- TxSim and RxTest modes
- Autostep output - adjustable rate
- Battery powered PP3
- Internal loop drive supply
7007 Loop Signal Indicator
- 4 - 20mA, 0 -10V, 0 - 50V ranges
- LCD 4 digit display, mA, V, % of rng
- Accuracy 0.05%
- RxSim, TxTest, or 50mA/50V modes
- Internal loop supply, 25mA max
- Battery powered 9V PP3
- Supplied with carry case
7010 Single Channel Pressure Calibrator
- Vacuum to 600bar versions
- Accuracy 0.04% of full scale
- Pneumatic or hydraulic
- Over-pressure alarm
- Isolated 24/36V loop supply
- Loop current measure
- Mains / battery power
7015 Dual Channel Pressure Calibrator
- Vacuum to 600bar versions
- Accuracy 0.04% of full scale
- Pneumatic or hydraulic
- Over- pressure alarm
- Isolated 24/36V loop supply
- Loop current measure
- Mains / battery power
7016 Regulated Low Pressure Calibrator
- Regulated low pressure
- Vacuum to 20bar versions
- Accuracy 0.04% of full scale
- Pneumatic
- Isolated 24/36V loop supply
- Loop current measure
- Mains / battery power
7018 Differential Pressure Calibrator
- Vacuum, 0.2, 2, 5 & 10bar versions
- Accuracy 0.04% of full scale
- Pneumatic
- Over-pressure alarm
- Isolated 24/36V loop supply
- Loop current measure
- Mains or battery powered
7040 Digital Pressure/Current Calibrator
- Vacuum to 20bar versions
- 0.04% accuracy
- Loop current calibration
- 9 engineering units
- Min / Max function
- Leak rate function
- RS-232 serial interface
7050 Process and Thermocouple Calibrator
- 3 ranges to 40V, 400mA, 40kΩ
- O/p volt. up to 10V, 1uV resolution
- O/p I up to 20mA, 1uA resolution
- O/p R: 0-400Ω, 0.01Ω resolution
- Thermocouple measure & simulate
- RTD measure & simulate: PT100
- Battery / mains operation
7078 Auto-Ranging Digital Pressure Gauge
- Vacuum to 200bar (3000psi)
- Accuracy 0.1% of reading
- 9 engineering units
- Silicone piezo resistive sensors
- Reads gauge & absolute pressure
- Easy to read backlit colour display
- Robust with protective rubber boot
7090 Pneumatic Calibration Pump
- Pressure to 40bar (600psi)
- Vacuum to -950mbar
- Oversized check valve
- Contoured cushioned handles
- Protective caging for vent valve
- Hose, fittings, & carry case supplied
- Optional digital gauges
7091 Digital Pressure Gauge
- Vacuum to 40bar (600psi)
- Accuracy 0.2% of full scale
- Easy-to-read display
- 5 digit resolution
- 3 times per second measure speed
- Analogue dial indicates % pressure
- Ideal for use with the 7090 pump
7093 Precision Loop and Dual Pressure Calibrator
- Vacuum to 600bar versions
- Pressure accuracy 0.04% of FS
- 0.025% high accuracy versions
- Pneumatic or hydraulic
- I measure: 125mA, Source: 50mA
- V measure: 25V, Source: 21V
- V/I accuracy 0.01%
7094 Digital Pressure Gauge
- 0 to 100bar (1500psi) pressure
- Accuracy 0.2% of full scale
- Easy-to-read display
- 5 digit resolution
- 3 times per second measure speed
- Analogue dial indicates % pressure
- Ideal for use with the 7194 pump
7095 Hydraulic Calibration Pump
- 0 to 700bar (10,000psi)
- Priming feature for fast air purge
- Oversized check valve
- Contoured cushioned handles
- Built-in pressure relief valve
- Hose, fittings, & carry case supplied
- Optional digital gauge
7096 Digital Pressure Gauge
- Pressure up to 700bar
- Accuracy 0.2% of full scale
- Up to 5000 hours battery life
- Easy-to-read display
- 5 digit resolution
- 3 times per second measure speed
- Ideal for use with the 7095 pump
7194 Pneumatic Pressure Calibration Pump
- 0.95bar vacuum to 100bar (1500psi)
- Dual pressure source
- High pressure resolution
- High pressure stability
- Easy to use pressure lever/handle
- Free from humidity and dirt
- For reference calibration with gauge
7195 Hydraulic Pressure Calibration Pump
- 0.9bar vacuum to 600bar (8700psi)
- Dual pressure source
- High pressure resolution
- High pressure stability
- Smooth pressure generation
- Oil or deionized water
- For reference calibration with gauge
Calibration Benches
- Universal calibration systems
- Electrical/pressure/process
- Power supplies, DMMs & scopes
- 7051 MF calibrator/control module
- Ideal for on-site test facilities
- Automatic or manual calibration
- Complete lab design service
EasyCal Calibration Software
- Automate the calibration process
- Control TE calibrators & DMMs
- Automated planning & scheduling
- For use with multiple devices
- 1200+ cal procedures included
- Management/admin features
- Easily produce certificates & reports