A precision calibrator designed to provide rapid high accuracy calibration of portable appliance testers and insulation/continuity testers.
The 5080 has calibration functions for earth bond, insulation, leakage, touch leakage, and load test.
Housed in a robust safety case the 5080 is easily portable and ideal for field calibration work. It is battery powered, which ensures isolation and prevents inaccuracies due to stray leakage. Features include safety interlock that prevents contact with earth bond studs during insulation and leakage tests, and an LCD display for voltage and current.
| Earth Bond: Calibrated low value resistive loads |
|---|
Values / Accuracy |
20mΩ, accuracy 5% |
Open circuit voltage measurement |
Range: 0 to 20V |
High current AC measurement |
Range: 0 to 50A AC |
Low current AC measurement |
Range: 0 to 2A AC |
Low current DC measurement |
Range: 0 to 2A DC |
| Insulation: Calibrated high value resistive loads |
|---|
Values / Accuracy |
95kΩ, 105kΩ, 500kΩ, 950kΩ, 1.05MΩ, 5MΩ, 10MΩ, accuracy 0.1% |
Open circuit voltage measurement |
Range: 0 to 1kV DC |
| Current measurement | Range: 0 to 20mA DC. Accuracy: 0.25% of full scale |
| Leakage: Resistive loads for leakage current |
|---|
| Nominal Leakage Currents | At 230V AC of 0.5, 1, 2, 5, 10, 15mA |
Mains voltage measurement |
Range: 0 to 500V AC |
Leakage current measurement |
Range: 0 to 20mA AC |
| Touch Leakage: Constant current source for touch leakage meters |
|---|
| Current | 1.9mA AC 50 +/-5 Hz, into 2K2 maximum load resistance |
| Current measurement | Range: 0 to 2mA AC. Accuracy: 0.25% of full scale |
| Load Test: Connection of external load via an IEC connector |
|---|
Mains voltage measurement |
Range: 0 to 500V AC |
Load current measurement |
Range: 0 to 13A AC |
| Power | Internal battery 6V re-chargeable NiCad, >200 hrs between charges. |
| Dimensions | W406 x H175 x D330mm |
| Weight | 5.5kg |
| Supplied With | 4mm terminal box adaptor, 110V adaptor, IEC connector (for external load), battery charger, and user manual. |
| Optional Extras | Calibration certificates traceable NPL and UKAS |
| Country of Origin | UK |
| Models |
|---|
5080 |
PATCAL – Portable Appliance Tester Calibrator |
| Options |
|---|
| C188 | Factory Calibration Certificate (NPL traceable) |
| C135 | UKAS Calibration Certificate (ISO 17025) |
| PDF Downloads |
|---|
| File Name | File Size | Language |
|---|---|---|
225kB | EN |